N2000 Chromatography Workstation Upgraded Serial Version

NegotiableUpdate on 01/03
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The upgraded serial version of N2000 chromatography workstation is provided by Shenzhen Yixin Instrument Equipment Co., Ltd. It is based on the traditional N2000 and combined with the new survey software to solve the incompatibility problem of the old N2000 in 64 bit systems.
Product Details

N2000 Chromatography Workstation Upgraded Serial Version


N2000 Chromatography Workstation Upgraded Serial Version
It is provided by Shenzhen Yixin Instrument Equipment Co., Ltd. It is a modified version of the traditional N2000 combined with new survey software, which solves the incompatibility problem of the old N2000 in 64 bit systems.

1Chromatography workstationUpgrade serial version software parameters:

1. It can automatically identify negative peaks.

2. Automatically adjust the integration peak width during the analysis process.

3. Automatic baseline tracking and automatic classification of chromatographic peak types; Peak rise and fall points.

4. Powerful manual integration function, peak addition and subtraction, peak baseline adjustment, and cutting method adjustment.

5. Integral sensitivity of 1 microvolt · s, Min resolution of 1 microvolt, Min peak width of 0.1 seconds.

6. The software can export AIA.CDF spectra for the analysis of traditional Chinese medicine fingerprint spectra.

7. Data reanalysis function, archiving.

8. Quantitative calculation methods: normalization method, internal standard method, external standard method.

2、 Features of upgrading the serial version of the chromatography workstation:

1. Add three-level permission management, where users have independent usernames and login passwords

2. It has installation authentication function, which can check whether the software installation is complete

When configuring, the hardware connection is judged by the signal light to determine the connection status, which is relatively fast

4. Sampling frequency is 40Hz, resulting in better spectral smoothness and more accurate integration

5. Signal value units can be customized according to requirements

6. System logs can be searched and printed by time and operation content classification

7. Calculation formulas can be designed according to Chinese, American, European, Japanese, and four custom standards

8. Supports XP, Win7, Win8, Win10 32-bit, 64 bit operating systems

9. The calibration curve has been considered, and there are three options to choose from: passing through and ignoring the origin

10. The triggering method provides three options: start only, start start, and start stop

11. Summary can automatically calculate relative deviation