The portable dissolved oxygen analyzer DO-810 (fluorescence method) for Shenchanghong water quality monitoring has functions such as computer program control calibration, automatic temperature compensation, salinity correction, and atmospheric pressure adjustment, suitable for measuring oxygen content in aqueous solutions in various industries. The instrument adopts ultra-low power microcontroller for measurement and control, and uses fluorescence method for measurement. It has the advantages of stability, reliability, simple and convenient operation, etc; This instrument can indicate the measurement results in two units of dissolved oxygen content, namely oxygen concentration (mg/L) and oxygen saturation percentage (%). In addition, it also measures and displays the temperature (℃) of the measured medium.

Portable dissolved oxygen analyzer for water quality monitoring (fluorescence method)
This instrument has computer program controlled calibration, automatic temperature compensation, salinity correction, and atmospheric pressure adjustment functions, suitable for measuring oxygen content in aqueous solutions in various industries.
【 Working Principle 】
Portable dissolved oxygen analyzer for water quality monitoring (fluorescence method)_DO-810 portable dissolved oxygen meterUsing ultra-low power microcontroller for measurement and control, and fluorescence method for measurement. It has the advantages of stability, reliability, simple and convenient operation, etc; This instrument can indicate the measurement results in two units of dissolved oxygen content, namely oxygen concentration (mg/L) and oxygen saturation percentage (%). In addition, it also measures and displays the temperature (℃) of the measured medium.
1. High performance and ultra-low power consumption16 bit microcontroller, equipped with high-capacity rechargeable lithium battery.
2. LCD large screen LCD Chinese character menu display, easy and intuitive operation.
3. Good anti-corrosion, waterproof and dustproof performance.
4. One or two point calibration, saturation percentage calibration.
5. Temperature compensation.
6. The salinity coefficient and atmospheric pressure can be set.
7. The electrode has a long service life.
8. CanStore 300 sets of data.
9. Data power-off protection function, equipped with Type-C port, can be connected to a computer for data transmission.
Instrument name |
Portable precision dissolved oxygen analyzer |
Instrument model |
DO-810
|
sensorComponent Description |
*Immersive probe |
sensorStorage temperature(T) |
-40~85℃ |
Probe cable length |
2m |
sensor drift |
<1% per year |
Minimum turning radius of cable |
15mm |
Fluorescent cap lifespan |
One year (under normal usage) |
measurement range |
溶氧 (DO):0.0~20.0mg/L OR 0 ~200 %
Temperature (T): 0-50 ℃
|
measurement accuracy |
Dissolved oxygen: ± 0.2mg/L (isothermal between the tested system and the calibration system); ± 0.5mg/L (maximum allowable drift)
Temperature (T): ± 1 ℃
|
Temperature compensation range |
0~50℃ |
calibration point |
1 or 2-point calibration, saturation percentage calibration (for high-altitude areas). |
Salinity compensation setting |
0~35g/L, The default salinity is 0, in ppt units. Usually fresh water is 0-0.5ppt, and seawater is 35ppt. |
Atmospheric pressure setting |
0.5 to 1.5 atmospheres |
power supply |
Rechargeable lithium battery 7.4V 1500mAh |
Overall dimensions |
185mm x 92mm x 50mm (length x width x height) |
weight |
About 370g |
Table 1 Saturation Content of Oxygen in Water at Different Temperatures
Note: Saturated oxygen needs to be exposed to air in water using an aerator pump for 15 minutes, and the water after removing the aerator pump is saturated. If conditions do not permit, it can be assumed that the air is in a saturated oxygen environment.
temperature |
Dissolved oxygen mg/L |
temperature |
Dissolved oxygen mg/L |
temperature |
Dissolved oxygen mg/L |
0 |
14.64 |
14 |
10.30 |
28 |
7.82 |
1 |
14.22 |
15 |
10.08 |
29 |
7.69 |
2 |
13.82 |
16 |
9.86 |
30 |
7.56 |
3 |
13.44 |
17 |
9.66 |
31 |
7.43 |
4 |
13.09 |
18 |
9.46 |
32 |
7.30 |
5 |
12.74 |
19 |
9.27 |
33 |
7.18 |
6 |
12.42 |
20 |
9.08 |
34 |
7.07 |
7 |
12.11 |
21 |
8.90 |
35 |
6.95 |
8 |
11.81 |
22 |
8.73 |
36 |
6.84 |
9 |
11.53 |
23 |
8.57 |
37 |
6.73 |
10 |
11.26 |
24 |
8.41 |
38 |
6.63 |
11 |
11.01 |
25 |
8.25 |
39 |
6.53 |
12 |
10.77 |
26 |
8.11 |
|
|
13 |
10.53 |
27 |
7.96 |
|
|
Appendix 2 Table of correspondence between altitude and atmospheric pressure
|
Altitude h
(m)
|
atmospheric pressure
(atm)
|
Altitude h
(m)
|
atmospheric pressure
(atm)
|
0 |
1.000 |
1100 |
0.872 |
100 |
0.988 |
1200 |
0.861 |
200 |
0.975 |
1300 |
0.850 |
300 |
0.963 |
1400 |
0.839 |
400 |
0.952 |
1500 |
0.829 |
500 |
0.940 |
1600 |
0.818 |
600 |
0.928 |
1700 |
0.808 |
700 |
0.916 |
1800 |
0.799 |
800 |
0.905 |
1900 |
0.789 |
900 |
0.893 |
2000 |
0.779 |
1000 |
0.883 |
2200 |
0.769 |
Packing list
serial number |
Name |
unit |
quantity |
Remarks |
1 |
host |
Taiwan |
1 |
|
2 |
oxygen electrode |
branch |
1 |
|
3 |
Instruction Manual |
copy |
1 |
|
4 |
Warranty Card |
copy |
1 |
|
5 |
Product Qualification Certificate |
copy |
1 |
|