To ensure that V-2000 and V-3000 are new programs, the CHEMetrics website will update the photometer program, which only takes a few minutes to upload and is easy to operate. The optional PowerLab station updates the handheld V-3000 series to provide a complete laboratory solution in one instrument.
The V-3000 is easy to carry, easy to operate, sturdy and waterproof, capable of reading concentration, absorbance and transmittance percentages. This multifunctional instrument can store up to 100 data points, including date/time tags that can be downloaded to a computer.
| parameter | V-3000 photometer | V-2000 photometer |
| Instrument Applicability | Portable/Desktop | portable |
| screen | Display/Backlit | Liquid Crystal Display (LCD) |
| Control automatic shutdown | YES | NO |
| power supply | battery Rechargeable battery* Universal cable/plug* | battery |
| Test wavelength | 436, 517, 557, 594, 610, 690 | 420, 520, 580, 610 |
| Data interface software | YES | NO |
| Test bottle size | 13mm, 28mm | 13mm, 16mm |
| Language Selection | Yes, Chinese, German, French, Spanish | NO |
| Web update method | You can download the update method from the website | You can download the update method from the website |
| water resistance | IP67 | IP67 |
| Operating Temperature | 0 to 50 ℃ | 0 to 45 ℃ |
| data recording | 100 points | 100 points |
CHEMetrics V-0002 Verification Kit, used to check CHEMetrics ®V-2000Multi parameter water quality analyzerperformance
Optional accessories for V-2000
A-0182 portable bag
A-0307 RS232 to USB adapter (for V-2000 and V-3000)
V-0002 V-2000 Verification Kit
I-5543 Hydrogen Peroxide Verification Kit
Preparation for operation of multi parameter water quality analyzer
1. Ensure that the instrument is in a stable environmental condition
Avoid direct sunlight, strong electromagnetic interference, and high humidity that may affect the test results.
Ensure that the instrument is placed on a stable workbench, avoiding vibration and impact.
2. Check the required power specifications for the instrument
Confirm the power requirements (such as voltage, current, etc.) according to the instruction manual.
Connect the instrument to a stable power supply, ensuring a stable power connection to prevent voltage fluctuations from damaging the instrument.
3. Prepare corresponding water sample collection containers and reagents
According to the testing requirements, prepare the corresponding water sample collection containers and reagents.
Ensure that the samples have been collected and stored correctly to avoid contamination or spoilage.
Startup and Calibration of Multi Parameter Water Quality Analyzer
1. Press the power switch
Press the power switch and wait for the instrument to start. The startup time is usually around 1 minute.
Calibration can be performed once the instrument displays normally.
2. Enter calibration mode
Select the parameters that need to be calibrated on the screen and follow the prompts to perform the calibration operation.
Standard solutions should be used for calibration to ensure the accuracy of test results.
Adjust the measurement range of the instrument as needed to make it suitable for the actual situation of the test sample.
Water sample testing
1. Take a certain amount of water sample
Take a certain amount of water sample and pour it into the prepared water sample collection container.
Ensure that the sample fully covers the sensor and wait for the display of the measurement results.
2. Insert the water sample collection container into the position of the instrument
Insert the water sample collection container into the position of the instrument to ensure a good connection.
Check if the sensors and probes are clean and insert them into the test sample.
3. Select the parameters to be tested on the instrument operation interface
When the instrument is turned on, select the water quality parameters that need to be monitored through the menu interface.
Use the directional keys to move the cursor and the confirm key to select parameters.
After selecting the target parameters, press the confirm button and the instrument will start automatic measurement.
During the measurement process, the instrument will display real-time data. After the measurement is completed, the instrument will automatically save the data.
Data Processing and Storage
1. Read data
During the measurement process, you can read the current transmittance or absorbance value of the sample from the instrument's display at any time.
If further processing or analysis of the data is required, software equipped with the instrument or external data processing tools can be used.
2. Store data
If it is necessary to save measurement data for subsequent analysis or reference, the data storage function of the instrument can be used.
Please refer to the instrument's user manual or consult relevant technical personnel for specific operating methods.