1、 General instructions for DC power calibrator
Krohn-HiteModel 526 DC power calibratorIt is a highly stable and repeatable DC voltage and current source that provides N.I.S.T. traceable voltage and current for use in production, calibration laboratories, quality assurance and control departments, design laboratories, or anywhere requiring accurate voltage and current sources.
526 provides a precise voltage of ± 100nVdc to ± 111.1110Vdc within 20ppm for 1 year, and a precise current of ± 10nA to ± 111.1110mA within 50ppm for 1 year. It has very low noise, with a measured noise of<12 μ Vrms over a bandwidth of 10Hz to 100kHz.
2、 Decimal control
The microprocessor used for decimal control allows continuous use of a decimal number, with the ability to carry and borrow from more important decimal numbers * for ease of use and convenient manual operation. By using a decimal control, monotonic linear A/D measurements can be achieved at any resolution.
3、 Display screen and front panel control
A user-friendly 2-line 40 character display screen and six front panel decimal switches, capable of * carry and borrow, allowing for fast and accurate voltage and current settings. You can use the decimal switch and range key on the front panel to modify the output settings. Output as 2-wire, 4-wire implemented through a button or GPIB/LAN. When necessary, the protection function places the output in safe mode. The 526 output can be set to 0V, allowing output detection to maintain true 4-wire low impedance output.
4、 Range and Resolution
526 provides four voltage ranges of 100mV, 1V, 10V, and 100V, with resolutions of 100nV, 1 μ V, 10 μ V, and 100 μ V, respectively. Provide two current ranges of 10mA and 100mA, with resolutions of 10nA and 100nA respectively.
5、 Non-volatile memory
Model 526 DC power calibratorProvides up to 32 storage output settings that can be called at any time.
6、 Voltage, current, and compliance limits
Select voltage and current limits to prevent users from damaging sensitive circuits or tested devices, which can be set from the front panel; Additionally, hardware compliance voltage limits of 120V, 36V, 26V, or 16V can be set.
7、 Application
The 526 DC power calibrator is highly suitable for various applications, such as the design, testing, and calibration of high-speed, high-resolution A/D converters; Design and certification of high-speed data recording and process control systems; Calibration of digital voltmeter and multimeter; As an "embedded standard" and/or simulator; Design, testing, simulation, and certification of thermocouples, strain gauges, and sensor instruments. It is also a substitute for the simulated Model 8200.
8DC power calibratorSpecifications
1. Voltage mode specifications
The specifications are suitable for 23 ℃± 1 ℃ and relative humidity<70%.



Temperature coefficient: 18 ℃ to 28 ℃, set ± 5ppm, range ± 1ppm/℃; Working limit, set at ± 10ppm, with a range of ± 2ppm/℃.
Stable time: 2ms for 100mV, 1V, and 10V ranges; 15ms for 100V ranges; 35ms for range changes.
Line specification: ± 2ppm set for 10% line fluctuation.
Load specification for 4-line operation: from no load to 100mA full load, set at<± 2ppm+1 μ V. Measurements must be taken at the connection point of the sensing lead to the load.
Noise and Ripple (rms):

2. Current mode specifications


Noise and Ripple (rms):

Temperature coefficient: 18 ℃ to 28 ℃, set ± 5ppm, range ± 1ppm/℃; Working limit, set at ± 10ppm, with a range of ± 2ppm/℃.
Peak output current: ± 110mA. The output is protected from damage by a current limiter.
Line specification: ± 2ppm set for 10% line fluctuation.
Compliance voltage effect: For changes in compliance voltage of 90V,<set ± 2ppm+1 μ V.
3. GPIB programming
Sub devices: SH1, AH1, T6, L4, SR1, RL0, PP1, DC0, DT0, E1.
Line termination: GPIB EOI signals are always sent along with the last character on the line.
Speaker function: Allow querying Model 526 through the controller.
Communication data rate: usually 3ms when there is no range change, and 35ms when there is range change.
4. Terminal
The output terminals are installed on the front and rear panels (the rear panel is equipped with a 6-pin Amphenol connector and accessories are provided). The front terminal has 5 channels, gold color, low heat, fixed at the center at the three-quarters "position, and can only use one set of terminals at a time. The front and rear terminal groups are configured with the following remote sensing outputs:
High output and high sensitivity
Low output and low sensitivity
Shell grounding
5. Operation mode
Local (LCL): Allow * front panel control
Call (RCL): Allow viewing and outputting of stored front panel settings from memory locations 01 to 32
Edit (EDT): allows editing of any memory location from 1 to 32
Remote (REM): Indicates that Model 526 is remotely controlled by IEEE-488 or LAN (optional)
6. Special functions
Port selection: Allow setting of IEEE-488 port or optional LAN port (if installed).
Menu selectable voltage and current limits: Allow setting voltage limits from 0V to 110V for each pole, and current limits from 0mA to 110mA for each pole. Fault safety hardware voltage clamp (compliant) limit: allows the hardware clamp voltage to be set in the current mode. The selection range is 120V, 36V, 26V, and 16V, ± 5%+± 1V.
Startup sequence: Allow the startup conditions to be set to factory default settings or last settings
Display area: Allow partial display of output voltage or * display
Zero crossing: Allow decimal control of voltage and current for zero crossing
Remote Protocol: Allow setting the remote programming protocol to Krohn Hite or Analogic 8200
7. Conventional
Power requirements: Line voltage, 105 to 130 or 210 to 260Vac, single-phase, 50Hz/60Hz, peak value of 60W.
Preheating time (from calibration temperature): 2 hours to rated accuracy
Display: 2 lines, 40 characters, LCD。 Display output settings and other related information.
Button key: membrane
Isolation: Power transformer to analog output, control logic to analog output, optoelectronic isolation, to chassis 100Vdc.
Protection: Voltage mode, short circuit and overload protection. Current mode, open circuit protection. Display message indication. Once overload is detected, protection is activated.
temperature
Working limit: 0 ℃ to 50 ℃
Calibration: 23 ℃± 1 ℃
Storage: -40 ℃ to 85 ℃
8. Safety
Model 526 is used for measurement, control, and laboratory purposes, and can meet the following standard requirements for electrical equipment safety: IEC61010-1, EN61010-1.
9. Electromagnetic compatibility
Radiation and immunity: EN61326-1, EMC, 61000-4-2; ESD, 61000-4-3; Radiation immunity, 61000-4-4; EFT, 61000-4-5; Surge, 61000-4-6; Conducted anti-interference, 61000-4-8; Magnetic field anti-interference, 61000-4-11; Voltage interruption EN61010-1. CE complies with Class B equipment.
10. Mechanical specifications
Size and weight: including foot height of 4 "(10.28cm), excluding foot height of 3.5" (9cm); Width 14.15 "(36.36cm); Depth 14.3 "(36.75cm); 12lbs (5.4kg) net weight, 14lbs (6.3kg) total weight.
11. General Information
Certification: Each new instrument will be issued a certificate of conformity to demonstrate the calibration and traceability of N.I.S.T.
Warranty: 1 year warranty for parts and labor, including specifications and performance.
12. Accessories
Output connector with clamp
United States, three terminal line
CD Operation Manual

13. Optional
Extended 1-year warranty: Part number EW526
LAN: LAN remotely controls Model 526 through computer
PCR100: Precision 100 Ω resistor

14. Optional accessories
RK-314: The rack installation kit allows the Model 526 to be installed into a 19 "rack space.

CAB-005: Cable, multi-layer double banana plug, with shielded balance wire.

CAB-018: Cable, multi-layer double banana plug.

CAB-023: Cable assembly, low heat EMF expandable banana head.

CAB-024: Cable group, low heat EMF shovel foot plug wire

CON13/15: 6-pin Amphenol output connector, provide fixture.

CASE-2720B: Portable protective case, black, lightweight HPX resin, waterproof, with extendable pull rod and pulley.

The manual is subject to change without prior notice.