- Phone
-
Address
Fuyuan Road North Test Entrepreneurship Headquarters Base, Wuqing Development Zone, Tianjin City
Tianjin Parallel Saisi Technology Co., Ltd
Fuyuan Road North Test Entrepreneurship Headquarters Base, Wuqing Development Zone, Tianjin City
PlasmaCAL internal standard calibration solution Mix 1-SCP-IS7 The detailed information is as follows:
PlasmaCALInternal standard calibration solution (7 elements) 140-111-081
Signal drift correction in ICP-MS testing; The element mass is uniformly distributed in low, medium, and high levels
Equivalent to SPEX CL-ISM1, Agilent 5183-4681
Bi,Ge, In,6Li, Sc,Tb, Y
Concentration: 10ppm
Medium: 5% HNO3
Volume (ml): 125ml
ICP-MS internal standard calibration solution precious metal mixed standard sample (10 elements)
equivalent PE N930-0235 Agilent 8500-6948
Purpose: General research and quantitative analysis; Mainly used for ICP-MS
Part number: 700-101-105
元素: Au , Hf Ir , Pd , Pt , Rh , Ru, Sb, Sn, Te
Concentration: 10ppm
Medium: 10% HCl
volume (ml):2X25ml
ICP-MS internal standard calibration solution with 8 elements
Equivalent to Agilent 5188-6525
Part number: 140-111-201
元素: 6Li, Sc, Ge, Rh, In, Tb, Lu, Bi.
Concentration: 100ppm
Medium: 5% HNO3
volume (ml):125ml
Multi element calibration standard-2A (27 elements)
Equivalent to Agilent 8500-6940
Part number: 140-109-111
元素: Ag,Al,As,Ba,Be,Ca,Cd,Co,Cr,Cs,Cu,Fe,Ga,K,Li,Mg,Mn,Na,Ni,Pb,Rb,Se,Sr,Tl,U,V,Zn
Concentration: 10ppm
Medium: 5% HNO3
volume (ml):125ml
reagent bottle 2 (Part number: 140-110-111)
contain10 mg/L Hg, with a substrate of 5% HNO3 solution
ICP-MS tuning solution (6 elements)
Equivalent to Agilent 5190-0465
Part number: AQ0-122-601
Element:Li、Mg、Y、Ce、Tl、Co
Concentration: 10ppm
Medium: 5% HNO3 Agilent matrix is a 2% HNO3 solution
volume (ml):125ml
ICP-MS tuning solution (6 elements)
Equivalent to Agilent 5185-5959
Part number: AQ0-081-035
Element:Li、Mg、Y、Ce、Tl、Co
Concentration: 1 ppb
Medium: 5% HNO3 Agilent matrix is a 2% HNO3 solution
volume (ml): 500ml Agilent is2 x 500 mL bottles
ICP-MS reserve tuning solution (5 elements)
Equivalent to Agilent 5188-6564
Part number: AQ0-103-851
Element:Li、Y、Ce、Tl、Co
Concentration: 10ppm
Medium: 2% HNO3
volume (ml):125ml
PlasmaCAL internal standard calibration solution Mix 1-SCP-IS7 For more information, please contact us!
Parallel Saisi provides you with a range of ICP-OES/ICP-MS standard solutions and quality control standard solutions. The EPA Method 200.7 covers the routine monitoring requirements for metal and non-metal elements in water and wastewater using ICP-OES for vertical or horizontal observation. The EPA Method 200.8 includes the use of ICP-MS to analyze elements specified in groundwater, surface water, drinking water, and wastewater. The EPA Method 6010c, combined with the Toxicity Characteristic Leaching Procedure (TCLP) or Extraction Procedure (EP) for solid waste, specifies the use of ICP-OES to determine 31 elements in groundwater, industrial and organic waste, soil, silt, and sediment.