Nonlinear linear programmable rapid temperature change test chamberTemperature cycling stress screening is the process of using temperature acceleration techniques to cycle products within the extreme temperatures of the upper and lower limits under the design strength limit. When the product undergoes alternating expansion and contraction, it changes the external environmental stress, causing thermal stress and strain in the product. By accelerating the stress, potential defects in the product (such as material defects, process defects, and process defects) are exposed to avoid unnecessary losses caused by environmental stress testing during use. It has a significant effect on improving product delivery yield and reducing repair times. In addition, stress screening itself is a process stage rather than a reliability test, so stress screening is a process of testing the product. The program.
Nonlinear linear programmable rapid temperature change test chamber
Stress screening temperature variation rates of 5 ℃/min, 10 ℃/min, 15 ℃/min, 20 ℃/min, etc. are optional and customizable
◆ Can perform rapid temperature change (stress screening), condensation test, high temperature and high humidity, temperature and humidity cycling Waiting for various experiments
The online control system has anti misoperation and electromagnetic interference functions
◆ Effectively achieve the effects of low noise, low energy consumption, energy conservation, and carbon reduction
Adopting the new PWM refrigeration control technology from the United States to achieve low-temperature energy-saving operation
◆ Storage analysis function, equipped with R485, 232, Ethernet interface connection
Multiple alarm detection on the machine, equipped with wireless remote alarm function
The humidity water is supplied by a new RO reverse osmosis water filter automatic water supply device
Meet the execution standards:
1. GB2423.1-89 Test A Low temperature test method
2. GB2423.2-89 Test B High temperature test method
3. IEC68-2-1 Test A
4. IEC68-2-1 Test B
5. GJB1032-90 Environmental Stress Screening Method