Olympus fully automatic cleanliness inspection microscope

NegotiableUpdate on 05/07
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The CIX100 Olympus fully automatic cleanliness inspection microscope is a specialized turnkey solution suitable for manufacturers who require high quality standards for the cleanliness of manufactured components.

Product Details

CIX100Olympus fully automatic cleanliness inspection microscopeIt is a specialized turnkey solution suitable for manufacturers who require high quality standards for the cleanliness of manufactured components. Quickly obtain, process, and record technical cleanliness testing data to meet the requirements of the company and international standards. The intuitive software of this system can guide users to complete each step of the process, so even novice operators can quickly and easily obtain cleanliness data.

CIX100 Olympus fully automatic cleanliness detection microscope simplifies technology cleanliness
Ensuring that components, workpieces, and fluids have qualified cleanliness is the core of the manufacturing process. Achieving high standards in the counting, analysis, and classification of pollutants and foreign objects, mostly in the micrometer scale, is crucial for various workflows such as final product development, manufacturing, production, and quality control. Various international and national directives describe methods and record requirements for determining particle contamination on basic machined parts, as particle contamination directly affects the service life of workpieces and components. The current standards require detailed information on the nature of pollution, such as the number of particles, particle size distribution, and particle characteristics. Intended to meet the cleanliness requirements of modern industry as well as national and international directives.
标准的清洁度检测流程

Standard cleanliness testing process
The standard cleanliness testing process includes preparation (steps 1-3) and testing (steps 4-6). Step 1: Extraction, Step 2: Filtering, Step 3: Weighing, Step 4: Detection, Step 5: Review, Step 6: Results.


1、 Simple and reliable
Seamless integration of hardware and software to create a durable and efficient system that can provide reliable and accurate data
1. Easy to set up automated, turnkey solutions;
2. A stable measurement system setup is beneficial for providing reproducible results;
3. Excellent optical performance and reproducible imaging conditions;
4. The automation system performs self inspection through an integrated calibration device;
5. System wide integration to achieve automated control of all hardware components;
6. Support various circular and rectangular sample racks;
通过直观的指导提高生产力.jpg
2、 Improve productivity through intuitive guidance
Dedicated and simple workflow can reduce user operations and provide reliable data - independent of operator and experience level
1. Easily modify detection data with easy-to-use tools;
2. Step by step guidance can improve productivity and shorten testing time;
3. User permission management can limit functionality to minimize human errors;
4. Touchscreen displays large-sized buttons that are easy to click;
5. One click report that meets the requirements, achieving efficient file recording;
6. All data is automatically saved and can be easily exported and shared;
7. Adopting an independent microscope mode with optional material analysis solutions;
快速实时分析.jpg

3、 Fast real-time analysis
The innovative integrated scanning solution detects reflective (metal) and non reflective particles at twice the speed of traditional methods that require two independent images. Instant feedback on particle counting and classification information can help you make quick decisions
1. Overview image for quickly identifying filter membrane range, particle clusters, or worst particles;
2. Regarding 2.5? Automatic real-time processing and classification of pollutant particles within the range of m to 42 mm;
3. Efficient: The system detects both reflective and non reflective particles in one scan;
4. Real time analysis enables you to respond in real-time to the results;
5. Customizable results that meet the requirements according to selected industry standards;

4、 Effective data evaluation
The CIX100 fully automatic cleanliness detection microscope uses easy-to-use tools to modify detection data, supporting company and international cleanliness detection standards. Clearly present all relevant test results to save time
1. The organized arrangement of images and data enhances the efficiency of data review;
2. Various views can be selected to immediately identify particles;
3. Linking particle positions and thumbnails to real-time images;
4. Easily reclassify, review, modify, and recalculate detection data;
5. Real time display of overall cleanliness codes, particles, and classification tables;
6. Trend analysis to identify potential measurement biases that may arise over time;
7. Display complete detection data in one view;
有效的数据评估.jpg

5、 Create compliance report
The one click report production method complies with the requirements and methods outlined in international standards. The report can be customized (for example, including particle morphology) to easily meet specific standards of different companies
1. Generate professional reports using pre-defined compliance templates;
2. Easily adjust templates and reports to meet industry and company regulations;
3. Supports various output formats, including MS Word and PDF;
4. The report file size has been optimized for easy result sharing;
5. Long term data storage allows you to prove the rationality of your decisions years later;

创建合规报告.jpg