- Phone
-
Address
No. 79, Road 3, Private Industrial Park, Jianhu County
Yancheng Siyuan Water Supply and Drainage Equipment Co., Ltd
No. 79, Road 3, Private Industrial Park, Jianhu County
Overall description of anti floating integrated fire water tank pump stationIn order to meet the needs of the fire market or meet special circumstances for fire water tanks, Yancheng Siyuan provides customized drawings or specialized project design services to meet different customer requirements. Customized buried box pump integrated water tank can be large or small for customers. The commonly used specification block for anti floating integrated fire water tank pump stations is 1 * 1m/1m * 0.5m. From large water supply companies, buildings, and residences to small buried water tanks that may only be used for households, it adopts prefabricated installation and is buried underground (with greening above) to save ground costs and increase the efficiency of fire prevention while effectively saving the entire project cost!

The foundation construction method in the buried integrated fire pump station is very important, and a series of processes such as excavation, cushion layer, reinforcement, formwork support, plastering, and demoulding are all completed by the civil engineering of the demand side. Its production is reliable, which is related to the progress of the installation personnel of the water tank manufacturer during installation. We often encounter such situations on site. When the installation master of the manufacturer arrives at the site for the first inspection, they find that the size of the foundation, the size and flatness of the foundation slot do not meet the requirements, which leads to rectification and delays in the construction period. Of course, there are also deviations in the laying position of the embedded parts, which are all very noteworthy issues.
By controlling the cooling rate of the steel plate after leaving the zinc pot in the hot-dip galvanizing process, the good grain orientation of the coating is adjusted to increase the adhesion of the coating. This method specifically involves hot-dip galvanizing the steel plate after acid pickling and annealing; During the hot-dip galvanizing process, the temperature of the steel plate when entering the plating bath is 55-465 ℃, the temperature of the plating bath in the zinc pot is 450-460 ℃, the Fe content in the plating bath is less than 0.03%, the Al content in the plating bath is 0.16-0.18%, the speed of the steel plate unit is 110-120m/min, and the steel plate is forced to cool by air cooling after leaving the zinc pot, with a cooling rate of 70-90%. Such process conditions result in the formation of oriented Zn (002) grains between the steel plate and the zinc coating, increasing the adhesion and scratch resistance of the coating.

Function of anti floating integrated fire water tank pump station:
1. No need to build a pump room, saving space
2. Adopting a silent fire pump set, it operates without noise, is energy-saving and environmentally friendly
3. Install all fire pump units in the water tank with noise reduction and antifreeze functions
4. During equipment maintenance, there is no need to discharge fire-fighting water from the water tank, saving energy
5. Equipped with water tank shortage alarm, automatic switching of fault alarm, and fire linkage function

In the past few years, it should be seen that the technological development trend of the integrated buried box pump industry is increasingly consistent with the global water supply equipment industry. However, the overall technical level is relatively low, and in the product field with high content of high, precision, and cutting-edge technology, there is no demand for water supply equipment products. In the past few years, the industry's focus has been more on anti buoyancy and anti compression, and this problem has gradually been solved. At present, the most commonly used integrated pump station is the anti floating buried fire box pump station, which is also known as the bottomless fire pump station, which can effectively prevent the pump station from floating up.
Overall description of anti floating integrated fire water tank pump stationThe buried integrated water supply equipment is a complete set of integrated equipment, mainly including prefabricated water tanks and integral pump rooms. The quality and installation of the water tank directly affect the service life of the entire pump station to a certain extent. Therefore, the selection of water tank materials and qualified installation teams must be taken seriously. There is currently a new type of integrated water supply equipment for buried box pumps, which uses a large module water tank without connections or horizontal connections, which effectively increases the spacing between water tanks and truly achieves energy conservation, environmental protection, and safety. Simply put, the entire pump station is an integrated fire box pump.