Welcome Customer !

Membership

Help

Tianjin Parallel Saisi Technology Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Tianjin Parallel Saisi Technology Co., Ltd

  • E-mail

  • Phone

  • Address

    Fuyuan Road North Test Entrepreneurship Headquarters Base, Wuqing Development Zone, Tianjin City

Contact Now

PlasmaCAL internal standard calibration solution Mix 1-SCP-IS7

NegotiableUpdate on 05/19
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

PlasmaCAL internal standard calibration solution Mix 1-SCP-IS7 $r $n professional traceability: sourced from SCP Science in Canada, it meets the strict quality control requirements of instrument analysis such as ICP-MS/ICP-OES, and is a reliable internal standard choice for laboratory element analysis. $r $n Accurate Matching: Designed specifically for plasma spectroscopy/mass spectrometry, it can effectively correct matrix effects, instrument drift, and improve the accuracy and repeatability of detection results. Stable and reliable: 5% nitric acid matrix effectively prevents element adsorption and precipitation, ensuring long-term stability and excellent consistency between batches.

Product Details

PlasmaCAL internal standard calibration solution Mix 1-SCP-IS7 The detailed information is as follows:



PlasmaCALInternal standard calibration solution (7 elements) 140-111-081

Signal drift correction in ICP-MS testing; The element mass is uniformly distributed in low, medium, and high levels

Equivalent to SPEX CL-ISM1, Agilent 5183-4681

Bi,Ge, In,6Li, Sc,Tb, Y

Concentration: 10ppm

Medium: 5% HNO3

Volume (ml): 125ml




ICP-MS internal standard calibration solution precious metal mixed standard sample (10 elements)

equivalent PE N930-0235 Agilent 8500-6948

Purpose: General research and quantitative analysis; Mainly used for ICP-MS

Part number: 700-101-105

元素: Au , Hf Ir , Pd , Pt , Rh , Ru, Sb, Sn, Te

Concentration: 10ppm

Medium: 10% HCl

volume (ml):2X25ml



ICP-MS internal standard calibration solution with 8 elements

Equivalent to Agilent 5188-6525

Part number: 140-111-201

元素: 6Li, Sc, Ge, Rh, In, Tb, Lu, Bi.

Concentration: 100ppm

Medium: 5% HNO3

volume (ml):125ml



Multi element calibration standard-2A (27 elements)

Equivalent to Agilent 8500-6940

Part number: 140-109-111

元素: Ag,Al,As,Ba,Be,Ca,Cd,Co,Cr,Cs,Cu,Fe,Ga,K,Li,Mg,Mn,Na,Ni,Pb,Rb,Se,Sr,Tl,U,V,Zn

Concentration: 10ppm

Medium: 5% HNO3

volume (ml):125ml

reagent bottle 2 (Part number: 140-110-111)

contain10 mg/L Hg, with a substrate of 5% HNO3 solution


ICP-MS tuning solution (6 elements)

Equivalent to Agilent 5190-0465

Part number: AQ0-122-601

Element:Li、Mg、Y、Ce、Tl、Co

Concentration: 10ppm

Medium: 5% HNO3 Agilent matrix is a 2% HNO3 solution

volume (ml):125ml



ICP-MS tuning solution (6 elements)

Equivalent to Agilent 5185-5959

Part number: AQ0-081-035

Element:Li、Mg、Y、Ce、Tl、Co

Concentration: 1 ppb

Medium: 5% HNO3 Agilent matrix is a 2% HNO3 solution

volume (ml): 500ml Agilent is2 x 500 mL bottles



ICP-MS reserve tuning solution (5 elements)

Equivalent to Agilent 5188-6564

Part number: AQ0-103-851

Element:Li、Y、Ce、Tl、Co

Concentration: 10ppm

Medium: 2% HNO3

volume (ml):125ml

PlasmaCAL internal standard calibration solution Mix 1-SCP-IS7 For more information, please contact us!


Parallel Saisi provides you with a range of ICP-OES/ICP-MS standard solutions and quality control standard solutions. The EPA Method 200.7 covers the routine monitoring requirements for metal and non-metal elements in water and wastewater using ICP-OES for vertical or horizontal observation. The EPA Method 200.8 includes the use of ICP-MS to analyze elements specified in groundwater, surface water, drinking water, and wastewater. The EPA Method 6010c, combined with the Toxicity Characteristic Leaching Procedure (TCLP) or Extraction Procedure (EP) for solid waste, specifies the use of ICP-OES to determine 31 elements in groundwater, industrial and organic waste, soil, silt, and sediment.