Photovoltaic cell light decay test chamber

NegotiableUpdate on 07/07
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Photovoltaic cell light attenuation test box JW-2619GS-512 $r $n1. Inner box dimensions: width: 3300mm, height: 2000mm, depth: 2800mm $r $n2. External dimensions: width: 4300mm, height: 2550mm, depth: 3350mm (subject to actual drawing) $r $n3. Effective irradiation area width: 3000mm; depth: 2600mm; at the same time (meeting 2 pieces of 21072 type half cell modules), 144 pieces of 210mm cells can be placed inside the light attenuation box

Product Details

Photovoltaic cell light decay test chamberJW-2619GS-512

Photovoltaic cell light decay test chamberJW-2619GS-512

Photovoltaic cell light decay test chamberJW-2619GS-512

OneBasic technical indicators:

1. Test battery specifications: 210*210mm, Compatible with 180 * 180mm-230 * 230mm, silicon wafer thickness 150-220um

2. Inner box dimensions Width:3300mm high: 2000mm deep: 2800mm

3. Overall dimensions Width:4300mm height: 2550mm depth: 3350mm (subject to actual drawing)

4. Wide effective irradiation area3000mm; Depth 2600mm; Simultaneously(satisfy 2 pieces of 210 72 type half piece components))Light attenuation boxAnd it can be placed 144 210mm battery cells

5. Temperature range:50 ℃ to 120 ℃;

6. Temperature fluctuation:≤±0.5℃

7. Heating rate:≥1℃/min

8. 降温速率:≥0.5℃/min

9. Temperature deviation;±5℃

10. Temperature measurement accuracy:±0.1℃;

11. Temperature control: forced air circulation;

12. Ambient temperature 5-35 ℃, relative humidity ≤ 85% RH

13. Radiation intensity: average radiation intensity1000W/m ² (continuously adjustable within 50% -100% light intensity); Light intensity: 700-1300W/M2

14. Spectral matching degree of irradiation:400nm至1100 nm,Class B 级(0.6-1.4);

15. Radiation non-uniformity:Class B, ≤ 5%, measuring tools: silicon solar cell, I-V converter, fast acquisition card;

16. Radiation instability:Class A , ≤ 2%, measuring tools: silicon solar cell, I-V converter, fast acquisition card;

17. Light Source Warranty: Warranty≥ 2000 hours, with a light intensity attenuation of less than 10% within 2000 hours; Warranty life 1000H

18. Light source type: Metal halogen lamp (number of light sources:6 (one lamp with one power supply);

19. Power:4000W

20. Radiation detector: R&D grade solar irradiance radiometerISO9060 standard, ISO Level 2 meter measurement accuracy better than ± 5%, resolution better than 1W/m ²;

21. A matching sample rack is required: bearing capacity3000 x 2600 x 50mm(W x D x H); There is tempered glass on the bracket for easy placement of battery cells of the same area;

22. Uptime ≥ 99% calculation method: downtime/24 * 100 ≥ 99%;

23. MTTR<1 hour, MTBF ≥ 450 hours;

24. Light source wavelength:280nm--3000nm

25. Measurement spectrum:300nm--1100nm

26. Third party metrology calibration certificate is required (specific legal metrology equipment qualifications: China Institute of Metrology, Fujian Institute of Metrology, Shanghai Institute of Metrology, Guangdong) Provided by either the Metrology Institute or Suzhou Metrology Institute;

Remark1:IEC60904-9 Performance Requirements for Solar Simulators

2:IEC61215:2016 Ground use crystalline silicon photovoltaic modules - Design identification and determination

2、 Structural design:

2.1. Inner box material: The inner box is made of SUS # 304 (thickness 1.0mm) stainless steel plate, with overall structural design and reinforcement.

2.2. Outer box material: Cold rolled steel plate+fine powder baking paint, with additional overall structural reinforcement.

2.3. Insulation material: Imported high-strength PU foam insulation material with a thickness of 100mm.

2.4. Sweat prevention mechanism: The heat energy from the K-type tube of the system and the thin film electric heating wire are used as sweat prevention treatment.

2.5. Box door: Adopting double insulation and airtight compression to effectively isolate external temperature leakage

2.6. Observation Window: Three layer vacuum UV resistant glass insulated window with additional lighting device

2.7. Sealing: The door adopts imported double-layer high and low temperature resistant sealing strips, and anti sweat pipes and boxes are made of high and low temperature silicon during low temperatures

Adhesive Seal

2.8. Test hole: can be used for external testing power lines and signals (50mm)

2.8. Module temperature detection: Built in temperature sensor signal feedback, adhered to the back of the module with high-temperature and UV resistant tape

2.9. Temperature detection: at least one environmental temperature probe for the box; 1 touchable temperature probe (used to monitor the temperature of the test sample, and can also be used for overall temperature control through this temperature probe); All probes have a service life of ≥ 3 years

2.10 Structural schematic diagram:

3、 Sub item of lighting system:

3.1 Light source system (German BFEPS)Or customized brand for Juwei

Selection of Lamp: Made in GermanyBF original metal halide lamp4000W, Ensure the uniformity of radiation. adopt6The group lamp tube contains a reflector cover, and the light energy output of the lamp tube will gradually decay over time. In order to reduce the impact of light energy decay on the test and the uniformity of irradiationWith a requirement of 5%, this test chamber is designed with a lamp current control system to obtain a constant output of light energy.

Lamp power adjustment range50% -100% configuration of irradiation meter and lamp current control system, which can adjust the current of the attenuated lamp by increasing it.

Lamp quality assurance2000H effective irradiation, effective service life>3000H

3.2 Electrical Control:

3.2.1 Select imported microcomputer PID temperature controller for temperature control, and use imported electronic components for the rest.

Uniformity of irradiance:5% (at the surface of the sample). Temperature monitoring: Standard PT-100 Ω thin film temperature sensors are used to accurately control the surface temperature and back temperature of the sample during the testing process.

3.2.2 The test chamber is equipped with a time controller with a range of 0~9999H, which has the functions of accumulating time and power outage memory.

3.2.3 Safety protection devices:

If the lamp is on, once the door of the box is opened, the machine will automatically cut off the power supply to the lamp. And it automatically enters a balanced state for cooling to prevent harm to the human body. The safety door lock complies withIEC047-5-1 Safety Protection Requirements.

Over temperature protection inside the box: When the temperature inside the box exceedsAt 110 º C, the machine will automatically cut off the power supply to the lamp and heater, and enter a balanced cooling state.

3.2.4 Radiometer: Select a digital irradiance meter imported from Japan with replaceable sensors and equipped with a full wavelength sensor. The original factory has calibrated it, and it is recommended to calibrate it once a year.