Compliant with IP67 waterproof standard, adopting innovative optical system design, withtallThe precision, repeatability, and time required for measurement are carefully designed with CAL Check ™ The function allows for performance validation and calibration of instruments using NIST traceable standards, multiple measurement methods, built-in reaction timers to ensure consistency between sample measurements and user results, automatic recording of 50 measurement readings, Good Laboratory Practice (GLP) display of the last user calibration date and time, battery status indicator light, and automatic shutdown settings
Compared with traditional tungsten lamps and other light sources, LED light sources have more advantagesgoodThe performance and higher luminous efficiency of LED can provide the best and stable light source with less energy. LED can ignore the heat generated by itself, as higher heat can affect the stability of electronic products.
8 nm narrowband interference filter, accurate to ± 1 nm, with a 25% increase in absorbance. The improved optical filter ensures higher wavelength accuracy and allows for brighter, stronger signals to be received, higher measurement stability, and less wavelength error, ensuring measurement accuracy and precision.
The internal reference system can compensate for any drift caused by battery voltage fluctuations or environmental temperature changes. By automatically adjusting the voltage of the LED, it achieves consistent and stable light source output, enabling fast and stable readings between blank (zero) measurements and sample measurements.
High quality concave focusing lenses can collect all the light transmitted through the glass cuvette, reducing errors caused by defects and scratches in the glass cuvette, and minimizing errors and reading deviations caused by defects in the glass cuvette.
Carefully designed CAL Check ™ Function, allowing the use of NIST traceable standards for instrument performance validation and calibration; CAL Check ™ NIST curve calibration group is used to simulate specific absorbance values for each wavelength to verify the accuracy of subsequent readings. CAL Check ™ The CAL check screen guides the user through the verification process and user calibration step by step.
| Technical Specifications | HI97727 PCU (Platinum Cobalt Unit) |
|---|---|
| measurement range | 0 to 500 PCU (Platinum Cobalt Units) |
| resolution | 1 PCU (Platinum Cobalt Unit) |
| precision | 25ºC/77ºF |
| reading | ±5% ± 10 PCU |
| standard method | Platinum cobalt colorimetric method |
| Light source mode | silicon photocell, LED @ 420 nm |
| Filter bandwidth | 8 nm ±1.0 nm |
| data management | 50 readings stored |
| Power mode | 3 × 1.5AAA high-performance battery, automatically shuts down after 15 minutes of inactivity in measurement mode |
| Usage environment | 0 to 50 ° C (32 to 122 ° F), RH max 100%, compliant with IP67 waterproof standard |
| Dimensions & Weight | Host size: 142.5 x 102.5 x 50.5 mm (5.6 x 4.0 x 2.0 '), host weight: 380 g (13.4 oz.) |
| Exclusive attachments | HI731397 glass colorimetric dish (HI731331+HI731336), specification: outer diameter 24.6mm (inner diameter 22mm), 4 sets/group |
| Standard Curve Verification Group | HI97727-11 Platinum Cobalt Chromaticity NIST Measurement Curve Calibration Group, Standard Value @ 25 º C: 0 and 250 ± 5 PCU |
| HI97727 | Host, HI731397 customized specialized glass colorimetric dish (2 pieces), HI731318 specialized glass colorimetric dish cleaning cloth (2 pieces), Chinese and English user manual, HI721097 customized specialized instrument carrying case [Warm reminder: To verify instrument performance, please order HI97727-11 Platinum Cobalt Colorimetric NIST Measurement Curve Calibration Group] |
|---|---|
| HI97727C | Host, HI97727-11 Platinum Cobalt Colorimetric NIST Measurement Curve Calibration Group, HI731397 Customized Special Glass Colorimetric Plates (2 pieces), HI731318 Special Glass Colorimetric Plate Cleaning Cloth (2 pieces), Chinese and English User Manual, HI721097 Customized Special Instrument Carrying Case |