I. Overview
The EDX-N9 energy dispersive X-ray fluorescence spectrometer (EDXRF) is a physical element analysis method with special technical advantages such as fast, non-destructive sample analysis, simultaneous analysis of multiple elements, and low analysis cost. It is widely used in industries such as electronics, electronics, jewelry, toys, clothing, leather, food, building materials, metallurgy, geology, plastics, petroleum, chemical, and pharmaceuticals.
2、 What can EDX-N9 do?
① Rapid detection of hazardous elements restricted by the RoHS directive: lead Pb \ \ mercury Hg \ \ cadmium Cd \ \ total chromium Cr \ \ total bromine Br (PBB \ \ PBDE);
② Halogen instruction limits rapid detection of halogens: chloroCl \ bromoBr;
③ The 8 major heavy metal tests limited to industries such as toys, clothing, leather, etc.: cadmium (Cb), lead (Pb), mercury (Hg), chromium (Cr), antimony (Sb), arsenic (As), barium (Ba), selenium (Se);
④ Alloy composition analysis (stainless steel/copper, etc.); (Extended Functions)
⑤ Thickness detection of electroplating coatings (rapid detection of common coating thicknesses for copper nickel plating, copper tin plating, copper silver plating, copper gold plating, and copper nickel plating); (Extended Functions)
3、 The limiting standards for each element of the RoHS directive

4、 Instrument advantages
1. Integrated machine design
Integrated model design, integrating industrial computer and external 23.8-inch monitor, without the need for separate computer and monitor.
2. Independent module design
The independent module design of core accessories avoids mutual electromagnetic interference, improves the detection limit of the instrument, and reduces the failure rate of the instrument.
3. Reduce operating costs and minimize daily maintenance
① Adopting detectors that do not require liquid nitrogen cooling significantly reduces operating costs.
② Automatic aging function of X-ray tube: The aging of the X-ray tube is carried out to extend its service life. When the equipment is not running for a long time and restarted, the X-ray tube needs to be aged. The equipment can automatically perform aging to prevent faults from occurring.
4. High definition camera
Using a 1200W real pixel camera, the sample observation is clear and the positioning is accurate.
5. Limit standard settings
Customers can set different restriction standards according to supplier requirements.
6. Report format
Customizable test report output formats (Excel, PDF, Excel lists, etc.) to meet various statistical needs of enterprises.
5、 Technical specifications
|
Technical Specifications | |
|
z Element detection range: from sulfur (S) No.16 to uranium (U) No.92 on the periodic table
z Measurable sample types: liquid, solid, powder (any material can be detected)
z Test range: 2ppm-100%
z Detection limit: ≤ 2ppm
z Test time: 30-300S (automatic adjustment) | |
|
detector | |
|
|
z Origin: Amptek Corporation, USA
z Detector type: SIPIN
z Refrigeration method: electric refrigeration (non liquid nitrogen refrigeration)
z Resolution: 130EV ± 5EV (the smaller the value, the higher the resolution)
z Function: Detect sample characteristic X-rays, process the collected signals, and transmit the processing results to the computer.
z Type: American AMPTEK detector (detection system includes digital multi-channel pulse processor DPP, signal-to-noise ratio enhancer PA) |
|
X-ray tube | |
|
|
z Target material: Molybdenum target Mo
z Voltage: 0-50KV
z Maximum current: 1Ma
z Maximum power: 50W
z Function: Generate X-rays to excite the sample, causing each element in the excited sample to emit secondary X-rays. |
|
high voltage power supply | |
|
|
z Output voltage: 0-50KV; maximum current: 1mA; power: 50W
z Voltage regulation rate: 0.01% (from no-load to full load)
z Current regulation rate: 0.01% (from no-load to full load)
z Stability: ≤ 0.05%
z Function: Provide stable high voltage for X-ray tubes. |
|
Sample cavity | |
|
z Sample cavity size: 300mm Х 300mm Х 100mm
z Image: Ultra high definition CCD camera
z Sample bearing: fixed platform | |
|
Collimation filter system | |
|
z Collimator size: 0.8mm, 1mm, 3mm, 5mm
z Filter system: 8 composite material combination systems | |
|
data processing | |
|
|
z Built in industrial control computer: quad core i5 industrial control computer
z Windows 10 system
z External monitor
z External color inkjet printer |
|
Electrical parameters | |
|
z Input voltage: 220V ± 10V; 50Hz
z Rated power: 300W
z Noise: 50dB | |
|
dimensional parameters | |
|
z Instrument size: 450mm Х 400mm Х 300mm
z Weight: 38kg | |
|
Environmental Requirements | |
|
z Temperature: 15-35 ℃; Humidity:<85%
z Carrying platform: ordinary tables and chairs | |
|
Radiation protection standards | |
|
zNational standard GB18871-2002 GBZ115-2002 | |