COD Ammonia Nitrogen Total Phosphorus Total Nitrogen Analyzer Multi parameter Water Quality Number Detector $r $n Shenchanghong TMULP-3000 Multi parameter Water Quality Analyzer, can customize 1-16 channels, wavelength can be selected from the following: 340420440470520540560610630660700nm. The instrument automatically selects the wavelength; In addition, electrochemical parameters can also be customized among the following: temperature, PH, Conductivity, dissolved oxygen. $r $n can perform high-precision detection on nearly a hundred common parameters in water

working principle
The multi parameter water quality analyzer uses a single wavelength of light to pass through the test sample, and according to Lambert Beer's law, calculates the concentration value of a substance contained in the sample by measuring the absorbance value. Partial measurement parameters such as pH, conductivity, dissolved oxygen, temperature, etc. are measured using the (electrochemical) electrode method.
COD ammonia nitrogen total phosphorus total nitrogen analyzer, multi parameter water quality number detector Technical Specifications
Instrument name |
Multi parameter water quality analyzer |
Instrument model |
TMULP-3000 |
measurement items |
Customizable products (see "Measurement Item Table" below for details) |
Number of optical channels |
4/8/12/16, and if it is a customized product, 1-16 channels can be customized.
The wavelength can be selected from the following: 340420440470520540560610630680700nm.
The instrument automatically selects the wavelength. In addition, electrochemical parameters can also be customized among the following: temperature, PH, Conductivity, dissolved oxygen.
|
light source |
Imported high-performance LED |
| detector |
Silicon photoelectric sensor |
Wavelength accuracy |
Center wavelength ± 1nm |
Range of absorbance |
-2.000~2.000 |
Colorimetric linearity
|
±0.002A(0-1A) |
| Colorimetric accuracy |
±At 0.005A/1A |
repetitiveness |
≤2% |
Optical stability |
≤0.002A/20min |
Electrochemical method for determining parameters and ranges
|
Temperature: 0.0~100.0C;
Dissolved oxygen: 0.0~20.0mg/L;
PH:0.00~14.00PH;
Conductivity: 0.0ps/cm~2000.0ms/cm
|
| monitor |
Color touch screen, switching between Chinese and English
|
reading modes |
Concentration, absorbance, and transmittance |
Colorimetric method |
Colorimetric tube(F16mmTheФ25mm)And colorimetric dish |
Power supply |
AC220V(165V~240V),30W |
Instrument size |
400mm×300mm×140mm |
Instrument weight |
2.6kg |
Host power consumption |
<10W |
| working environment |
Temperature: 5~40C, humidity not exceeding 90% |
| storage environment |
Temperature: -40~60C, humidity not exceeding 90% |
COD ammonia nitrogen total phosphorus total nitrogen analyzer, multi parameter water quality number detector Product Features
●It can detect the concentration, absorbance, and transmittance of nearly a hundred parameters in water quality, and can store, print, query, and upload concentration values to a computer.
●Measure wavelengthAutomatic selection.
●The instrument adopts a large screen color touch screen operation, with a user-friendly interface and operation guide assistance to explain various functional operations
●In addition to a maximum of 250 factory curves, users can add 3500 curves themselves, calibrate them, and store them in the instrument.
●Store up to 100000 records (including parameter names, concentrations, units, detection times, operator numbers, etc.)
●The instrument measurement method can be either the straight line method or the line method. Choosing the line method can achieve more accurate measurement of some parameters with poor linearity.
●It has a one click recovery function, which can achieve one click recovery when the factory curve and user curve data records are lost due to accidents.
●The instrument can take backup measures for user calibrated curves and data records, and can be restored in case of accidental loss.
●The instrument comes with various security measures, including the ability to set startup and system settings with input passwords to prevent other personnel from accidentally operating the instrument settings.
●The light intensity can be adjusted, divided into 16 levels and set arbitrarily, which can effectively solve the problem of measurement range expansion caused by the strength of the signal.
●It is possible to query the curve, in addition to querying the curve equation, it is also possible to query the standard value and corresponding absorbance of each standard substance during calibration, as well as the calibration time and calibration personnel number, to reproduce the state during calibration.
●When recording queries, single item printing or page printing can be performed.
● The system has bilingual functionality and can switch between Chinese and English.
measurement items(Range expandable)
| serial number |
measurement items
|
Measurement range |
unit |
Accuracy (±) |
| 1 |
COD (chromium method)Low range) |
5-200 or 5-150 |
mg/L |
5% |
| 2 |
COD(铬法 高Range) |
200-2000 or 150-2000 |
mg/L |
5% |
| 3 |
Ammonia nitrogen (low range) |
0.02-5.00 |
mg/L |
3%(F.S) |
| 4 |
Ammonia nitrogen (high range) |
5.00-25.00 |
mg/L |
3%(F.S) |
| 5 |
Total phosphorus (low range) |
0.02-2.00 |
mg/L |
5%(F.S) |
| 6 |
Total phosphorus (high range) |
2.00-10.00 |
mg/L |
5%(F.S) |
| 7 |
Total nitrogen (low range) |
0.10-10 |
mg/L |
5%(F.S) |
| 8 |
Total nitrogen (high range) |
10-100 |
mg/L |
5%(F.S) |
| 9 |
CODMn(Permanganate Index |
0.00-10.00 |
mg/L |
0.2 or 5% |
| 10 |
Residual chlorine (low range) |
0.02~2.00 |
mg/L |
0.1 or 5% |
| 11 |
Residual chlorine (high range) |
2.00~10.00 |
mg/L |
5% |
| 12 |
Total chlorine (low range) |
0.02~2.00 |
mg/L |
0.1 or 5% |
| 13 |
Total chlorine (high range) |
2.00~10.00 |
mg/L |
5% |
| 14 |
Chlorine dioxide (low range) |
0.05~2.00 |
mg/L |
0.2 or 5% |
| 15 |
Chlorine dioxide (high range) |
2.00~20.00 |
mg/L |
5% |
| 16 |
sulfate |
5~200 |
mg/L |
5% |
| 17 |
Nitrate (nitrogen) |
0.02~10.00 |
mg/L |
0.1 or 5% |
| 18 |
Phosphate (low range) |
0.01~10.0 |
mg/L |
0.2 or 5% |
| 19 |
Phosphate (high range) |
10.0~50.0 |
mg/L |
5% |
| 20 |
Nitrite nitrogen (low range) |
0.02~1.0 |
mg/L |
0.05 or 5% |
| 21 |
Nitrite nitrogen (high range) |
1.0~5.0 |
mg/L |
5% |
| 22 |
sulfide |
0.005~1.000 |
mg/L |
5%(F,S) |
| 23 |
fluoride |
0.05~2.0 |
mg/L |
5%(F,S) |
| 24 |
Qing chemical compound |
0.01~0.50 |
mg/L |
5%(F,S) |
| 25 |
bromide |
0.10~5.00 |
mg/L |
5%(F,S) |
| 26 |
formaldehyde |
0.05~2.5 |
mg/L |
5%(F,S) |
| 27 |
Volatile phenols (low range) |
0.20~5.0 |
mg/L |
5%(F,S) |
| 28 |
Volatile phenols (high range) |
5.0~10.0 |
mg/L |
5%(F,S) |
| 29 |
hydrazine |
0.01~0.50 |
mg/L |
5%(F,S) |
| 30 |
Aniline compounds(Low range) |
0.03~1.0 |
mg/L |
5%(F,S) |
| 31 |
Aniline compounds(High range) |
1.0~5.0 |
mg/L |
5%(F,S) |
| 32 |
silicon dioxide |
0.01~5.00 |
mg/L |
5%(F,S) |
| 33 |
silicate |
0.01-5.00 |
mg/L |
5%(F,S) |
| 34 |
Total alkalinity (low range) |
0~100 |
mg/L |
5%(F,S) |
| 35 |
Total alkalinity (high range) |
100~1000 |
mg/L |
5%(F,S) |
| 36 |
Total hardness (low range) |
0.1~5.0 |
mg/L |
5%(F,S) |
| 37 |
Total hardness (high range) |
5.0~200.0 |
mg/L |
5%(F,S) |
| 38 |
Chloride ion (chloride) |
0.20-100.0 |
mg/L |
5%(F,S) |
| 39 |
ozone |
0.01~2.5 |
mg/L |
5%(F,S) |
| 40 |
Anionic surfactant |
0.01~1.0 |
mg/L |
5%(F,S) |
41
|
ammonium ion |
0.02~25.00 |
mg/L |
5%(F,S) |
| 42 |
available chlorine |
0.0~100.0 |
mg/L |
5%(F,S) |
| 43 |
chlorite |
0.00~20.00 |
mg/L |
5%(F,S) |
| 44 |
Cyanuric acid |
0~200 |
mg/L |
5%(F,S) |
| 45 |
urea |
0.00~4.00 |
mg/L |
5%(F,S) |
| 46 |
Copper (low range) |
0.02~1.0 |
mg/L |
5%(F,S) |
| 47 |
Copper (high range) |
1.0~10.0 |
mg/L |
5%(F,S) |
| 48 |
zinc
|
0.2~5.0 |
mg/L |
5%(F,S) |
49
|
Trace nickel (low range) |
0.02~0.50 |
mg/L |
5%(F,S) |
| 50 |
Trace nickel (high range) |
0.50~1.00 |
mg/L |
5%(F,S) |
| 51 |
nickel |
0.02~10.0 |
mg/L |
5%(F,S) |
| 52 |
Iron (low range) |
0.0~5.0 |
mg/L |
5%(F,S) |
| 53 |
Iron (high range) |
5.0~10.0 |
mg/L |
5%(F,S) |
| 54 |
Ferrous (low range) |
0.0~5.0 |
mg/L |
5%(F,S) |
| 55 |
Ferrous (high range) |
5.0~10.0 |
mg/L |
5%(F,S) |
| 56 |
hexavalent chromium |
0.01~1.00 |
mg/L |
5%(F,S) |
| 57 |
cadmium |
0.05~0.50 |
mg/L |
5%(F,S) |
| 58 |
Trace manganese (low range) |
0.01~0.10 |
mg/L |
5%(F,S) |
| 59 |
Trace manganese (high range) |
0.10~1.0 |
mg/L |
5%(F,S) |
| 60 |
manganese |
0.02~5.00 |
mg/L |
5%(F,S) |
| 61 |
Total chromium |
0.02~1.0 |
mg/L |
5%(F,S) |
| 62 |
Aluminum (low range)
|
0.01~0.40 |
mg/L |
5%(F,S) |
| 63 |
Aluminum (high range)
|
0.40~4.00 |
mg/L |
5%(F,S) |
| 64 |
silver |
0.01~1.00 |
mg/L |
5%(F,S) |
| 65 |
molybdenum |
0.05~1.00 |
mg/L |
5%(F,S) |
| 66 |
Arsenic (low range) |
0.004~0.100 |
mg/L
|
5%(F,S) |
| 67 |
Arsenic (high range) |
0.100~0.500 |
mg/L
|
5%(F,S) |
| 68 |
铍 |
0.001~0.10 |
mg/L |
5%(F,S) |
| 69 |
boron |
0.10~2.00 |
mg/L |
5%(F,S) |
| 70 |
mercury |
0.002~0.50 |
mg/L |
5%(F,S) |
| 71 |
lead |
0.01~0.50 |
mg/L |
5%(F,S) |
| 72 |
antimony |
0.50~10.0 |
mg/L |
5%(F,S) |
73
|
chroma(Low range) |
5~50 |
PCU |
3%(F,S) |
74
|
chroma(High range) |
50~500 |
PCU |
3%(F,S) |
75
|
turbidity |
0~400 |
NTU |
≤2%(F,S) |
76
|
suspended solids |
5~1000 |
mg/L |
≤2%(F,S) |
| 77 |
PH (colorimetric method) |
5.00~8.00 |
PH |
0.1±0.1 |
| 78 |
PH (electrode method) |
0.00~14.00 |
PH |
±0.1 |
| 79 |
Dissolved oxygen (colorimetric method) |
0.1~10.0 |
mg/L |
0.1±5% |
| 80 |
Dissolved oxygen (electrode method) |
0~20.0 |
mg/L |
±0.2 |
| 81 |
Conductivity (electrode method) |
0.00µs/cm-199.9ms/cm
|
ms/cm |
±1.0%(F,S) |
| 82 |
TDS(Electrode method) |
0.0mg/L~199.9g/L
|
g/L |
±0.5%(F,S) |
COD ammonia nitrogen total phosphorus total nitrogen analyzer, multi parameter water quality number detectorConfiguration List
1 host, 1 digestion instrument (including CODcr, total phosphorus, total nitrogen, etc.) CODMn、 The total chromium parameter is required for preparation. Reagent preparation is usually based on the parameter configuration, with one set each (for more than 10 parameters, only 10 parameter reagents are required). There are several colorimetric tubes with diameters of Ø 16mm and Ø 25mm, two colorimetric dishes (including turbidity, chromaticity, and suspended solids), two test tube racks, one pipette, one USB cable, one pH composite electrode, one conductivity electrode, one dissolved oxygen electrode, and one temperature electrode (corresponding electrodes can be configured according to the selected parameters). One data acquisition and installation CD, one user manual, one product certificate, and one warranty card are also required.