Welcome Customer !

Membership

Help

Shanghai Lingchu Environmental Protection Instrument Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products
Product Categories

Shanghai Lingchu Environmental Protection Instrument Co., Ltd

  • E-mail

  • Phone

  • Address

    Room 407, Taichen Business Building, 158 Bole South Road, Jiading District, Shanghai

Contact Now

Pollution Index SDI Tester

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The AQUALYSIS 100SDII pollution index SDI measuring instrument is not only suitable for online installation and use, but also for mobile use. Users can flexibly choose the installation method according to the actual situation on site. The recommended usage and installation method is online, which is a fixed online installation method that meets the standard configuration of an automatic SDI analyzer.

Product Details

Pollution Index SDI Tester


Pollution Index SDI TesterAQUALYSIS 100SDI is not only suitable for online installation and use, but also for mobile use. Users can flexibly choose the installation method according to the actual situation on site. The recommended usage and installation method is online, which is a fixed online installation method that meets the standard configuration of an automatic SDI analyzer. Widely used in water supply plants, sewage treatment plants, steel/metallurgy, petroleum/chemical, power, papermaking, textile/printing and dyeing, brewing, fine chemicals, pharmaceuticals, coal mines, food and beverage, electronics/circuits, electroplating/surface engineering, energy, seawater desalination, ships, boilers, etc.

Pollution Index SDI TesterMeasurement principle:

During installationDuring the SDI analyzer process, users can set the sampling port on the pipeline before entering the reverse osmosis system. The usual practice is to connect a three-way valve on the main pipeline, and a valve needs to be installed on the sampling pipeline to open and close the sampling. To prevent debris from entering the pipeline of the automatic SDI detector, it is recommended to install a pipeline filter. The SDI measuring instrument sampling tube is directly or indirectly connected to the pipeline filter through a conversion joint. If the sampling pipeline is too long, a bypass with an overflow valve must be installed, and a long flow of water must be maintained inside the sampling pipeline to prevent debris from settling.

Pollution Index SDI TesterConcentrate the functions of bypass, venting, and drainage in one drainage pipe, which is a 10mm transparent plastic pipe. The drainage pipe is ultimately inserted into the drainage ditch.

污染指数SDI测定仪

Pollution Index SDI TesterTechnical specifications

model

AQUALYSIS 100SDI

measurement range

0.2~ 6.67(SDI15min)

accuracy

±0.2(SDI15min)

pre-membrane pressure

0.207Mpa

display panel

LCD display, 4 operation and control touch keys

Microporous filter

φ25mm

Filter membrane specifications

φ25mm , 孔径0.45 μm±0.02μm

Water sample container

150mL

protection level

IP66, NEMA 4X

set point

Four sets of relay contacts (single channel)

Sixteen sets of relay contacts (four channels)

signal output

four groups4~20 mA isolated current output (single channel)

Sixteen groups4~20 mA isolated current output (four channels)

Operating temperature and humidity

0~55 ℃, vu; relative humidity 30~95%

power supply

120 / 240VAC 50 / 60Hz