- Phone
-
Address
Ruixiang Road West Section, Xuchang Economic Development Zone, China
Xu Changrui Taifeng Technology Co., Ltd
Ruixiang Road West Section, Xuchang Economic Development Zone, China
Multi functional glass continuous distillation experimental device
Multi functional glass continuous distillation experimental deviceMain functions
1Familiar with the structure, process, and structural functions of each component of the distillation tower;masterCorrect operation of distillation towerLearn the method for determining the theoretical number of plates in packed distillation columns;
2Master the principle of distillation,Understand the influencing factors of distillation operations and master the purification and preparation methods of high-purity substances;understandreactionrectificationExtraction distillationConventional distillationbetweenDifference, MasteryDifferent distillation methodsSuitable systemAnd process;Understand the difference between vacuum distillation and atmospheric distillation, and master the applicable process ranges for the two different operating conditions;
3Conduct experiments on conventional distillation, reactive distillation, extraction distillation, azeotropic distillation, etc. under normal or reduced pressure;
4Master the composition of computer automatic control systems, understand the roles, interactions, and relationships of various components;
5Mastering QiphasechromatographyHow to use the Abbe refractometerLearn to learnAnalyze product composition.
Multi functional glass continuous distillation experimental deviceDevice features
deviceincludecontinuousThe distillation tower and intermittent distillation tower are two parts, with the two towers operating independently. Double glass distillation tower,The entire tower is made of visible transparent glass material, which allows for clear observation of the gas-liquid flow inside the tower.The outer wall of the tower is made of transparent conductive film using new insulation technology, and electrically heated insulation is used to offset heat loss. There is also a glass sleeve covering the exterior of the tower for insulation.Two metering pumps feed the continuous distillation tower.Automatic temperature control of tower kettle, digital display of instruments; Two sections of the tower are manually insulated. Temperature measurement of tower top kettle, instrument digital display. Reflux ratio self-control, instrument digital display.
Computer data acquisition interface and software, using high-precision process control instruments and data control and acquisition configuration software for high reliability and small sizeAIDCSDistributed Control System (Instrumentation)+serial communication+In the upper monitoring computer mode, connect to the computer for remote control and display.Real time display and monitoring of process flow and process parameters, canControl and collect data such as temperature and reflux ratio.Implement data collection, processing, and analysisHistorical data query and export; Alarm settings, queries, and records.
Multi functional glass continuous distillation experimental deviceMain Configuration
Continuous distillation tower, intermittent distillation tower, multi mouth glass ball kettle, tower top condenser, oil-water phase separation tower top condenser, dual liquid feeding pump, collection bottleReflux control systemTemperature sensors, flow meters, electric heating packs, racks, instrument distribution cabinets, vacuum systems, computer data acquisition and control software, etc.
technical indicators
1Operating pressure: normal pressure or absolute pressure10 mmHgOperating temperature:RT~200℃;
2Processing method: continuous or intermittent distillation;
3Tower top extraction system: reflux ratio controller automatically controls the extraction and reflux ratio;
4Continuous distillation tower body: made of glass, tower diameterΦ20mm, height1.4m,5Side mouth, two sections (upper and lower) of the tower outer wall are heated and insulated with conductive film, with heating power for each section300WManual control; Tower body insulation cover material glass, diameter~Φ70mm, height~1.4m,5Side mouth; Loading Φ2×2mm 316Lstainless steelθMesh ring packing;
5Intermittent distillation tower body: made of glass, tower diameterΦ20mm, height1.2mWithout side openings, a section of conductive film on the outer wall of the tower is used for heating and insulation, with heating power300WManual control; Tower body insulation cover material glass, diameter~Φ70mm, height~1.2m, without a side opening; Loading Φ2×2mm 316Lstainless steelθMesh ring packing;
6Tower top condenser: made of glass, snake tube condenser, external reflux, oil-water phase separator structure;
7Tower top condenser: made of glass, snake tube condenser, external reflux, pendulum type;
8Tower kettle: made of glass, multi mouth spherical, with a capacity of~500mlEquipped with interfaces for temperature measurement, pressure measurement, feeding, and distillation tower,2One;
9Dual preheaters, made of glass material, electrically heated;
10Electric heating package:500mlElectric heating, automatic temperature control,2One;
11Collection bottle: made of glass, capacity100~150ml, with glass stopcock;
12UType pressure gauge: made of glass material,2One;
13Feed pump:Liquid feeding pump,2platformRotary flowmeter,0.6~6ml/minEquipped with a regulating valve;
14Lifting platform:200*200mmStainless steel, used to adjust the height of the tower kettle,2One;
15Reflux ratio controller: Reflux ratio1~99:99~1Adjustable in seconds,2Set;
16Temperature display instrument: Temperature measurement points are set at the top and bottom of the tower,Intelligent display instrumentAI701,Digital instruments,0.2Grade accuracy,On demand configuration;
17Temperature control instruments: Preheaters and tower kettles are equipped with temperature control points for automatic temperature control,intelligencetemperature controlinstrumentAI518,Digital instruments,0.25Grade accuracy,On demand configuration;
18Temperature sensor: thermocouple,EType, temperature measurement and control points can be configured as needed;
19Vacuum system: including vacuum pump, buffer tank, valve, pressure gauge, etc,1Set;
20Configure pipelines, fittings, valves, aluminum sleeves, gaskets, and joints as needed;
21Control cabinet and rack: integrated control cabinet (including electrical components), electrostatic spraying rack, with movable brake wheels that can be moved or braked; All operations can be performed directly in the control cabinet.
22Computer data acquisition and control software.