Welcome Customer !

Membership

Help

Chengde Kaosi Scientific Testing Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Oxygen index analyzer

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The XYS-75F oxygen index tester is applicable to the combustion performance measurement of plastic, rubber, fiber, foam plastic, film, film, textile and other materials.

Product Details

XYS-75FOxygen Indexmeasuring instrument

1Scope of application:

It is applicable to the determination of combustion performance of plastics, rubber, fiber, foamed plastics, film, film, textile and other materials

IIMain technical parameters:

1adoptEnglandCity imported originalOxygen sensor, digital display of oxygen concentration without calculation, higher accuracy and precision, range of 0100%

2digitalResolution: ± 0.1%

3measurementAccuracy: 04Grade

4Flow regulation range:0-10L/min

5Response time:<5S

6Combustion cylinderThe size and height are500±50mm,Inner diameter ¢75mm-ф100mm,Export inner diameter: 40mmAt the topThere is a 10mm contraction opening.

7Inside the combustion cylindermixedGas flow rate: 40mm ±2mm/s

8Inside the combustion cylinderMixed gas temperature:23℃±2℃

9Pressure gauge accuracy level 2.5Resolution: 0.01MPa

10Flowmeter:1-15L/min(60-900L/HadjustableExperimental environment:Environmental temperature: room temperature~40 ℃;Relative humidity: ≤ 70%;

11Input pressure: 0.2-0.3MPa

12working pressure:nitrogen0.1-0.15MpaOxygen 0.1-0.15Mpa

13Oxygen/nitrogen mixed gas inlet: including stabilizing valve, flow regulating valve, gas filter, and mixing chamber.

14Sample clamp can be used for both soft and hard plasticsTextiles, fire doors, etc

15Propane (butane) ignition system, flame length 5mm-20mm adjustable freely

16Gas:Industrial nitrogen and oxygen, purity>99%; (User provided).

17Power requirements:AC220(+10% )V、50HZ

18Maximum power consumption:50W

19Igniter: There is onebrass tubeMade with a nozzle with an inner diameter of Φ 2 ± 1mm at the tail end, which can be inserted into the combustion cylinder to ignite the sampleThe nozzle can bend freely; Flame length: 16 ± 4mm, flameAdjustable size,

20Porous mesh: Metal wire mesh with a diameter of 80mm and a thickness of 0.5mm; Stainless steel mesh partition: diameter 73mm, thickness 1.2mm, uniformly distributed with small holes of diameter 2mm on top

21Self supporting material sample clamp: can be fixed at the axis position of the combustion cylinderAnd it can vertically clamp the sample

22Non self-supporting material specimen clamp: capable of fixing both vertical edges of the specimen to the frame simultaneously(Optional, suitable for soft materials such as textiles)

23Timer: Measurement time can reach 0~999min, accuracy 0.5S

24The temperature control part adopts electronic cooling and heating technology, and the temperature is controlled within23 ± 2 ℃, no compressor or heating tube is required for temperature rise and fall, reducing noise and instrument size (optional)

25Smoke exhaust system: ventilation device

26Film roll tool: A stainless steel bar with a gap at one end and a diameter of 2mm.

Chassis and Partial Structure:

1. Control box: processed and formed by CNC machine tools, electrostatic spraying, beautiful, rust proof and anti-corrosion. Separate control of control and experimental parts, including a separate ventilation device

2. Combustion cylinder:The size and height are500±50mm,Inner diameter ¢75mm-ф100mmInner diameter of outlet: 40mmThere is a 10mm contraction opening at the top.

3. Box size:Length 83cm * width 30cm * height 107cm, ventilation device length 44cm * width 28cm * height 100cm

4.Mixer: Using glass bead filling to evenly mix oxygen and nitrogen. (Bead diameter 4.5mm, filling height 95mm, one bag)

5Sample fixture: self-supporting fixture that can vertically clamp the sample; Standard non self-supporting style rackTwo sets of style clips meet different testing requirements; Style clip plug-in type, making it easier to place styles and style clips

6.Standard spare glass tube to prevent accidental damage and meet uninterrupted testing requirements; The diameter of the tail pipe hole of the long rod igniter is ¢ 2 ± 1mm,Igniter flame length (5-50) mm can be adjusted freely

7The new model is equipped with a level and electronic timer according to the latest standards.

Design standards:GB/T 2406.2-2009 ISO4589.3-1996

Compliant with standards:ASTM D 2863, ISO 4589-2, NES 714 GB/T 5454 GB/T 10707 GB/T 8924-2005 GB/T 16581-1996 NB/SH/T 0815-2010 TB/T 2919-1998 IEC 61144-1992 ISO 15705-2002 ISO 4589-2-1996ISO4589.3-1996

One bottle of industrial grade oxygen/nitrogen is used as the gas source, but as these gases are high-risk transport goods, they cannot be used asOxygen index analyzerThe accessories can only be purchased at the user's local gas station. To ensure the purity of the gas, please purchase it at a local regular gas station