Palmitoyl whole protein immunoblot detection kit

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The palmitoyl whole protein immunoblot detection kit is used to detect all protein palmitoyl sites after quality inspection of the whole protein extraction. After the kit processing is completed, the immunoblot method is used to detect all protein palmitoyl sites.

Product Details

Item No.

AM10315

Product Name

Total protein-ABE-for WBPalmitoyl whole protein immunoblot detection kit

Product advantages:

Palmitoyl whole protein immunoblot detection kitAM10315 was developed for the detection of S-palmitoyl modification sites in most research tissues or cellular proteins. After extracting the whole protein and passing the quality inspection, the reagent kit is processed and all protein palmitoyl sites are detected by immunoblotting.

Product Features:

The detection process is relatively fast and convenient, and can detect possible S-palmitoyl protein modifications in all samples. The experimental operation is easy to operate and error free, and the results can be repeated after repeated testing

Operation steps:

Closed restoration marker detection

Reagent name_20rnxs:

LB Buffer,Reductant ,Blocking Reagent ,HAM+Reaction Buffer,HAM-Reaction Buffer,Biotin Reagent

Reagent No. 20rnxs:

Solution I,Solution II,Solution III,Solution IV,Solution V ,Solution VI

Volume_Form_20rnxs:

35mL ,600μL,2.5mL,1.2mL,1.2mL,2μL

Storage temperature_20rnxs:

4℃,4℃,4℃,4℃,4℃,4℃

Reagent name_4rnxs:

LB Buffer,Reductant,Blocking Reagent ,HAM+ Reaction Buffer,HAM-Reaction Buffer,Biotin Reagent

Reagent ID: 4rnxs

Solution I,Solution II,Solution III,Solution IV,Solution V ,Solution VI

Volume_Form_4rnxs:

7mL,150μL,500μL,250μL,250μL,5μL

Storage temperature: 4rnxs

4℃,4℃,4℃,4℃,4℃,4℃

Kit composition:

Reagent name (20rnxs) Reagent number Volume (formal) Storage temperature
LB Buffer Solution I 35mL 4℃
Reductant Solution II 600μL 4℃
Blocking Reagent Solution III 2.5mL 4℃
HAM+Reaction Buffer Solution IV 1.2mL 4℃
HAM-Reaction Buffer Solution V 1.2mL 4℃
Biotin Reagent Solution VI 2μL 4℃
Reagent name (4rnxs) Reagent number Volume (formal) Storage temperature
LB Buffer Solution I 7mL 4℃
Reductant Solution II 150μL 4℃
Blocking Reagent Solution III 500μL 4℃
HAM+ Reaction Buffer Solution IV 250μL 4℃
HAM-Reaction Buffer Solution V 250μL 4℃
Biotin Reagent Solution VI 5μL 4℃

FAQ

  • Product Receipt Confirmation

  • The insufficient volume of Solution II in the ABE (for WB) kit is due to the evaporation of some solvent ethanol, which can be supplemented with anhydrous ethanol to the corresponding volume; After receiving the product, some are in a dry powder state with only solutes. It is recommended to use and prepare it now.

    All products can be transported at room temperature for a short period of time without affecting the quality and effectiveness of the products. Aims product related after-sales support provides unconditional returns and exchanges due to quality issues.

    The product can be stored at -20 ℃ for long-term use and at 4 ℃ for short-term use.

    If there is any loss, damage, or leakage of reagents, do not use them and contact after-sales service.

    The StrePDAvin HRP reagent, due to its small packaging size, can be directly added to the corresponding laboratory incubation liquid and diluted proportionally before use.

  • Understand the experimental steps

  • If there are any problems or operational errors in any step of the reagent kit, you can contact the after-sales service. Some steps can be paused and restarted, and the operability is strong.

    Some of the parameters in the reagent kit are test parameters, please optimize them according to actual operating conditions for specific effects.

  • Product after-sales knowledge

  • If the product reagent kit is lost, damaged, or erroneous due to human factors, resulting in the inability to continue the experiment, the user of the product shall bear the responsibility, and the product owner may provide corresponding support and assistance to the purchaser of the reagent kit.

    The final use effect of the product is related to experimental factors such as personal use of antibodies and enrichment of captured beads. The interpretation right of the final product belongs to our company.

Introduction of Amperex Biotechnology Co., Ltd.:

Amperex Biotechnology Co., Ltd. has a very good reputation in the field of protein qualitative and quantitative sequencing such as MRM/SRM, iTRAQ, CoIP MS (protein interactions), acetylation/phosphorylation protein post-translational modifications, etc.

Five reasons to choose Amperex Biotechnology Co., Ltd

1. Committed to building a better proteomics research platform and providing better proteomics technologies

2. Extraction experience of multiple sample proteins (non model biological species such as corals, persimmons, bronchoalveolar lavage fluid, etc.)

3. Systematize laboratory management system and strictly control the quality process

4. Short project cycle, high-quality to meet customer needs

5. One on one responsibility system, with dedicated technical support for each project