- Phone
-
Address
Ruixiang Road West Section, Xuchang Economic Development Zone, China
Xu Changrui Taifeng Technology Co., Ltd
Ruixiang Road West Section, Xuchang Economic Development Zone, China
Experimental apparatus for measuring gas-liquid equilibrium data
Experimental apparatus for measuring gas-liquid equilibrium dataMain functions:
This device is a specialized teaching equipment for laboratory chemical engineering. The main body of the device is a small equilibrium kettle with gas-liquid double equilibrium. Its advantages include easy operation, short equilibrium time, low sample consumption, accurate measurement data, no liquid droplets carried by the vapor, and no backmixing or boiling of the liquid. It is an ideal experimental instrument. It is suitable for scientific research data determination under normal pressure.
Experimental apparatus for measuring gas-liquid equilibrium dataDevice Introduction:
Gas liquid equilibrium data is extremely important for distillation, absorption, and other processes in chemical unit operations. In the design of distillation columns, it is the most fundamental data, and many special binary systems often lack such data, which brings difficulties to the design. Accurate data can be obtained through self measurement. Therefore, it is meaningful to master the method for determining the vapor-liquid equilibrium data of simple binary solutions.
Experimental apparatus for measuring gas-liquid equilibrium dataMain technical indicators:
(1)Glass equilibrium kettle: Solution volume:20-30 mlHeating power of heating rod:100 W;
(2)Temperature control: automatic temperature control, usingAIIntelligent instrument, precisionFS≤0.25%Number display.
(3)Operating temperature:150℃, operating pressure: atmospheric pressure.
Device configuration:
(1)Balance kettle: Material: Glass, Solution volume:20~30mlThere are sampling ports for both gas and liquid phases1The sampling port is sealed with an aluminum sleeve and sealing gasket, and equipped with a vacuum insulation jacket;
(2)Condenser: spherical glass condenser with external cooling water jacket, connected to the balance kettle through a conical grinding port connection
(3)Electric heating rod: Power:100WMaterial: stainless steel, equipped with aviation plug, easy to disassemble and replace
(4)Temperature sensor:EType armored thermocouple, Ф1~1.5mm, Long300mm,2branch
(5)Temperature control instrument:AI-518Digital instrument, control accuracy ±0.25%
(6)Temperature measuring instrument:AI-701Digital instrument, control accuracy ±0.25%
(7)Ammeter:0~1A;
(8)Precision thermometer:0-50℃,50-100℃,100-150℃ each1branch
(9)Sampler: Gas phase sampler, liquid sampler each5branch