E-mail
13611105654@163.com
-
Phone
13611105654
- Address
Beijing Tongda Zhichuang Technology Co., Ltd
13611105654@163.com
13611105654
OneTypes and scope of application of products
1. TDZC-LUGB series full tube piezoelectric vortex flowmeter
2. TDZC-LUGB series plug-in piezoelectric vortex flowmeter
3. TDZC-LUGE series full tube capacitive vortex flowmeter
4. TDZC-LUGE series plug-in capacitive vortex flowmeter
5. TDZC-LUGB/E series battery powered vortex flowmeter
6. Submersible/Split Vortex Flow Meter (Protocol Order)
7. Multi functional curve recording integrator with P/T compensation function and Chinese LCD display
8. Intelligent traffic integrator with digital display
The TDZC-LUGB/E vortex flowmeter is widely used in industries such as petroleum, chemical, metallurgical, thermal, textile, and papermaking for measuring and controlling superheated steam, saturated steam, compressed air, and general gases (oxygen, nitrogen, hydrogen, natural gas, coal gas, etc.), water, and liquids (such as water, gasoline, alcohol, benzene, etc.)
IIworking principle
If a non streamlined vortex generator (flow resistant fluid) is set up in the fluid, two columns of regular vortices are alternately generated from both sides of the vortex generator. This type of vortex is called a Karman vortex street, as shown in Figure (1).The vortices are arranged asymmetrically downstream of the vortex generator. Let the frequency of vortex occurrence bef, The average velocity of the incoming flow of the measured medium is V, and the vortex generator is upstreamThe width of the face isd, The diameter of the body is D. According to the principle of Karman vortex street, there is the following relationship:
Formula (1) for f=StV/d
Where:
F - frequency of Karman vortex generated on one side of the body
St Strouhal number (dimensionless number)
V - Average flow velocity of fluid
D - width of vortex generator
From this, it can be seen that the instantaneous flow rate can be calculated by measuring the separation frequency of the Karman vortex street. Among them, Strouhal number (St) is an dimensionless unknown variable,
Figure (2) shows the relationship between Strouhal number (St) and Reynolds number (Re).
In the curve tableSt=The straight part of 0.17, the frequency of vortex release is proportional to the flow velocity, which is the measurement range of the vortex flow sensor. As long as the frequency f is detectedThe flow velocity of the fluid inside the pipe can be obtained by measuring the flow velocityCalculate the volumetric flow rate for V. The ratio of the measured number of pulses to the volume is called the instrument constant (K), as shown in equation (2)
K=N/Q (1/m ³) formula (2)
In the formula: K=instrument constant (1/m ³).
N=number of pulses
Q=Volume flow rate (m ³)
IIIMain technical indicatorsTable (1)
|
Nominal diameter (mm) |
25, 40, 50, 65, 80, 100, 125, 250, 200, 250, 300 (300-1000 plug-in type) |
|
Nominal pressure (MPa) |
DN25-DN200 4.0 (>4.0 protocol supply), DN250-DN300 1.6 (>1.6 protocol supply) |
|
Medium temperature (℃) |
Piezoelectric type:-40~260,-40~320Capacitive type:-40~300,-40~400,-40~450(Agreement ordering) |
|
body material |
1Cr18Ni9Ti, (Other material agreement supply) |
|
Allow vibration acceleration |
Piezoelectric type: 0.2g Capacitive type: 1.0~2.0g |
|
**Degree |
± 1% R, ± 1.5% R, ± 1FS; Insertion type: ± 2.5% R, ± 2.5% FS |
|
Range degree |
1:6~1:30 |
|
power supply voltage |
Sensor:+12V DC,+24V DC; Transmitter:+12VDC ,+24V DCBattery powered type:3.6V battery |
|
output signal |
Square wave pulse (excluding battery power supply)type)High level ≥ 5V, low level ≤ 1V; current: 4-20mA |
|
Pressure loss coefficient |
Complies with JB/T9249 standard Cd ≤ 2.4 |
|
Explosion-proof marking |
Intrinsic safety type:ExdⅡiaCT2-T5 Explosion prooftype:ExdⅡCT2-T5 |
|
Protection level |
普通型IP65Diving typeIP68 |
|
environmental conditions |
Temperature -20 ℃~55 ℃, relative humidity 5%~90%, atmospheric pressure 86~106kPa |
|
Applicable Medium |
Gas, liquid, steam |
|
transmission distance |
Three wire pulse output type:≤300m, two-wire systemStandard current output type(4~20mA): Load electricityblock≤750Ω |