The PFK-105 ionization test kit is a portable integrated testing system launched by Prostat, consisting of four core components: PFM-711B electrostatic field strength meter, CPM-7200B charging board monitoring device, PCS-730B ± 1 kV charger, and PDT-740B static decay timer. This kit is mainly used to test and evaluate the performance of ionization equipment (such as ion fans/ion rods) in industrial environments, including measuring two key indicators: ion equilibrium voltage (offset voltage) and discharge time.
This kit complies with the ionization standards ANSI/ESD S3.1 (test methods) and ANSI/ESD SP3.3 (periodic validation) of the ESD Association for ionizer balance adjustment and decay time measurement. In addition, it can also be used for measuring the generation and attenuation of body voltage, as well as evaluating the electrostatic properties of ionizers and packaging materials.
PFM-711B is a handheld electrostatic field measuring instrument mainly used for electrostatic investigation and surface polarity measurement of objects. Its core design adopts a stable chopper structure, which can measure in environments with ionized air without drift. The shell of the field strength meter is made of conductive material to provide grounding reference for the measurement circuit. During measurement, the measurement accuracy can be ensured by grounding with a wrist strap or a 10mm snap button on the back.
PFM-711B Technical Specifications:
| parameter | specification |
|---|---|
| display type | 3 and a half digit LCD display, with a digital height of 0.4 inches; Automatic polarity indication |
| High range | 0 to ± 19999 V, resolution 10 V (1 inch from charged surface) |
| low range | 0 to ± 1999 V, resolution 1 V (1 inch from charged surface) |
| Accuracy (laboratory environment) | ± 2% @ 23°C,30% RH |
| Accuracy (wide temperature range) | ± 5% @ 0-50 ° C, 0-85% RH (non condensing) |
| output interface | Analog signal output, ± 10.0 kV reading corresponds to ± 1 V output |
| Distance measuring lamp | Red bullseye type positioning light, used for positioning at a distance of 1 inch |
| Control buttons | Sampling/holding button, zero adjustment knob |
| Digital response speed | The display screen updates 3 times per second |
| Simulate output time constant | 0.1 seconds (any range) |
| Grounding method | Through conductive shell or 10mm snap button on the back |
| battery | 9 VDC magnetic battery, continuous working time ≥ 40 hours |
| size | 2.4' W × 4.2' L × 0.9' D(约6.1 cm × 10.7 cm × 2.3 cm) |
| weight | About 5 ounces (including battery, about 142 grams) |
CPM-72B is a 3.25-inch by 3.25-inch stainless steel isolation plate component that can be directly connected to the PFM-711B field strength meter, converting the field strength meter into a portable battery powered charging board monitoring system. When used in conjunction with the PCS-730B charger, performance evaluation of air ionization equipment can be achieved.
CPM-720A (early model)/720B Technical specifications:
| parameter | specification |
|---|---|
| Isolation board material and size | Stainless steel plate, 3.25 'x 3.25' (approximately 8.25 cm x 8.25 cm) |
| Plate capacitor | 10 pF ± 1 pF (isolation board only) |
| Combination capacitor | Approximately 15.8 pF (when installing PFM-711A/B) |
| Voltage measurement range | 0 to ± 6 kV (board separation distance 0.60 inches) |
| precision | ± 2% to 1000 V |
| weight | About 8 ounces (about 227 grams) |
PCS-730B is a portable electrostatic charger used to charge the CPM-72B charging pad to ± 1000 V for measuring the discharge time of ionizers in accordance with ANSI/ESD S3.1 and ANSI/ESD SP3.3 standards. After charging is completed, the charger automatically reduces its output to avoid overcharging the charging board.
PCS-730 (Type B) Technical specifications:
| parameter | specification |
|---|---|
| output voltage | ± 1000 V DC |
| output current limiting | ≤ 1 µA |
| Charging time | Charging to 1000 V<5 seconds |
| Output connector | Banana plug |
| size | 2.5 'W x 4.0' L (4.2 'including socket) x 1.5' D |
| weight | About 6 ounces (including battery, about 170 grams) |
PDT-740B is an electronic timer specifically designed for measuring the discharge time of ionizers. When used in conjunction with the PFM-711B field strength meter and PCS-730B charger, it can measure the discharge time of the ionizer - decay from ± 1000 V to below 100 V (in accordance with ANSI/ESD S3.1 standards), and further measure the time for the material to decay to below 50 V or below 10 V. There is a cut-off voltage selection switch on the timer panel, and users can choose to stop timing at three voltage thresholds of 10 V, 50 V, and 100 V.
PDT-740B Technical Specifications:
| parameter | specification |
|---|---|
| Optional cut-off voltage values | 10 V、50 V、100 V |
| Stop voltage selection | Select the cut-off voltage through the OFF-ON knob |
| Work Indicator Light | Green LED: ready, charging board voltage ≥ ± 1000 V; Red LED: timing in progress |
| Compatible voltage threshold | Measurement of attenuation time for ≤ 50 V and ≤ 10 V |
The PFK-100H bracket can combine the PFM-711B field strength meter, CPM-72B charging board, and PDT-740B decay timer into a handheld unit, making it easy to simultaneously measure the offset voltage and discharge time of ionization equipment during on-site testing.
According to the requirements of ANSI/ESD SP3.3 standard, ionization equipment needs to be regularly validated to ensure continuous maintenance of appropriate ion balance. The procedure for PFK-105 to perform this test is as follows: Connect the CPM-72B charging board to the PFM-711B field strength meter, place the assembly within the airflow range of the ion fan or ion rod, and read the voltage value displayed on the PFM-711B display screen, which is the current equilibrium voltage (offset voltage) of the ionizer. This value represents the degree of balance between the positive and negative ion outputs of the ionizer.
Discharge time is a key indicator for measuring the electrostatic neutralization ability of an ionizer, which characterizes the time required for the ionizer to drop a charged object from an initial voltage to a termination voltage. The test procedure is as follows: use the PCS-730B charger to charge the CPM-7200B charging board to ± 1000 V; place the charging board within the ionizer airflow range and start the PDT-740B timer at the same time; The timer stops counting from the moment the voltage reaches the selected voltage threshold (100 V, 50 V, or 10 V) and directly displays the decay time. This method complies with the specifications of ANSI/ESD S3.1 standard.
EPA (Electrostatic Protection Area) Environmental Maintenance VerificationPeriodically verify the ion balance state and discharge performance of the ionization fan and ionization rod to ensure compliance with ESD control requirements
Installation and acceptance of ionization equipmentInitial performance evaluation of newly installed or repaired ionization equipment
ESD Compliance Review and AuditPeriodic compliance verification and audit records of ESD control facilities in accordance with ANSI/ESD S3.1 and ANSI/ESD SP3.3 standards
Packaging material evaluationEvaluate the voltage generation and attenuation performance of static dissipation materials, anti-static packaging, and static shielding materials
Body voltage testMeasure the accumulation and dissipation time of body voltage during the walking or operation process of the operator, and evaluate the effectiveness of the personal grounding system
Research and Development and Product Quality ControlQuality control testing of ionization equipment performance in sensitive device processing areas in electronic component production environments
Automatic analysis system integrationPFK-105 can be paired with an X-Y plotter, analog data recording device, or PGA-710B automatic analysis system to record and analyze measurement data and generate reports
| parameter | specification |
|---|---|
| Kit type | Ionization testing system |
| Main functions | Ionizer balance debugging, discharge time measurement, body voltage testing, material voltage analysis |
| Applicable standard | ANSI/ESD S3.1 (Ionization Test Methods), ANSI/ESD SP3.3 (Periodic Validation) |
| Accuracy of field strength meter | ±2%(23°C / 30% RH); ±5%(0-50°C / 0-85% RH) |
| Measurement range of electrostatic field | Low range: 0-1999 V; High range: 0-19999 V (distance 1 inch) |
| Charging pad size | 3.25 'x 3.25' (8.25 cm x 8.25 cm) stainless steel plate |
| Charging board capacitor | Combination capacitance of approximately 15.8 pF (PFM-711A/B+CPM-720A/B) |
| charging voltage | ± 1000 V DC, charging time<5 seconds |
| Decay timer cut-off voltage | Users can choose between 100V, 50V, and 10V manually |
| power supply method | 9 V batteries (PFM-711B, PCS-730B); Internal power supply (PDT-740B) |
| PFM-711B battery life | Continuous operation ≥ 40 hours |
| Transportation/Storage Methods | Molded carrying case with foam inserts (supplied with kit) |
| Kit weight | About 5 pounds (including all components) |
PFM-711B electrostatic field strength meter (1 unit)
CPM-7200B charging board monitoring device (1 unit)
PCS-730B ± 1 kV charger (1 unit)
PDT-740B static decay timer (1 unit)
PFK-100H Instrument Bracket (1 piece)
Molded carrying case (with foam insert) (1 piece)