Welcome Customer !

Membership

Help

Shanghai Pumin Industrial Automation Equipment Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Shanghai Pumin Industrial Automation Equipment Co., Ltd

  • E-mail

  • Phone

  • Address

    Room 726, Building 2, No. 55 Meisheng Road, Pudong New Area Pilot Free Trade Zone, Shanghai (Baozhou Innovation Center)

Contact Now

PARKER plunger pump PV092R1K1T1WMMC Shanghai

NegotiableUpdate on 05/14
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

PARKER variable displacement piston pump PV092R1K1T1WMMC Shanghai $r $nPARKER variable displacement piston pump is mainly used for concrete conveying trucks, mixing trucks, truck mounted cranes, ship engines, excavators, etc. It can be used as a pump or motor for mobile machinery. This series of pumps has a proven spherical distribution plate high-performance rotating component with advantages such as automatic centering, low turnover rate, and high efficiency. Durable bearings and roller bearings help extend the working life, and the drive shaft can withstand radial loads. ISO installation flange, specifications starting from 55, PARKER variable displacement piston pump/motor and variable displacement motor remain unchanged

Product Details

PARKER plunger pump PV092R1K1T1WMMC Shanghai


PARKER variable displacement piston pumps are mainly used for concrete conveying trucks, mixer trucks, truck mounted cranes, ship engines, excavators, etc. They can be used as pumps or motors for mobile machinery. This series of pumps has a proven spherical distribution plate and high-performance rotating components with advantages such as automatic centering, low turnover rate, and high efficiency. Durable bearings and roller bearings help extend the working life, and the drive shaft can withstand radial loads. ISO installation flange, specifications starting from 55, PARKER variable displacement piston pump/motor and variable displacement motor remain consistent. Can use fire-resistant hydraulic oil with low noise.


Advantages of PARKER plunger pump PV092R1K1T1WMMC

High parameters: high rated pressure, high speed, high pump driving power.

Efficient: The plot ratio is about 95%, and the overall efficiency is about 90%.

Longer service life

Variables are convenient and diverse in form.

Single power is lighter in weight.

The main components of the plunger pump are subjected to compressive stress and can fully utilize the strength performance of the materials.


PARKER plunger pump PV092R1K1T1WMMC Shanghai

637922777980023424536.png


Characteristics of PARKER plunger pump PV092R1K1T1WMMC

Installation methods for British and metric systems.

Large variable control piston with strong reset spring, fast response speed.

Because the compensation system has an active release effect, the pressure peak decreases when the flow variable is zero.

It still has a stable compensating and regulating effect when the pressure is low.

The plunger design and the adoption of a new technology of preloading volume have reduced flow pulsation to unprecedented levelsLow level.

Durable and sturdy, the pump body structure optimized by FEM reduces noise levels.

Standard torque through shaft transmission structure.


PARKER plunger pump PV092R1K1T1WMMC structural form

PARKER piston pumps can be divided into two representative structural forms: axial piston pumps and radial piston pumps; Due to the fact that radial piston pumps are a new type of high-efficiency pump with high technological content, with the continuous acceleration of localization, radial piston pumps will inevitably become an important component of the application field of piston pumps; A radial piston pump is a piston pump in which the reciprocating motion direction of the piston or piston pump is perpendicular to the drive shaft.


Common series of Parker plunger pumps in the United States:

PV 系列:PV016, PV020, PV023, PV032, PV040, PV046, PV063, PV080, PV092, PV140, PV180, PV270 等.

Parker Double Axial Piston Pump PV016R1K1T1N Parker Double Axial Piston Pump PV023R1K1T1N PV032R1K1T1N

Parker dual axial piston pump PV040R1K1T1N Parker dual axial piston pump PV046R1K1T1N PV063R1K1T1N

Parker dual axial piston pump PV080R1K1T1N Parker dual axial piston pump PV092R1K1T1N PV140R1K1T1N

Parker dual axial piston pump PV180R1K1T1N Parker dual axial piston pump PV270R1K1T1N

Parker dual axial piston pump PV016R1K1T1NMR1

Parker dual axial piston pump PV046R1K1KJNMRW

Parker dual axial piston pump PV046R1K1S1NFWS

Parker dual axial piston pump PV092R1D1T1NMMC

Parker dual axial piston pump PV092R1K1T1NMMC

Parker dual axial piston pump PV140R1K1T1NFWS

Parker Dual Axial Piston Pump PV140R1K4T1VMMW-MOD (M14)

Parker dual axial piston pump PV180R1K1T1WFWS

Parker dual axial piston pump PV180R1K1T1NMMC

Parker dual axial piston pump PV180R1K8S1NFWS

Parker dual axial piston pump PV016RIK1T1NMMC

Parker dual axial piston pump PV016R1K1T1NMR1

Parker dual axial piston pump PV023RIK1T1NMMC

Parker dual axial piston pump PV032R1K1A4NFTZ

Parker dual axial piston pump PV032R1K1T1NELC

Parker dual axial piston pump PV046RIKITWWS

Parker dual axial piston pump PV046R1K1KJNMRW

Parker dual axial piston pump PV140R1K1T1NFRP

Parker dual axial piston pump PV140R1K1T1NMMC

Parker dual axial piston pump PV180RIK1T1NMMC

Parker dual axial piston pump PV180R1K1T1WFWS


Precautions for PARKER plunger pump

To ensure smooth operation of the PARKER plunger pump, the overlap of gear meshing must be greater than 1, so that there are always two pairs of gears meshing simultaneously and a set of oil between a closed chamber surrounded by a pair of gear teeth. The closed cavity gradually decreases as the gear rotates, and then gradually increases again. The reduction of the volume of the closed chamber will cause the trapped oil liquid to generate higher pressure during compression and squeeze out from the gap, resulting in the oil liquid heating up and bearing additional loads; At the same time, the increase in the volume of the enclosed chamber creates a local vacuum, causing the separation of dissolved gases in the oil and resulting in cavitation. This will cause strong vibration and noise, which is the phenomenon of trapped oil in the gear pump.