Naichi TG 309 Libra Supreme Thermogravimetric Analyzer
TGA basic functions
lManual or automatic annotation of weightlessness steps, units % or mg
lQuality time/temperature labeling residual quality labeling
lAnnotate the extrapolation starting and ending points of weightlessness steps
lPerform first-order differentiation (DTG) and second-order differentiation on the thermogravimetric curve, and annotate the peak temperature
lAutomatic baseline deduction
lc_DTA ® Function: DTA curve can be obtained simultaneously during thermogravimetric testing and can be used for temperature correction. (Optional)
lSuper-Res ® (Super resolution function): Automatic rate control for weight loss, automatic separation of adjacent steps (optional)
lTemperature modulation TGA function (optional)
Product Technical Parameters
lTemperature range: RT (10)... 1100 ° C
lScale range: 2g
lCooling rate:<10 minutes (1100 ° C... RT, He)
lVacuum sealing degree:<<10e-1 mbar
lc-DTA ® Function: Standard
l4-way mass flow controller: standard configuration
lHeating rate: 0 .. 200 K/min
lBalance resolution: 10 ng
lTemperature accuracy: ± 0.15 K
lAutomatic sampler: optional, 192+12 sample grades
lAutomatic vacuum and filling device: standard configuration
lColor touch screen display: standard configuration
Naichi TG 309 Libra Supreme Thermogravimetric AnalyzerRich accessory selection
constant temperature water bath
Equipped with a constant temperature water bath with a refrigeration system, its functions are twofold: firstly, to keep the weighing system in a stable constant temperature working environment, unaffected by heat transfer from the furnace body at high temperatures, and to reduce system drift during long-term testing; secondly, to quickly cool the furnace body, and also to start testing at temperatures lower than room temperature as needed.
vacuum pump
The instrument can be equipped with a vacuum pump.
Sample holder
The instrument can be equipped with conventional brackets, highly corrosion-resistant brackets, and high sensitivity c-DTA ® Three different types of sample brackets are available, suitable for different sample situations and testing needs.
crucible
The instrument provides a variety of crucibles with different textures and sizes to meet the needs of experiments, including alumina crucibles, platinum rhodium crucibles, aluminum crucibles, graphite and quartz crucibles, etc
Calibration standard sample
The instrument provides a series of temperature calibration standard samples, covering The testing temperature range is from 10 ° C to 1100 ° C. These standard calibration materials are suitable for testing in accordance with ASTM and CEI-IEC standards.
Automatic sampling system ASC
Can be equipped with an automatic sampling system ASC, It can automatically and effectively conduct routine testing to meet the needs of quality control and research and development. Testing does not require the presence of experimenters and can be conducted day and night, even on weekends, allowing the instrument to be fully utilized.