DSC 300 Caliris® Classic differential scanning calorimeter

NegotiableUpdate on 01/17
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
As a basic DSC, it is impeccable: it includes all the basic DSC functions, can meet the vast majority of routine testing needs, and has excellent performance. It can also be equipped with multiple expansion modules.
Product Details

DSC 300 Caliris ® Classic differential scanning calorimeterAs a basic modelDSC, It is impeccable: it includes all the basic DSC functions, can meet the vast majority of routine testing needs, and has excellent performance. It can also be equipped with multiple expansion modules.

Basic functions of DSC

Determination of heat absorption/Exothermic behavior: The starting point, peak value, inflection point, and termination point temperatures can be determined, and automatic peak search can be performed.

peak area/Enthalpy calculation: Multiple types of baselines can be selected for partial area analysis.

Comprehensive analysis of peaks: Various information such as temperature, area, peak height, and peak width can be obtained simultaneously in one annotation. Crystallinity calculation.

Comprehensive glass transition analysis.

Automatic baseline deduction.

Specific heat testing and analysis.

BeFlat ®: Use polynomial fitting to fit and subtract baselines at different heating rates.

Tau-R mode: By incorporating the time constant and thermal resistance factors of the instrument into the calculation and subtracting them, sharper DSC peaks can be obtained.

TM-DSC (temperature modulated DSC, optional): It can separate reversible heat flux (thermodynamic) and irreversible heat flux (kinetic) effects from the total heat flux curve.

Another one that meets the requirementsSpecial software features for GLP, GMP, 21CFR and other standards.

DSC 300 Caliris ® Classic Differential Scanning Calorimeter Product Technical Parameters

temperature range: -170°C . .. 600°C

temperature accuracy: ± 0.1 K (In)

Refrigeration system optionsCompressed air cooling (RT... 600 ° C); IC40 (-40 ° C... 600 ° C); IC70 (-70°C ... 600°C) ; LN2 cooling, automatic control (-170 ° C... 600 ° C)

heat/Cooling rate: 0.001 K/min... 100 K/min

Enthalpy accuracy: ± 0.1% (In)

atmosphereInert (static, dynamic), oxidation

Gas controlThree gas switches; 3-channel mass flow meter, optional

ASC: 20 samples and reference positions, optional