The Nikos microwave radiation protective clothing shielding effectiveness testing system is used for GB 23463-2025 microwave radiation protective clothing clothing shielding effectiveness testing, supporting the collection and SE calculation of electric field strength at measurement points such as the head, chest, and lower abdomen of the human body model.

Product Details

Product Overview

Nikos Microwave Radiation Protective Clothing Shielding Efficiency Testing SystemTargeting the shielding effectiveness test of ready to wear clothing in GB 23463-2025 "Protective Clothing for Microwave Radiation Protection". The system is located in a shielded room and compares the electric field strength E0/E1 between the non wearing and wearing protective clothing using a microwave signal source, transmitting antenna, RF cable, receiving end, and human body model. The shielding effectiveness is calculated based on SE=20lg (E0/E1).

This system is suitable for reflective microwave radiation protective clothing, as well as absorbing microwave radiation protective clothing that uses absorbing materials to attenuate microwave radiation. Standardized testing configurations can be carried out around the shielding effectiveness of ready to wear clothing, testing frequency points, testing locations, environmental conditions, data recording, and reporting fields.

Applicable standard

  • GB 23463-2025 "Protective Clothing - Microwave Radiation Protective Clothing"

  • GB/T 12190-2021 "Measurement Method for Shielding Efficiency of Electromagnetic Shielding Rooms"

test project

  • Testing the shielding effectiveness of microwave radiation protective clothing for finished garments

  • Measurement of electric field strength E0 without wearing protective clothing

  • Measurement of electric field strength E1 after wearing protective clothing

  • Calculation of shielding effectiveness SE and determination of protection level

  • Full body shielding one-piece protective suit head, chest, and lower abdomen measurement point testing

  • Measurement points for chest and lower abdomen of split shielding protective clothing

  • Partial shielding protective clothing chest or lower abdominal measurement point test

Technical specifications

Applicable frequency range 300 MHz~40 GHz
test environment Temperature 15 ℃~30 ℃, relative humidity<80%
Test site Shielded room, performance meets the requirements of 5.8 in GB/T 12190-2021
Composition of the transmitting end Signal generator, transmitting antenna, and RF cable
Composition of receiving end Signal receiver, field strength probe or receiving antenna, and RF cable
Dynamic range of testing system Not less than 5 dB of the expected electromagnetic shielding effectiveness of the tested sample
Maximum allowable error of signal source frequency ±1×10^-3
Continuous wave signal level range -50 dBm~0 dBm
RF port voltage standing wave ratio ≤1.5
Field strength measurement range 0.5 V/m~800 V/m
Uniformity of field strength probe ±0.5 dB
Transmission antenna configuration 300 MHz~1 GHz logarithmic periodic antenna; 1 GHz~18 GHz, 18 GHz~26.5 GHz, 26.5 GHz~40 GHz horn antenna
Human body model size (1.7±0.15)m
Surface area of human body model (1.7±0.3)m²
Test partition Head, chest, lower abdomen
Human body model installation Fixed on the ground, convenient for wearing clothing
Reference specifications for shielded darkroom 8 m × 4 m × 3 m, can also be configured according to actual project conditions
power supply AC 220 V±30 V,50 Hz,1000 W

Protection level output

Protection level I 6≤SE<10 dB
Protection level II 10≤SE<20 dB
Protection level III 20≤SE<30 dB
Protection level IV 30≤SE<40 dB
Protection level V SE≥40 dB

System Composition

  • Shielded room or shielded semi anechoic chamber

  • Microwave signal source, power amplifier, transmitting antenna, and RF cable

  • Signal receiver, field strength probe or receiving antenna

  • Human body model and measurement layout for head, chest, and lower abdomen

  • Configuration of shielding doors, ventilation waveguide windows, power filters, and absorbing materials

Application scenarios

Nikos Microwave Radiation Protective Clothing Shielding Efficiency Testing SystemSuitable for testing institutions, quality inspection institutes, enterprises, and research institutes to establish GB 23463-2025 microwave radiation protection clothing shielding effectiveness testing capabilities, supporting the exchange of testing plans for full body shielding protective clothing, split body shielding protective clothing, local shielding protective clothing, and related mask products.

Consultation Focus

  • Before consultation, please confirm the type of test sample: full body shielding, split body shielding, or partial shielding protective clothing.

  • Can confirm the testing frequency range, number of measurement points, human body model configuration, and on-site conditions of the shielding room.

  • Can you confirm if sample information, equipment information, model specifications, environmental conditions are required in the report E0/E1、SE、 Fields such as protection level, date, and personnel.

  • Confirm the laboratory space, power supply, shielding room construction conditions, and subsequent installation and commissioning arrangements.