Fluke temperature and humidity detector

NegotiableUpdate on 01/03
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Temperature, Humidity, and Environmental Testing Tool Fluke Temperature and Humidity Detector $r $nFluke 972A/972B/972ES Temperature and Humidity Detector $r $n Optional Standard or Optional External Probe, Flexible Response to Space Limitations $r $n Accuracy #177; 0.5℃, #177; 3%RH, To meet the needs of industrial testing, $r $n99 sets of stored data are available for convenient review (only for Fluke 972B). $r $n has an automatic recording mode, which enables up to 8 hours of automatic temperature and humidity monitoring (only for Fluke 972B). $r $n has a comfortable grip and an ergonomically designed sensor protective cover, ensuring worry free operation

Product Details

Temperature, humidity, and environmental testing toolsFluke temperature and humidity detector

Fluke 972A/972B/972ES Temperature and Humidity Detector

638459412332781894738.jpg

Key Features

  • Optional standard or optional external probe, flexible to cope with space limitations

  • Accuracy ± 0.5 ℃, ± 3% RH, to meet industrial testing requirements

  • 99 sets of stored data for convenient review (Fluke 972B only)

  • Automatic recording mode for up to 8 hours of automatic temperature and humidity monitoring (Fluke 972B only)

  • Comfortable grip and ergonomic design

  • Enhanced sensor protection cover ensures worry free operation

Follow the test and observe, industrial design, and regular inspection.

Temperature and humidity are two important testing items for indoor air comfort and environmental monitoring. The Fluke 972 series temperature and humidity detector can quickly and conveniently obtain humidity and temperature data. The streamlined industrial design is easy to hold, the streamlined operation buttons do not require more complex operations, and the sensors ensure reliable data. For equipment maintenance and engineering technicians, HVAC service contractors, R&D and production personnel, as well as those engaged in indoor air quality (IAQ) assessment, Fluke 972 is an environmental monitoring tool.

Product specifications: Fluke 972A/972B/972ES temperature and humidity detector


972A 972B 972ES
Detailed technical specifications
Sensor form built-in Internal+External external
Temperature range -30.0 ℃ to 65.0 ℃ Built in sensor: -30.0 ℃ to 65.0 ℃
External sensor: -40.0 ℃ to 99.9 ℃
-40.0 ℃ to 99.9 ℃
temperature accuracy ± 0.5 ℃ (-30.0 ℃ to 65.0 ℃) Built in sensor: ± 0.5 ℃ (-30.0 ℃ to 65.0 ℃)
External sensor: ± 0.5 ℃ (-30.0 ℃ to 65.0 ℃)
± 0.7 ℃ (other)
± 0.5 ℃ (-30.0 ℃ to 65.0 ℃)
± 0.7 ℃ (other)
temperature resolution 0.1 °C
dew point temperature range N/A -40.0 ° C to 99.9 ° C N/A
resolution N/A 0.1 °C N/A
wet-bulb temperature range N/A -20.0 ° C to 60.0 ° C N/A
resolution N/A 0.1 °C N/A
humidity range 0.0% RH to 99.9% RH
accuracy ± 3% RH (≥ 20.0% RH to ≤ 80.0% RH at 25 ℃)
± 5% RH (≥ 1% RH to<20% RH,>80% RH to ≤ 95% RH at 25 ℃)
other
resolution 0.1% RH
data saving N/A Yes, up to 99 sets of data N/A
display 2-line LCD display with backlight none
Auto Shutdown Automatically shut down after 20 minutes without any operation N/A
Maximum/Minimum/Average Value have have N/A
Automatic recording mode N/A have N/A
General technical indicators
temperature work -30 ° C to 70 ° C -40 ° C to 70 ° C
store -30 ° C to 70 ° C,<80% RH (excluding battery) -40 ° C to 70 ° C,<80% RH
altitude work 2000 m
store 12000 m
relative humidity work 0% RH to 99% RH
store <80% RH
power supply Battery Type 2 AAA batteries
battery life 1000 hours of continuous operation without backlight
safety IEC61010-1, Pollution level 2
Dimensions (length x width x height) 211 × 58 × 40 mm 264 × 33 × 28 mm
weight 172 g (bare metal) 127 g
Electromagnetic Environment (EMC) IEC 61326-1: Portable, Electromagnetic Environment: IEC 61326-2-2; CISPR 11: Group 1, Class A
Group 1: The device intentionally generates and/or uses conductive coupling RF energy, which is a necessary condition for the internal operation of the device itself.
Class A: The device is suitable for non household use and any device that is not directly connected to the low-voltage network that supplies power to residential buildings. Due to conducted and radiated interference, it may be difficult to ensure electromagnetic compatibility in other environments.
Caution: This device cannot be used in residential environments as it may not provide sufficient radio reception protection in such environments.
Protection (IP) level IEC 60529:IP30, Under non working conditions




638459412333094331998.jpg


Model: Fluke 972A/972B/972ES Temperature and Humidity DetectorFluke temperature and humidity detector

Fluke 972A/972B/972ES

Model: Fluke 972A/972B/972ES Temperature and Humidity Detector

Fluke 972A Temperature and Humidity Detector

random standard configuration

  • Fluke 972A Host

Fluke 972B Temperature and Humidity Detector

random standard configuration

  • Fluke 972B Host

  • Fluke 972ES external sensor

Fluke 972ES external temperature and humidity sensor

random standard configuration

  • Fluke 972ES external sensor