K-4518 Ethylene Glycol Test Box

NegotiableUpdate on 02/02
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
K-4518 Ethylene Glycol Test Kit: Ethylene glycol and propylene glycol are the main components of commercial antifreeze, and they are used together with various corrosion inhibitors to protect metal surfaces in cooling water systems. The $r $nCHEMetrics ethylene glycol testing kit uses a chemical method developed by CHEMetrics to monitor drinking water pollution caused by ethylene glycol in cooling systems. This tool is also used to detect ethylene glycol in storm wastewater and monitor the circulation of ethylene glycol.
Product Details

K-4518 Ethylene Glycol Test BoxColorimetric testing kit

scope MDL method Catalog Number Supplement product number
1-15ppm ethylene glycol; 10-300 ppm propylene glycol 1 ppm Purpald-Periodate K-4815 R-4815

K-4518 Ethylene Glycol Test Boxmethod

Ethylene glycol and propylene glycol are the main components of commercial antifreeze, which are used together with various corrosion inhibitors to protect metal surfaces in cooling water systems.

The CHEMetrics ethylene glycol testing kit uses chemical methods developed by CHEMetrics to monitor drinking water pollution caused by ethylene glycol in cooling systems. This tool is also used to detect ethylene glycol in storm wastewater and monitor the circulation of ethylene glycol.

Purpald-Periodate 法

Reference: Purpald developed by Aldrich Chemical Company ® - The periodate method, Fritz, James S. and Schenk, George H., Mass Chemical Analysis, 4th edition, p. 277 (1979).

In colorimetric method, periodic acid oxidizes ethylene glycol and propylene glycol to formaldehyde, which then reacts with Purpald in alkaline solution. The measurement results obtained by visual and instrumental methods are expressed in ppm ethylene glycol or propylene glycol. All measurement tools come with a conversion factor, which is used to convert the measurement results into results in units of ethylene glycol. This testing method requires less operation time than the standard colorimetric acid analysis method. Shelf life: 5 months, we recommend using within 4 months for quality preservation.