Optris flame infrared thermometer CTlaser MT

NegotiableUpdate on 01/03
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The Optris flame infrared thermometer CTlaser MT from Optris has a special measurement wavelength and can measure temperatures through 200 ° C; C to 1650 Accurate temperature measurement of C flame. Therefore, it is suitable for monitoring workpieces in ovens, measuring in chemical reactors, and testing refractory linings in kilns. The $r $n stainless steel probe adopts dual laser goggles, which can mark measurement points at any distance at any time. Even small objects with a size of only 1.6mm can easily measure their temperature with an infrared thermometer.

Product Details

Optris flame infrared thermometer CTlaser MTWith a special measurement wavelength, accurate temperature measurement is carried out through flames ranging from 200 ° C to 1650 ° C. Therefore, it is suitable for monitoring workpieces in ovens, measuring in chemical reactors, and testing refractory linings in kilns.

The stainless steel measuring head adopts dual laser goggles, which can mark measurement points at any distance at any time. Even small objects with a size of only 1.6mm can easily measure their temperature with an infrared thermometer.

638467150991989720938.jpg

Optris flame infrared thermometer CTlaser MT

Product Specifications

measurement parameters


Temperature range (measured through setting keys or software)

200°C ~ 1450°C

spectral range

3.9 µm

Optical resolution (90% energy)

45:1

Optional Focus

CF1 1.6 mm @70 mm
CF2 3.4 mm @ 150 mm
CF3 4.5 mm @ 200 mm
CF4 10 mm @ 450 mm
SF 27 mm @ 1200 mm

System accuracy (Note 1)
(Environmental temperature=23 ± 5 ° C)

± 1% (Note 2)

Repetitive accuracy (ambient temperature=23 ± 5 ° C)

± 0.5% or ± 0.5 ° C (Note 2)

Temperature resolution (digital)

0.1°C

Response time (90% signal) (Note 3)

10 ms

Emissivity/gain (adjusted by setting keys or software)

0.100 ~ 1.100

Transmittance/gain (adjusted by setting keys or software)

0.100 ~ 1.100

Signal processing (specific parameters can be adjusted through setting keys or software)

Peak hold, valley hold, average, extended hold threshold, and lag function

Basic Parameters


environmental level

IP65(NEMA-4)

ambient temperature

Probe: -20 ° C~85 ° C (laser on at 50 ° C); Electronic box: 0 ° C~85 ° C

Storage temperature

Probe: -40 ° C~85 ° C; Electronic box: -40 ° C~85 ° C

relative humidity

10~95%, no condensation

Vibration (sensor)

-IEC 60068-2-6 (sinusoidal waveform)/- IEC 60068-2-64 (wideband noise)

Impact (sensor)

-IEC 60068-2-27 (25G and 50G)

weight

Probe: 600 g; Electronic box: 420 g

Electrical parameters


analog output

Channel 1: 0/4-20mA, 0-5/10V, thermocouple J, K
Channel 2: Probe temperature (0-5 V or 0-10 V corresponds to -20-85 ° C), alarm output

alarm output

0-24V/50 mA (normally open)

optional

Relay: 2 x 60 V DC/42 V AC; 0.4 A; optical isolation

Digital output (optional)

USB, RS232, RS485, Modbus RTU (serial communication protocol), Profibus DP (fieldbus multifunctional slave design), Ethernet

Output impedance

MA Max 500 Ω (DC 5-36 V); MV Min 100 k Ω (pure impedance load); Thermocouple 20 Ω

signal input

Programmable function input, used for external emissivity adjustment/environmental temperature compensation, triggering (holding function reset)

cable length

3m (standard), 8m, 15m

power supply

DC 8-36 V

Current consumption

Max 160 mA

Laser 635 nm

1mW, Open/close through electronic box or software

Note 1

ε (emissivity)=1, response time: 1s

Note 2

The temperature of the object is higher than 300 ° C

Note 3

Dynamic adaptation at low signal levels

638467150992770907938.jpg

OPTLaserMT flame specific series infrared thermometer

model
temperature range
temperature measurement accuracy
response time
distance coefficient
spectral response
Optctlmt
200~1450℃
±1%
10ms
45:1 3.9μm
Optctlmth
400~1650℃
±1%
10ms
45:1
8~14μm
Measure the spot and focal length
CF1: 1.6mm@70mm ;CF2 3.4mm@150mm ;CF3: 4.5mm@200mm
CF4: 10mm@450mm ;SF: 27mm@1200mm
Operating Temperature
Probe: -20~85 ℃, electronic box: 0~85 ℃
analog output
0/4-20mA, 0-5/10V, J/K type thermocouple signal output
digital output
USB、RS232,RS485,CAN-Bus,Profibus DP, Ethernet 可选
emissivity
0.100~1.100 software settings
Connecting cable length
3m, 8m, 15m optional
signal processing
Peak holding, valley holding, average value.
power supply
8~36VDC
application
Measuring workpiece temperature through flame: measurement of heat treatment temperature and heating furnace temperature