Derivative after liquid phase column

NegotiableUpdate on 01/09
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The T15 liquid phase column derivative system produced by our company has stable quality and high cost-effectiveness, and has been used by more than 100 customers in China. The system consists of two SHU liquid pumps and a secondary derivative system, which comply with standards such as "Detection of Carbamate Pesticide Residues in Fruits and Vegetables", "Detection of Glyphosate and Furan in Drinking Water", and detection of Aspergillus flavus
Product Details

1Derivative after liquid phase columnSystem features:

1. In order to ensure the key performance indicators of the instrument, all core components of the reagent pump are made of advanced imported parts, and the proportion of imported parts in the entire instrument reaches over 80%; The main indicators that determine the SHU liquid pump are * * high pressure indicators, and all sealing system components of Huameichen Company are imported from the United States. The motor drive that determines the stability and accuracy of flow is imported from Japan. The pulsation damper that suppresses pulsation is a proprietary design of Huameichen Company.

2. The derivative system adopts imported derivative pipelines and flow limiters to ensure the stability of the baseline and the separation degree of each measured substance.


IIDerivative after liquid phase columnSystem technical parameters:

1P15 high-pressure SHU liquid pump

- Flow range: 0.001ml/min~10ml/min

- Flow accuracy:<0.5% (0.5ml/min~10ml/min)

- Flow stability: RSD ≤ 0.06%

- * * High pressure resistance: 42MPa

Imported motor, imported driver, no mechanical noise, ensuring accuracy

Imported sealing system with strong high pressure resistance

Imported high-efficiency pulsation damper with strong buffering capacity, making pulsation * * small

- Fully imported liquid pipeline

- Safety control: pressure upper and lower limit control, buzzer alarm, automatic shutdown

2T15 chromatography column post derivatization device

- Advanced microprocessor chip, high-sensitivity temperature sensor, can achieve temperature setting and control accuracy of ± 0.1 ℃ and maintain stability continuously

- Temperature range: Room temperature~150 ℃

- Setting accuracy: ± 0.1 ℃

- Equipped with sealed 10 meter or 20 meter imported derivative liquid pipeline


3、 Analysis project:

- Detection of pesticide residues in insecticides (amino acid esters)

- Various toxins (such as aflatoxin, vomitoxin, shellfish toxin, etc.)

- Detection of herbicide residues (such as glyphosate, Diclofenac, etc.)

- Drug analysis (Vogt LIE polysaccharide, HONG mycin, etc.)

- Amino acid analysis (amino acids, taurine)

Amino acid glycosides, polyether antibiotics

- Urine/wind diabetes testing and screening

Other substances such as biogenic amines, bromate, formaldehyde, chromium VI, guanidine