Welcome Customer !

Membership

Help

Xindian Instrument (Hangzhou) Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Xindian Instrument (Hangzhou) Co., Ltd

  • E-mail

  • Phone

  • Address

    Room 301, Building 1, No. 105 Jucai Road, Changhe Street, Binjiang District, Hangzhou City

Contact Now

Coating thickness gauge

NegotiableUpdate on 05/07
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The EDX-A7 coating thickness gauge is a popular model specifically designed for analyzing coatings and Dacromet coatings on materials such as metal alloys, aluminum profiles, and plastics. It can be used for blind testing (i.e., without the need for standard sample calibration), allowing for testing of coating film thickness and analysis of substrate composition on customer samples, reducing the cost of purchasing standard samples (especially special samples). The carefully designed open working curve function is particularly suitable for process control of factory coatings and coatings on complex materials.

Product Details

The EDX-A7 coating thickness gauge is a popular model specifically designed for analyzing coatings and Dacromet coatings on materials such as metal alloys, aluminum profiles, and plastics. It can be used for blind testing (i.e., without the need for standard sample calibration), allowing for testing of coating film thickness and analysis of substrate composition on customer samples, reducing the cost of purchasing standard samples (especially special samples). The carefully designed open working curve function is particularly suitable for process control of factory coatings and coatings on complex materials.
Characteristics of EDX-A7 Coating Thickness Gauge:
1. Basic parameter analysis software, which can accurately test the coating film thickness of the sample without the need for standard sample calibration
2. The software can automatically set the power of the light tube based on the material, shape, and size of the sample, which can extend the service life of the light tube and fully utilize the performance of the detector, greatly improving measurement accuracy
3. Provide an open working curve calibration platform that can tailor the best coating analysis working curve for each user
4. Fine tune the sample design externally to reduce and prevent inaccurate testing caused by vibration caused by closing the sample cover after the sample is placed, resulting in changes in the testing position
7. Test report output formats (Excel, PDF, etc.) can be customized according to user requirements, meeting various statistical and formatting requirements of the factory
8. The software has the function of statistical analysis of multiple test results
To ensure the accuracy of the coating thickness gauge EDX-A7 and extend its service life, users need to pay attention to the following key points during use:
1、 Maintain the surface condition of the specimen
Cleaning: Before measurement, ensure that the surface of the specimen is clean and free of impurities such as oil and dust, as the coating thickness gauge is sensitive to the surface state of the specimen and impurities may affect the measurement results.
Flatness: The surface of the specimen should be kept flat to avoid unevenness or scratches, in order to reduce measurement errors.
2、 Correctly operate the instrument
Calibration: Before each use, the calibration operation should be carried out according to the instrument manual to ensure the accuracy of the measurement results. Regular calibration is also necessary to maintain the long-term stability of the instrument.
Measurement posture: During measurement, the measuring head of the coating thickness gauge should be kept perpendicular to the surface of the specimen and a constant pressure should be applied to avoid affecting the measurement data.
Environmental control: When using a coating thickness gauge, it should be operated in an environment with a temperature of 20 ± 5 ℃, humidity below 70%, and a stable power supply voltage of 220V ± 5V as much as possible to reduce the influence of environmental factors on the measurement results.
3、 Scientific Sampling and Data Processing
Sampling measurement: For specimens of different locations and areas, multiple measurements should be taken, and the average value should be taken as the final result to improve the reliability of the measurement.
Data processing: Record the data of each measurement and conduct comparative analysis to determine the accuracy and stability of the measurement results.
4、 Maintenance and upkeep
Cleaning and maintenance: After use, the coating thickness gauge should be cleaned in a timely manner to avoid impurities such as oil and dust adhering to the instrument. When cleaning, soft fabrics and neutral cleaning agents should be used to avoid damaging the coating and plating on the surface of the instrument with strong acidic and alkaline cleaning agents.
Battery replacement: Regularly replace the battery to avoid affecting the measurement results due to insufficient battery power. It is generally recommended to replace the battery after every 3 months or 5 measurements.
Storage environment: Coating thickness gauges that are not frequently used should be stored in a dry and ventilated environment, avoiding contact with the surface of the instrument through ventilation openings and dust accumulation areas.
Professional maintenance: Regularly invite manufacturers to arrange professional engineers to conduct annual inspections and maintenance of instruments to ensure their normal operation and accuracy.
5、 Precautions
Probe selection: For measurements of different types of coatings, a probe suitable for the coating should be selected to ensure the accuracy of the measurement results.
Avoid touching core components: Do not touch core components such as detector beryllium windows out of curiosity, as this may damage the instrument structure and affect measurement accuracy.
Follow operating procedures: When performing measurement tasks, it is necessary to strictly follow the operating instructions and relevant specifications to avoid improper operation that may cause damage to the instrument or distortion of measurement results.
In summary, by paying attention to the above key points, users can ensure that the coating thickness gauge EDX-A7 maintains high accuracy and long-term stability during use.