Pollen/Biological Aerosol Automatic Monitor

NegotiableUpdate on 12/21
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The SwisensPoleno Jupiter pollen/bioaerosol automatic monitoring instrument can generate digital fingerprints containing morphological data and chemical composition for each particle entering the analyzer through technologies such as digital holographic imaging, fluorescence spectroscopy measurement, light scattering, and polarization measurement. Further processing and classification can be achieved through machine learning algorithms, enabling autonomous identification and automatic measurement of pollen, spore, bioaerosols, and solid particle concentrations in the air.
Product Details

花粉/生物气溶胶自动监测仪


System Introduction

Pollen and various biogenic particles in the air belong to the scope of bioaerosols, playing an irreplaceable role in the interactions between the Earth system, especially in the atmosphere, biosphere, climate, and public health. It is an important research topic in related fields such as public health, pollen load, air pollution, climate change, and their interdisciplinary fields.

SwisensPoleno JupiterPollen/Biological Aerosol Automatic MonitorThrough technologies such as digital holographic imaging, fluorescence spectroscopy, light scattering, and polarization measurement, a digital fingerprint containing morphological data and chemical composition can be generated for each particle entering the analyzer. Further processing and classification can be achieved through machine learning algorithms, enabling autonomous identification and automatic measurement of the concentrations of pollen, spores, bioaerosols, and solid particles in the air.


Application field

climate change

·Research on Atmospheric Chemical Composition and Its Variation Process

·Research on the Physical Composition of Clouds and Hydrological Cycle Processes

·Biodiversity research

Soil utilization changes

·Research on agricultural production related to bioaerosols

public health

·Research on Human Pathogens

·Allergen particle research


Features and advantages

·Simultaneously measure particle classification and concentration

·Each particle generates a digital fingerprint that includes morphological and chemical composition data

·Output multiple system parameters to determine the operating status of the system, such as particle velocity, particle concentration, airflow, temperature, response time, storage space usage, etc

·Particle classification can be completed within seconds, achieving minute level measurement time resolution

·Machine learning algorithms can be used to build and expand one's own pollen library

·The original data can be retained and unknown particles can be recalculated

·Data management is simple and convenient, presented intuitively, supports automatic transmission of data in multiple download formats, and supports remote operation

·Compared to others, it is smaller in size and can be installed manually

·No consumables, cost saving, low maintenance, with self-cleaning function

·Simple structure, sturdy and durable, ensuring long-term stable operation


Schematic diagram

花粉/生物气溶胶自动监测仪


A new method for real-time monitoring of bioaerosols

·Specially designed for the exploration and pioneering automatic monitoring and measurement of the microscopic world of biological aerosols. It can be used for scientific measurements in laboratories and for long-term automatic monitoring outdoors.

Jupiter's measurement process is based on the following technical elements:

·Digital holographic image measurement

·Fluorescence spectroscopy measurement

·Light scattering and polarization measurement

Measurement components:

1. Sigma-2 injection tube

2. Particle concentrator

3. Two holographic cameras with a 90 ° angle to each other

4. Three fluorescent light sources and five independent spectral receivers

5. Horizontal and vertical polarized scattered light receivers

6. Insertable sample collector (optional)

7. Air outlet


Technical Specifications

花粉/生物气溶胶自动监测仪



1Compared to other biological aerosol particles, pollen concentration in the atmosphere is usually lower (about 10-10000 particles/m)3)However, the threshold for allergic reactions is usually lower, ranging from a few pills to tens of pills per meter depending on the classification group3Can cause sensitization; SwisensPoleno uses a particle concentrator based on the principle of virtual impactor to achieve an effective flow rate of 40L/min, ensuring minute level time resolution.



花粉/生物气溶胶自动监测仪


Pollen/Biological Aerosol Automatic Monitor