Welcome Customer !

Membership

Help

Bichen Instrument
Custom manufacturer

Main Products:

instrumentb2b>Products

Bichen Instrument

  • E-mail

  • Phone

  • Address

    A6-2 Jinke Yida Science and Technology City, No. 77, South Section of Dongliu Road, Changsha Economic and Technological Development Zone, Hunan Province

Contact Now

Plastic Biodegradation Analyzer

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The MultiTalent PX2 Biodegradation Analyzer can be widely used in various testing standards and is specialized in microbial aerobic environment degradation of plastics. It meets relevant domestic and international standards in various aspects such as experimental design, sample and inoculum processing, material sampling and storage, measurement principles, measurement indicators, experimental measurement devices, data collection, and data analysis and calculation. Directly test the oxygen consumption or determine the amount of carbon dioxide released, and calculate the biodegradation rate of the tested material by comparing it with the theoretical value.

Product Details

MultiTalent PX2 The biodegradation analyzer can be widely used in various testing standards and is professionally applied to the aerobic environment degradation of plastics by microorganisms. It meets relevant domestic and foreign standards in various aspects such as experimental design, sample and inoculum processing, material sampling and storage, measurement principles, measurement indicators, experimental measurement devices, data collection, and data analysis and calculation. Directly test the oxygen consumption or determine the amount of carbon dioxide released, and calculate the biodegradation rate of the tested material by comparing it with the theoretical value.


Product Application

Aerobic biodegradationBiochemical Oxygen Demand

Biodegradability of plastics under composting conditionsOther related tests

Biodegradability of plastics under soil environmental conditionsHigh solid dry anaerobic fermentation

Oxygen absorption rate of activated sludge(OUR)Anaerobic ammonia oxidizing bacteria activity (SAA)

Aerobic biodegradability under freshwater environmental conditionsbiomass energy

Biodegradability under marine environmental conditionsNutritional research on ruminants


Product Features

Standardized conversion, the measured data is corrected to the volume under standard conditions(0℃1atm

Double alkaline adsorptionCO2 Device, * adsorptionCO2 Create negative pressure to ensure the accuracy of oxygen consumption data

The instrument has a high degree of automation, and the integration of sampling, recording, analysis, and report output is completed

Intelligent mixing system, supporting low-frequency precise mixing

7Inch touch screen, integrated data storage


image.png


Overall control throughout the experiment

This software supports users to monitor the status of each group of experiments in real-time during the experimental process. Users can also start, pause, and stop ongoing experiments and collect experimental data at any time with a simple operation.

Users can observe the cumulative aerobic curve and dynamic degradation curve trends of each reactor through the operation interface, and the data displayed on the graph has been calibrated to standard conditions (1 atmosphere, 0 ℃, 0 moisture content). With the help of the built-in Linux server application in the system software, users can monitor the progress of experiments and the running dynamics of each reaction bottle in real time from anywhere.


technical parameters

Biological fermentation unit1637740086(1).jpg

Maximum number of reactors per batch experiment: 15

Reactor Material: Glass Reactor Volume: 500 mL

Water bath specification: 53 × 33.5 × 24.2 cm (18 L)

Temperature control: 30-95 ℃ (accuracy ± 0.2 ℃)

Material mixing: mechanical stirring, controllable stirring rate and cycle, maximum speed up to 200rpm


Biological fermentation unit(Suitable for testing options in freshwater and marine environments)1637740152(1).jpg

Maximum number of reactors per batch experiment: 6-15

Reactor material and volume: glass, 250-1000 mL

Voltage: 110-240 ± 10% V

Magnetic stirring specification: 250 × 350 × 25 mm

Ultra thin 304 stainless steel shell design, sturdy and durable, easy to clean

Material mixing: maximum speed 2000rpm


Gas flow rate andDAQunit1637740277(1).jpg

Principle: Gas liquid displacement and buoyancy control method

15 sets of trace gas flow collection can run simultaneously

Built in temperature and pressure sensors

Embedded chip completes fully automatic data acquisition and analysis

Measurement resolution: 1.8 mL (standard configuration)

Detection capacity: single standard configuration channel (2mL resolution)

Accumulated gas production measurement upper limit reaches 35L

Specification size: 51 × 44 × 18 cm

Material: Engineering plastics

Repeatability accuracy: ± 1%


CO2 Adsorption unit

Number of CO2 adsorption bottles: capable of connecting 15 reactors simultaneously

Embedded adsorption filtration alkali block design: 15 reactor interiors

Absorbent solution: 80mL, 3M NaOH solution and pH indicator (not included in the supply scope)

Carbon dioxide absorption efficiency:>98%