Welcome Customer !

Membership

Help

Shanghai Lingchu Environmental Protection Instrument Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products
Product Categories

Shanghai Lingchu Environmental Protection Instrument Co., Ltd

  • E-mail

  • Phone

  • Address

    Room 407, Taichen Business Building, 158 Bole South Road, Jiading District, Shanghai

Contact Now

Cationic polymer analyzer for power plants

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The PROCON POLY20/30 cationic polymer analyzer for power plants uses the cationic polymer method to quantitatively determine the turbidity reaction between two reagents. The turbidity level is proportional to the concentration of the product and is determined by photometry. It can monitor the concentration of polymers (such as polyacrylate modulators) in water and provide feedback signals to achieve automatic control of the dosing system.

Product Details

Cationic polymer analyzer for power plants



Cationic polymer analyzer for power plantsceremonyPROCON POLY20/30By using cationic polymer method, turbidity reaction occurs between two quantitatively given reagents, and the turbidity level is proportional to the concentration of the product, which is determined by photometry. It can monitor the concentration of polymers (such as polyacrylate modulators) in water and provide feedback signals to achieve automatic control of the dosing system.

Product Features:

·Measurement parameters: polyacrylate, polymer

·Measurement range: Customized by customers, 0.1-150 mgl polyacrylate

·Can monitor the concentration of polymers (such as polyacrylate modulators) in water and provide feedback signals to achieve automatic control of the dosing system

·The cationic polymer method involves a turbidity reaction between two quantitatively given reagents, where the turbidity level is proportional to the concentration of the product, and is determined by photometry

·When the measurement result reaches a certain value, the feed metering pump will be activated through the limit contact or optional 0/4-20mA analog output device to ensure that there is always sufficient chemical regulator in the water, preventing chemical regulator from being supplied

·At the same time as excessive material consumption, it greatly reduces monitoring costs

·Equipped with manual calibration function


Technical parameters:


PROCON POLY20 PROCON POLY30

measurement range

0.1-20.0ppm

10-150ppm

resolution

0.1ppm

1ppm

Zero stability

auto-adjust

analysis

cycle

interval


4-7 minutes with rinsing included

1-99minuteOr external start stop

current output

0/4-20mA, Load 500 Ω

display

240 × 128, touch screen

Operating Temperature

5-45 degrees Celsius

electrical connection

1.5mm2 circular plug connection


relay

1 x Alarm, Passive 230v/50Hz, 3A

1 x limit, passive 230v/50Hz, 3A

1 x Analysis Status, Passive 230v/50Hz, 3A

remote control

Passive, 18V DC, ca.4 mA

power supply voltage

110-230V (50/60Hz)

energy consumption

Approximately 16VA

size

640×315×190mm(H×W×D)

protection level

IP65