Optris high-temperature resistant infrared thermometer $r $nOPTCTLThot high-temperature probe series infrared thermometer $r $noptris CThot LT type high-temperature thermometer is designed for harsh conditions in high-temperature areas and has received high praise for its high temperature resistance. Up to 250 #176; Using an infrared thermometer at ambient temperature C does not require cooling and will not cause any problems. Due to the above characteristics, infrared thermometers are particularly suitable for drying machines, metal and glass industry tempering, plastic and textile processing, and semiconductor production.

Product Details

Optris high-temperature resistant infrared thermometer


OPTCTLThot high-temperature resistant probe series infrared thermometer

The Optris CThot LT high-temperature thermometer is designed specifically for harsh conditions in high-temperature areas and has received high praise for its exceptional resistance to high temperatures. Using an infrared thermometer at ambient temperatures up to 250 ° C does not require cooling and will not cause any problems.

Due to the above characteristics, infrared thermometers are particularly suitable for drying machines, metal and glass industry tempering, plastic and textile processing, and semiconductor production.


638460075017986848527.jpg


Optris CThot LT type high ambient temperature specialized high-temperature thermometer

Product Specifications

measurement parameters


Temperature range (measured through setting keys or software)

-40°C ~ 975 °C

spectral range

8 ~14 µm

Optical resolution (90% energy)

0:1; 2:1

System accuracy (Note 1) (ambient temperature=23 ± 5 ° C)

± 1% or ± 1.5 ° C (Note 2)

Repetition accuracy (Note 1) (ambient temperature=23 ± 5 ° C)

± 0.5% or ± 0.5 ° C (Note 2)

Temperature resolution (noise equivalent temperature difference)

0.25°C

response time

100 ms

Emissivity/gain (adjusted by setting keys or software)

0.100 ~ 1.100

Transmittance/gain (adjusted by setting keys or software)

0.100 ~ 1.100

Signal processing (specific parameters can be adjusted through setting keys or software)

Peak hold, valley hold, average, extended hold threshold, and lag function

Basic Parameters


environmental level

IP65(NEMA-4)

ambient temperature

Probe: -20 ° C~250 ° C; Electronic box: 0 ° C~85 ° C

Storage temperature

Probe: -40 ° C~250 ° C; Electronic box: -40 ° C~85 ° C

relative humidity

10~95%, no condensation

vibration

-IEC 60068-2-6 (sinusoidal waveform); -IEC 60068-2-64 (Broadband Noise)

impact

-IEC 60068-2-27 (25G and 50G)

weight

Probe: 40 g (without large casing); Electronic box: 420 g

Electrical parameters


analog output

Channel 1: 0/4-20mA, 0-5/10V, thermocouple J, K
Channel 2: Probe temperature (0-5 V or 0-10 V corresponds to -40-250 ° C), alarm output

alarm output

24 V/50 mA (normally open)

optional

Relay: 2 x 60 V DC/42 V AC; 0.4 A; optical isolation

Digital output (optional)

USB, RS232, RS485 (optional), Modbus RTU (serial communication protocol), Profibus DP (fieldbus multifunctional slave design)

Output impedance

MA Max 500 Ω (DC 8-36 V); MV Min 100 k Ω (pure impedance load); Thermocouple 20 Ω

signal input

Programmable function input, used for external emissivity setting/environmental temperature compensation, triggering (holding function reset)

cable length

3m (standard), 8m, 15m

power supply

DC 8-36 V

Current consumption

Max 100 mA

Note 1

Take the larger value

Note 2

Object temperature ≥ 20 ° C







638460075018611910804.jpg

Optris high-temperature resistant infrared thermometer



model
temperature range
temperature measurement accuracy
response time
distance coefficient
spectral response
Optctlt 02 H
-40~975℃
±1%±1.5℃
100ms
2:1
8~14μm
Optctlt 10 h
-40~975℃
±1%±1.5℃
100ms
10:1
8~14μm
Optctlt 10 HCF 1
-50~975℃ ±1%±1.5℃
100ms
3mm@30mm
8~14μm
Operating Temperature
Probe: -20~250 ℃, electronic box: -20~85 ℃
analog output
0/4-20mA, 0-5/10V, J/K type thermocouple signal output
digital output
USB、RS232,RS485,CAN-Bus,Profibus DP, Ethernet 可选
emissivity
0.100~1.100 software settings
Connecting cable length
1m, 3m, 8m, 15m optional
signal processing
Peak holding, valley holding, average value.
power supply
8~36VDC
application
Printing, painting, hot pressing, drying, vulcanization, papermaking, textiles, plastic films, asphalt, pharmaceuticals, electricity, grinding tools, metal secondary processing, heat treatment, new materials, various high-temperature furnaces, melting furnaces, sintering furnaces, induction heating, glass melting furnaces, heat treatment equipment, various brazing, laser welding, and laboratory research