NitraLyt Plus 700IQ Nitrous NO3-N Online Sensor

NegotiableUpdate on 05/16
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Instrument: Nitrous NO3-N Online Sensor Model: NitraLytPlus700IQ Measurement Principle: Ion Selective Electrode Brand: WTW Germany

Product Details

    characteristic

    • Three models
      -AmmoLyt ® PlusAmmonia nitrogen sensor
      - NitraLyt ® Plus Nitrous nitrogen sensor
      - Varion® Plus Ammonia nitrogen/Nitrogen nitrate two in one sensor

    • No need to fill electrolyte and replace ion membrane

    • Automatically compensate for the impact of interfering ions

    • On site continuous monitoring sensor technology

    • Quick response, no lag time

    • Automatic monitoring of biochemical treatment process

    • Multi directional monitoring of nitrogen removal process throughout the entire process

    • Automatic air blowing system ensures long-term reliable operation

    • Very economical and practical

    • No need for calibration, good long-term stability

    • No reagent consumption, low investment and maintenance costs



    application

    In the process of biochemical degradation and denitrification in sewage treatment plants, in addition to dissolved oxygen, there are two important analytical parameters that cannot be ignored, which are ammonia nitrogen and nitrate nitrogen. These parameters play a crucial role in achieving high treatment efficiency and effectiveness of sewage treatment plants under low energy consumption. These three parameters are interrelated, and the adjustment of their concentration correspondence directly affects the effectiveness of sewage treatment and the power consumption of the blower.

    useSBRTaking the processing technology as an example, as shown in the figure1The time concentration correspondence between these three parameters in nitrification and denitrification processes. During the nitrification process, the blower introduces sufficient air, causing the dissolved oxygen concentration to increase and maintain at around2mg/lAt this average level, the concentration of ammonia nitrogen will gradually decrease, while the concentration of nitrate nitrogen will correspondingly increase. During the denitrification process, the blower stops working and the dissolved oxygen slowly decreases to0mg/lThe nitrate nitrogen is gradually reduced to nitrogen gas, and the nitrogen removal process is successfully completed. At the same time, the concentration of ammonia nitrogen in the sewage gradually increases. Real time detection of ammonia in the water during this reaction processNH4+And nitrate nitrogenNO3-The concentration of dissolved oxygen can be accurately controlled in the process. I used to use it frequently beforeORPThis parameter is used to monitor and control nitrification and denitrification processes, butORPThis parameter is easily affected by various oxidative factors in the water body, and its performance is unstable, especially the difficulty of determining inflection points, which often leads to misoperation and premature termination of denitrification processes.



    Automatically compensate for the impact of interfering ions

    There are two main interfering ions: chloride ions can interfere with nitrate nitrogen testing; Potassium ions can interfere with the testing of ammonia nitrogen.10mg/lPotassium ions will approximately contribute0.7mg/lThe ammonia nitrogen reading,100mg/lChloride ions will contribute approximately0.7mg/lThe nitrate nitrogen reading. Ammonia nitrogen and nitrate nitrogen at low concentrations (less than)10mg/l)The measurement is more affected, therefore, additional chloride or potassium ion electrodes need to be selected to compensate for the interference of ions.

    Calibration free testing

    After installing the corresponding ion electrode,Ammolyt plus /NitraLyt plus /VARiON plus700 IQSensors can be tested immediately without calibration. If the requirements are strict, just follow themOn site water sample calibration "is sufficient, it is very simple, and the sensor does not need to be taken out of the water sample. Users only need to compare with the laboratory photometry method at regular intervals, and if there is any deviation, then perform "on-site water sample calibration". In addition to on-site water sample calibration, standard solutions can also be selected2Point correction (note: usually not required). Through calibration, the system automatically evaluates the performance of various electrodes2Individual performance indicators, namely drift potential and slope. If this2If the indicators fall within the permitted range, it indicates that the correction is successful. The scope of the license is
    Slope:50…70 mVZero drift potential:-45…+45 mV.


    System Introduction

    oneComplete setAmmonia nitrogen/nitrateThe system is composed ofIQ SENSOR NETTransmitterSensor housing components, reference electrode, working electrodeIQCable lineComposed of air cleaning components. The above-mentioned components can be replaced easily, without the need to fill electrolyte or replace thin films! Automatic cleaning passed37The compressed air of Ba is realized by a dedicated systemMIQ/CHVThe solenoid valve control module is used to control the air circuit switch.

    During testing, as long as the corresponding ion selective electrode is inserted into the corresponding socket of the sensor, the remaining work is automatically completed by the sensor. The instrument directly displays the correct test value, or you can choose to display the concentration value of interfering ions, such as potassium ion concentration. All test values can be obtained by simulating current0/4-20 mAOr digital interfacePROFIBUSperhapsMODBUSTransfer toPLCIn the system.

    measuring principle

    Ion selective electrode methodISEIn principle, the construction of the instrument can be relatively simple, and the measurement can achieve rapid response. However, when1991When the ammonia ion testing method appeared, it could only be applied to laboratory analysis because operators needed to have specific operating skills, strictly preprocess samples, adjust the ion strength of solutions, and maintain constant temperature testing. At that time, it was widely believed that the ion selective electrode method was not suitable for online monitoring.

    But in2002There has been a qualitative change in the annual situation,WTWSuccessfully developed and releasedAmmoLytThe ammonia ion online selection electrode analyzer uses electrode membranes, electrolytes, and reaction electrodes made of special materials. In order to avoid interference from potassium ions on the measurement of ammonium ions, a dedicated potassium ion measurement electrode is also installed in the measurement electrode. The matrix compensation method is used to compensate for and eliminate the influence of interfering ions. This electrode can effectively compensate for interference and can be directly used in the aeration tank of sewage to measure the concentration of ammonia nitrogen.

    Technical Parameter

    model

    AmmoLyt Plus 700IQ

    VARiON Plus 700IQ

    NitraLyt Plus 700IQ

    VARiON Plus 700IQ

    Measurement parameters

    Ammonia nitrogen measurementmeasure

    Nitrate nitrogen measurementmeasure

    measuring principle

    useReference electrode and ion selectionElectrode for potential measurement;Built in microprocessor, two core shielded cable containing power and data transmission

    Ionic electrode:

    REFERENCE ELECTRODE

    working electrode

    Compensation electrode

    VARiON® PlusRef

    VARiON® PlusNH4

    VARiON® PlusK

    VARiON® PlusRef

    VARiON® PlusNO3

    VARiON® PlusCl

    Test range/resolution

    NH4-N: 1…1000mg/l / 1mg/l

    0.1…100mg/l / 0.1mg/l

    NH4+: 1…1290mg/l / 1mg/l

    0.1…129.0mg/l / 0.1mg/l

    K+: 1…1000mg/l / 1mg/l

    NO3-N1…1000mg/l / 1mg/l

    0.1…100mg/l / 0.1mg/l

    NO3-5…4500mg/l / 1mg/l

    0.5…450.0mg/l / 0.1mg/l

    Cl-: 1…1000mg/l / 1mg/l

    Main interferents

    Potassium ion:0-1000mg/l K+

    Chloride ion:0-1000mg/l Cl-

    Compensation method

    Automatic (installation of corresponding ion electrodes) or manual compensation

    Automatic (installation of corresponding ion electrodes) or manual compensation

    Temperature test

    built-inNTCtemperature probe
    Range:0…+40
    accuracy:±0.5K
    t95<20second

    temperature compensation

    automatic compensation0…+40

    Correction method

    Standard liquid2Point calibration or on-site actual water sample calibration(in common use)

    Surrounding conditions

    Operating temperature:0…+40Storage temperature:0…+40

    pHrange

    pH 4 …pH 8.5

    pH 4 …pH 11

    accuracy

    ±5%Test value or±0.2 mg/lStandard liquid

    working life

    18Month(Data obtained from testing in a sewage treatment plant environment)

    Mechanical Construction

    Protective cap:POM

    Electrode body and temperature probe:V4Astainless steel1.4571

    Electrode connector:POMProtection level:IP 68

    Maximum pressure

    0.2bar(includingSACIQElectrode wiring cable; After installing the electrodes)

    Insertion depth

    minimum30mm, the largest2m

    power consumption

    0.2W