- Phone
-
Address
1709, 17th Floor, Building 4, Jiayue Plaza, Daxing District, Beijing
Beijing Ruiding Environmental Technology Co., Ltd
1709, 17th Floor, Building 4, Jiayue Plaza, Daxing District, Beijing
PARIO PlusAutomatic soil particle size analyzer
PARIO PlusAutomatic soil particle size analyzerOn the basis of PARIO, further improvements have been made, resulting in significant improvements in measurement accuracy and efficiency.
2017yearMETERRevolutionary soil particle size analysis equipment developedPARIOListed. Compared to traditional particle size analysis methodsPARIOwith obviousadvantage The traditional hydrometer method (or straw method) is time-consuming and manual24The laser particle size analyzer method is time-consuming, labor-intensive, and prone to errors. The equipment is expensive, time-consuming, and there are methodological deviations.PARIO PlusAfter setting up, the entire process will be automatically measured, and only the valve needs to be manually opened at the end of the measurement.
The measurement time has been shortened to only2.5Hours, with an estimated error as low as±0.5%.PARIO PlusLiberate scientists' hands from complex experiments and devote themselves wholeheartedly to the study of scientific problems.
Measuring principle
Based on Stokes' law(Stokes´ law)Calculate particle size distribution,Its measurement range is63~2 μm.PARIOThe measurement method is based on mature hydrometer or straw methods, using pressure sensors to10sContinuously record the pressure and temperature changes at specific locations in soil suspension at intervals to obtain a complete soil particle size distribution curve.PARIO PlusUse moreaccurateExactly“Extended Integral Suspension Pressure Method”(ISP+)(Durneret al., two thousand and seventeen). In addition, based on Stokes' lawPARIOThere is no need for transfer function correction of soil characteristics, which is required by almost any other automatic measurement method, such as laser diffraction or image analysis.
Main Features
u Fast measurement speed After setting up, the instrument only needs to run2.5Hour.
u measurement methodaccurate Low estimation errorto± 0.5%Lower than any traditional particle size analysis method.
u Automatic independent operation PARIOAllow unmanned and automated operation, only requiring manual valve opening at the end of the experiment.Avoid manual reading and calculation errors.
u Obtain high-precision continuous particle size distribution curve Unlike traditional methods that measure a small number of discrete time point data,PARIOeach10Perform an automatic measurement every second and continuously record the pressure and temperature changes of the suspension.
u Measurement process without disturbance No need to insert a hydrometer or use a pipette for sampling the suspension, thereby reducing disturbance to settling.
u According to classical principles According to Stokes' law(Stokes´ law)Calculate particle size distribution,just rightMatch the traditional experimental preparation workflow.
u Direct measurement of clay content
u Automatic comprehensive calculation of particle size distribution based on temperature
u Easy to use In order for you to save more time,PARIOAdopting a user-friendly software solution to easily achieve data queries, visualization operations, data calculations, and exports.
technical indicators
particle size range |
2 ~ 63 μm |
Approximate error in quality score detection |
PARIO Plus: ±0.5%;PARIO Classic: ±3.0% |
pressure measurement |
Accuracy:±1.0 PaResolution:±0.1 Pa |
Typical particle mass |
25 ~ 50 g/ 1Lsuspension |
Typical measurement duration |
PARIO Plus: 2.5 h;PARIO Classic: 8.0 h |
measurement interval |
10 s |
Estimation of clay content |
Obtain comprehensive particle quality based on extracted samples |
Estimation of Sand Content |
According to the wet sieving method, the results were obtained |
power supply demand |
USB 5 V/100 mA |
Computer compatibility |
MicrosoftWindows 10 |
Glass container specifications |
High:450.0 mm; Inner diameter:59.0 mmOuter diameter:67.5 mm; Volume:1,000 cm3 Material: borosilicate glass3.3 |
PARIOinstrument |
Height:293.0 mm; Diameter:80.0 mm; Material:POMPlastic raw materials and stainless steel |
Suspension volume |
1000 mL |
Operating Temperature |
minimum:15℃Typical:20℃; Maximum:35℃ |
Maximum allowable temperature variation during measurement |
±1.5℃ |
Parameters that require additional measurement |
PARIO Classic: organic matter content(If organic matter removal has been carried out)Sand content(Wet sieving method)The mass of dispersed salts in the total suspension |
PARIO Plus: Sampling and measuring the total mass of dry matter; Sand content(Wet sieving method)The mass of dispersed salts in the total suspension | |
Cable type |
USB 2.0;500 mAUsed for receiving ports |
meet the standard |
Production followsISO 9001:2015;EM ISO/IEC 17050:2010 (CE Mark) |
Origin and Manufacturer:beautycountryMETERcompany