- Phone
-
Address
A6-2 Jinke Yida Science and Technology City, No. 77, South Section of Dongliu Road, Changsha Economic and Technological Development Zone, Hunan Province
Bichen Instrument
A6-2 Jinke Yida Science and Technology City, No. 77, South Section of Dongliu Road, Changsha Economic and Technological Development Zone, Hunan Province
MultiTalent PX2 The biodegradation analyzer can be widely used in various testing standards and is professionally applied to the aerobic environment degradation of plastics by microorganisms. It meets relevant domestic and foreign standards in various aspects such as experimental design, sample and inoculum processing, material sampling and storage, measurement principles, measurement indicators, experimental measurement devices, data collection, and data analysis and calculation. Directly test the oxygen consumption or determine the amount of carbon dioxide released, and calculate the biodegradation rate of the tested material by comparing it with the theoretical value.
Product Application
Aerobic biodegradationBiochemical Oxygen Demand
Biodegradability of plastics under composting conditionsOther related tests
Biodegradability of plastics under soil environmental conditionsHigh solid dry anaerobic fermentation
Oxygen absorption rate of activated sludge(OUR)Anaerobic ammonia oxidizing bacteria activity (SAA)
Aerobic biodegradability under freshwater environmental conditionsbiomass energy
Biodegradability under marine environmental conditionsNutritional research on ruminants
Product Features
Standardized conversion, the measured data is corrected to the volume under standard conditions(0℃,1atm)
Double alkaline adsorptionCO2 Device, * adsorptionCO2 Create negative pressure to ensure the accuracy of oxygen consumption data
The instrument has a high degree of automation, and the integration of sampling, recording, analysis, and report output is completed
Intelligent mixing system, supporting low-frequency precise mixing
7Inch touch screen, integrated data storage

Overall control throughout the experiment
This software supports users to monitor the status of each group of experiments in real-time during the experimental process. Users can also start, pause, and stop ongoing experiments and collect experimental data at any time with a simple operation.
Users can observe the cumulative aerobic curve and dynamic degradation curve trends of each reactor through the operation interface, and the data displayed on the graph has been calibrated to standard conditions (1 atmosphere, 0 ℃, 0 moisture content). With the help of the built-in Linux server application in the system software, users can monitor the progress of experiments and the running dynamics of each reaction bottle in real time from anywhere.
technical parameters
Biological fermentation unit
Maximum number of reactors per batch experiment: 15
Reactor Material: Glass Reactor Volume: 500 mL
Water bath specification: 53 × 33.5 × 24.2 cm (18 L)
Temperature control: 30-95 ℃ (accuracy ± 0.2 ℃)
Material mixing: mechanical stirring, controllable stirring rate and cycle, maximum speed up to 200rpm
Biological fermentation unit(Suitable for testing options in freshwater and marine environments)
Maximum number of reactors per batch experiment: 6-15
Reactor material and volume: glass, 250-1000 mL
Voltage: 110-240 ± 10% V
Magnetic stirring specification: 250 × 350 × 25 mm
Ultra thin 304 stainless steel shell design, sturdy and durable, easy to clean
Material mixing: maximum speed 2000rpm
Gas flow rate andDAQunit
Principle: Gas liquid displacement and buoyancy control method
15 sets of trace gas flow collection can run simultaneously
Built in temperature and pressure sensors
Embedded chip completes fully automatic data acquisition and analysis
Measurement resolution: 1.8 mL (standard configuration)
Detection capacity: single standard configuration channel (2mL resolution)
Accumulated gas production measurement upper limit reaches 35L
Specification size: 51 × 44 × 18 cm
Material: Engineering plastics
Repeatability accuracy: ± 1%
CO2 Adsorption unit
Number of CO2 adsorption bottles: capable of connecting 15 reactors simultaneously
Embedded adsorption filtration alkali block design: 15 reactor interiors
Absorbent solution: 80mL, 3M NaOH solution and pH indicator (not included in the supply scope)
Carbon dioxide absorption efficiency:>98%