- Phone
-
Address
Building 3, Pumanshan, No. 71 Songzhuang Road, Fengtai District, Beijing, 2003
Beijing Sichuang Hengyuan Technology Development Co., Ltd
Building 3, Pumanshan, No. 71 Songzhuang Road, Fengtai District, Beijing, 2003
Peracetic acid concentration analyzerIt is an analytical instrument used to measure the concentration of peracetic acid in water. Peroxyacetic acid is a common chemical disinfectant widely used in water treatment, medical and other fields. The peracetic acid concentration analyzer can help users monitor the concentration of peracetic acid in water in real time, ensuring that the water treatment effect meets expectations and avoiding the problem of high or low peracetic acid concentration.
The BT6308 Pera series peracetic acid concentration analyzer from Bebur company adopts a membrane sensor, which does not require the use of reagents and buffering agents. The measurement is stable and the performance is reliable, which can reduce the maintenance and usage costs of users.
The BT6308 Pera series peracetic acid concentration analyzer from Bebur is suitable for online monitoring of peracetic acid concentration in disinfection and sterilization processes for drinking water, wastewater, industrial process water, and purified water, such as:
▪ Bottle washing machine dosing control
▪ CIP factory application
▪ Food cleaning water bleaching system
▪ Pharmaceutical factories or pharmaceutical intermediates field

▪ Adopting the diaphragm Amperometry principle sensor
▪ Stable performance and accurate measurement
▪ No need for reagents and buffer solutions
▪ Not affected by water cleaning agents
▪ No need for zero calibration
▪ Long service life
▪ Suitable for drinking water, process water, and saltwater
The sensor of the BT6308 Pera series peracetic acid concentration analyzer is a membrane type dual electrode system, which can automatically adjust the potential to eliminate zero drift. This design can eliminate the need for additional reagents or buffer solutions in water quality testing, reducing the cost for users. When calibrating, only range calibration is needed (zero calibration is not required). The BT6308 Pera series peracetic acid concentration analyzer can perform automatic dosing process control. It can control the dosage of CH3CO3H (peracetic acid) by automatically adjusting the flow rate, pump speed, or valve position to maintain the stable concentration of peracetic acid at the preset value. Automatic dosing can reduce the cost of reagent usage and improve the level of process control.

Power supply: 100-240VAC/0.75A
Language: Free choice of multiple languages
Input: Standard 4-channel sensor signal input, expandable to 16 channel input
Output: Standard RS485 output, 8 relay outputs, configurable 4-20mA output, expandable to 32 channels
Shell: Flame retardant ABS
Protection level: IP65
Size: 230 × 309 × 103
Weight: 2 kilograms
| sensor | BPES7 | BP9.2 |
BP10
|
| Type: | Diaphragm Ampere Polarographic Dual Electrode Sensor | Membrane Ampere Polarographic Dual Electrode Sensor | Membrane Ampere Polarographic Dual Electrode Sensor |
| Range: | 0.5-200,5-500,5-1000,5-2000,50-5000,50-10000 | 0-2%(20000ppm),0-200ppm,0-2000ppm, 0-5000ppm | 0-200ppm ,0-2000ppm 0-2%(20000ppm),0-5%(50000ppm) |
| Resolution: | 0.1,1,10(mg/L) | 0.001%(10ppm),0.1ppm,1 ppm | 0.1ppm , 1 ppm ,0.001%(0.001% 10ppm)0.01%(100ppm) |
| PH range: | PH1-6 | PH1-6 | PH1-6 |
| Temperature range: | 0-45 ℃ (no ice crystals in the measured water) | 0-60℃ | 0-45℃ |
| Temperature compensation: | Automatically completed by integrated temperature sensor | Integrated automatic temperature compensation | Integrated automatic temperature compensation |
| Pressure range: | 0.5bar, No pressure impact or vibration | 0-1Bar | 0-1Bar |
| First use polarization time: | About 3 hours | 30-180min | 24h |
| Response time: | T90, About 180 seconds | T90, About 3.5 minutes at around 10 ° C and 45 seconds at around 50 ° C | T90, around 1.5-5 minutes (depending on the sensor range and temperature) |
| Flow rate requirement: | About 0.5 liters per minute | 0.2-0.5L/Min, 15-30L/H at low flow rate | 0.2-0.5L/Min, 45 L/H at low flow rate |
| Material: | PVC, stainless steel | PEEK, Stainless steel 1.4571 | PVC-U, Stainless steel 1.4571 |
| Calibration: | Suggest calibrating once every 1-3 months | Suggest calibrating once every 1-3 months | Suggest calibrating once every 1-3 months |
| Interference: | Chlorine dioxide, * (hydrogen peroxide), ozone | Chlorine dioxide, * (hydrogen peroxide), ozone | Chlorine dioxide, * (hydrogen peroxide), ozone |