PARIO Plus Soil Particle Size Automatic AnalyzerCalculate the particle size distribution based on Stokes' law, with a measurement range of 63~2 μ m. The measurement method of PARIO is based on mature hydrometer or straw methods, using pressure sensors to continuously record pressure and temperature changes at specific locations in soil suspension at 10 second intervals, to obtain a complete soil particle size distribution curve.
Product Introduction
PARIO Plus Soil Particle Size Automatic AnalyzerOn the basis of PARIO, further improvements have been made, resulting in significant improvements in measurement accuracy and efficiency.
The revolutionary soil particle size analysis equipment PARIO developed by METER was launched in 2017. Compared with the traditional particle size analysis method PARIO, it shows an absolute advantage. The traditional hydrometer method (or straw method) takes 24 hours to manually operate, which is time-consuming, labor-intensive, and prone to errors. The laser particle size analyzer method is expensive, time-consuming, and has methodological deviations. After setting up PARIOPlus, the entire process will be automatically measured, and only the valve needs to be manually opened at the end of the measurement.
The measurement time has been shortened to only 2.5 hours, with an estimation error as low as ± 0.5%. PARIO Plus frees scientists' hands from complex experiments and allows them to fully devote themselves to the study of scientific problems.
Measuring principle
Calculate the particle size distribution based on Stokes' law, with a measurement range of 63~2 μ m. The measurement method of PARIO is based on mature hydrometer or straw methods, using pressure sensors to continuously record pressure and temperature changes at specific locations in soil suspension at 10 second intervals, to obtain a complete soil particle size distribution curve. PARIO Plus uses the more precise "Extended Integral Suspension Pressure Method" (ISP+) (Durner et al., 2017). In addition, PARIO based on Stokes' law does not require transfer function correction of soil properties, while almost any other automatic measurement method requires such correction, such as laser diffraction or image analysis.
Main Features
After setting up the fast measurement speed, the instrument only needs 2.5 hours to run.
The precise estimation error of the measurement method is as low as ± 0.5%, which is lower than any traditional particle size analysis method.
Automatic independent operation of PARIO allows for unmanned and automated operation, requiring only manual valve opening at the end of the experiment. Avoid manual reading and calculation errors.
Obtaining high-precision continuous particle size distribution curves is different from traditional methods that measure a few discrete time points. PARIO performs automatic measurements every 10 seconds and continuously records the pressure and temperature changes of the suspension.
The measurement process is undisturbed and does not require the insertion of a liquid density meter or the use of a pipette for sampling the suspension, thereby reducing disturbance to settlement.
Calculate the particle size distribution based on classical principles and Stokes' law, matching the traditional experimental preparation workflow.
√ Directly measure the clay content to obtain
√ Automatically calculate particle size distribution based on temperature synthesis
√ In order to save you more time, PARIO adopts a simple and easy-to-use integrated software solution, which easily realizes data query, visualization operation, data calculation and export.
Product Technical Parameters
Particle size range: 2~63 μ m
Approximate error of quality score detection: PARIO Plus: ± 0.5%; PARIO Classic: ±3.0%
Pressure measurement: accuracy: ± 1.0 Pa; resolution: ± 0.1 Pa
Typical particle mass: 25~50 g/1L suspension
Typical measurement duration: PARIO Plus: 3 hours; PARIO Classic: 8.0 h Measurement interval: 10 s
Estimation of clay content: obtained based on the comprehensive particle mass of the extracted sample
Estimation of sand content: obtained based on the results of wet sieving method measurement
Power requirement: USB 5 V/100 mA Computer compatibility: Microsoft Windows 10
Glass container specifications: height: 450.0 mm; inner diameter: 59.0 mm, outer diameter: 67.5 mm; volume: 1000 cm3; Material: borosilicate glass 3.3
PARIO Instrument: Height: 293.0 mm; Diameter: 80.0 mm; Material: POM plastic raw material and stainless steel
Suspension volume: 1000 mL
Working temperature: 15-35 ℃; Typical: 20 ℃
Maximum allowable temperature variation during measurement: ± 1.5 ℃
Additional parameters to be measured: PARIO Classic: organic matter content (if organic matter removal has been performed); Sand content (wet sieving method); The mass of dispersed salts in the total suspension
PARIO Plus: Sampling and measuring the total mass of dry matter; Sand content (wet sieving method); The mass of dispersed salts in the total suspension
Cable type: USB 2.0; 500 mA for receiving port
Compliant with standards: Production follows ISO 9001:2015; EM ISO/IEC 17050:2010 (CE Mark)