E-mail
13818624135@126.com
-
Phone
13818624135
-
Address
504, No. 14, Lane 550, Lianxi Road, Pudong New Area, Shanghai
Shanghai Kewang Industrial Co., Ltd
13818624135@126.com
13818624135
504, No. 14, Lane 550, Lianxi Road, Pudong New Area, Shanghai
Optris flame infrared thermometer CTlaser MTWith a special measurement wavelength, accurate temperature measurement is carried out through flames ranging from 200 ° C to 1650 ° C. Therefore, it is suitable for monitoring workpieces in ovens, measuring in chemical reactors, and testing refractory linings in kilns.
The stainless steel measuring head adopts dual laser goggles, which can mark measurement points at any distance at any time. Even small objects with a size of only 1.6mm can easily measure their temperature with an infrared thermometer.

Optris flame infrared thermometer CTlaser MT
Product Specifications
Repetitive accuracy (ambient temperature=23 ± 5 ° C) |
± 0.5% or ± 0.5 ° C (Note 2) |
Temperature resolution (digital) |
0.1°C |
Response time (90% signal) (Note 3) |
10 ms |
Emissivity/gain (adjusted by setting keys or software) |
0.100 ~ 1.100 |
Transmittance/gain (adjusted by setting keys or software) |
0.100 ~ 1.100 |
Signal processing (specific parameters can be adjusted through setting keys or software) |
Peak hold, valley hold, average, extended hold threshold, and lag function |
Basic Parameters |
|
environmental level |
IP65(NEMA-4) |
ambient temperature |
Probe: -20 ° C~85 ° C (laser on at 50 ° C); Electronic box: 0 ° C~85 ° C |
Storage temperature |
Probe: -40 ° C~85 ° C; Electronic box: -40 ° C~85 ° C |
relative humidity |
10~95%, no condensation |
Vibration (sensor) |
-IEC 60068-2-6 (sinusoidal waveform)/- IEC 60068-2-64 (wideband noise) |
Impact (sensor) |
-IEC 60068-2-27 (25G and 50G) |
weight |
Probe: 600 g; Electronic box: 420 g |
Electrical parameters |
|
analog output |
Channel 1: 0/4-20mA, 0-5/10V, thermocouple J, K |
alarm output |
0-24V/50 mA (normally open) |
optional |
Relay: 2 x 60 V DC/42 V AC; 0.4 A; optical isolation |
Digital output (optional) |
USB, RS232, RS485, Modbus RTU (serial communication protocol), Profibus DP (fieldbus multifunctional slave design), Ethernet |
Output impedance |
MA Max 500 Ω (DC 5-36 V); MV Min 100 k Ω (pure impedance load); Thermocouple 20 Ω |
signal input |
Programmable function input, used for external emissivity adjustment/environmental temperature compensation, triggering (holding function reset) |
cable length |
3m (standard), 8m, 15m |
power supply |
DC 8-36 V |
Current consumption |
Max 160 mA |
Laser 635 nm |
1mW, Open/close through electronic box or software |
Note 1 |
ε (emissivity)=1, response time: 1s |
Note 2 |
The temperature of the object is higher than 300 ° C |
Note 3 |
Dynamic adaptation at low signal levels |

| model |
temperature range |
temperature measurement accuracy |
response time |
distance coefficient |
spectral response |
| Optctlmt |
200~1450℃ |
±1% |
10ms |
45:1 | 3.9μm |
| Optctlmth |
400~1650℃ |
±1% |
10ms |
45:1 |
8~14μm |
| Measure the spot and focal length |
CF1: 1.6mm@70mm ;CF2 3.4mm@150mm ;CF3: 4.5mm@200mm
CF4: 10mm@450mm ;SF: 27mm@1200mm
|
||||
| Operating Temperature |
Probe: -20~85 ℃, electronic box: 0~85 ℃ |
||||
| analog output |
0/4-20mA, 0-5/10V, J/K type thermocouple signal output |
||||
| digital output |
USB、RS232,RS485,CAN-Bus,Profibus DP, Ethernet 可选 |
||||
| emissivity |
0.100~1.100 software settings |
||||
| Connecting cable length |
3m, 8m, 15m optional |
||||
| signal processing |
Peak holding, valley holding, average value. |
||||
| power supply |
8~36VDC |
||||
| application |
Measuring workpiece temperature through flame: measurement of heat treatment temperature and heating furnace temperature | ||||