Product Name: Mitsubishi Chemical AQUAMION Reagent Product Features: It can be used not only for Mitsubishi moisture meters CA-200, CA-31, KF-200, KF-31 in Japan, but also for Coulomb moisture meters produced by different companies.

Product Details

Product Name:Mitsubishi Chemical AQUARERNreagent
Product Features:AQUAMICRONThe reagent can not only be used for the Japanese Mitsubishi moisture analyzer CA-200,CA-31, In addition to using KF-200 and KF-31 instruments, they can also be used for Coulomb moisture meters produced by different companies.
The types of Mitsubishi Chemical reagents in Japan include:
(1)AQUAMICRON ® Series (applicable to Coulombic titration method)
(2)AQUAMICRON ® SS-Z Series (suitable for volumetric method, without pyridine and chlorine)
AQUAMICRONreagentDetailed information:
AQUAMICRONreagent
1、 Product Introduction:
Mitsubishi ChemicalAQUAMICRONreagentNot only can it be used for Mitsubishi moisture analyzer in JapanCA-200CA-31KF-200KF-31In addition to using the instrument, it can also be used for Coulomb moisture meters produced by different companies, with excellent performance and reputation
Mitsubishi Chemical reagents from Japan, including:
1AQUAMICRON® Series(Applicable to Coulombic titration method)
2AQUAMICRON® SS-Z Series(Suitable for volumetric method, without pyridine and chlorine)
3AQUAMICRON® SS Series(Suitable for volumetric method, containing pyridine)
4 Water standard solution.



1AQUAMICRON® Series(Applicable to Coulombic titration method)

model code packaging purpose specification main ingredients
AQUAMICRON ® AX Bottom XAMA 500mL [General purpose]
Organic solvents, inorganic compounds, oils, petroleum products, various gases, etc.
zuiHigh water content
0.15 mg H2O/mL
Methanol, propylene carbonate
AQUAMICRON ® AX01 XAMA01 100mL
AQUAMICRON ® AS ; SAMA 500mL [Used for oils]
Naphtha, gasoline, diesel, insulating oil, etc.
zuiHigh water content
0.15 mg H2O/mL
Methanol and chlorine
AQUAMICRON ® AKX AKX 500mL [Used for aldehydes and ketones]
Ketones, silicone oils, low carboxylic acids, etc
zuiHigh water content
0.15 mg H2O/mL
Acrylic carbonate, ethoxydiethylene glycol ether
AQUAMICRON® CXU CXU 5mL x10/box [Catholyte]
andAXTheASTheAKXuse together
zuiHigh water content
0.6 mg H2O/mL
methanol
AQUAMICRON® FLS FLS 500mL [Suitable for glass free electrolytic cells]
Organic solvents, inorganic gases, etc
zuiHigh water content
0.15 mg H2O/mL
Methanol, propylene carbonate

Product Features:
1 Ultra low environmental pollution: does not contain carbon tetrachloride, chlorine, etc
2 Wide application range: suitable for organic solvents, inorganic compounds, oils, and various gases
3 High quality and high performance: Performance in precise measurement and endpoint stability.
4 Easy to use: Can be used for the vast majority of Coulomb moisture meters on the market today

IIAQUAMICRON® SS-Z Series(Applicable to volumetric titration method, excluding pyridine and chlorine)

model number packaging purpose specification main ingredients
AQUAMICRON® Titrant SS-Z 1mg SSZ10M 500mL [General purpose]
Suitable for low moisture content samples
Titration volume
0.7-1.2
mg H2O/mL
Ethoxydiethylene glycol ether
AQUAMICRON® Titrant SS-Z 3mg SSZ30M 500mL [General purpose] Titration volume
2.5-3.5
mg H2O/mL
AQUAMICRON® Titrant SS-Z 5mg SSZ50M
*SSZ50L
500mL
1000mL
[General purpose]
Suitable for high moisture content samples
Titration volume
4.5-5.5
mg H2O/mL
AQUAMICRON® Solvent GEX GEX 500mL [General purpose]
Organic solvents, inorganic chemicals, agricultural chemistry, pharmaceutical products, fertilizers, cleaning agents, food, etc
zuiHigh water content
0.2 mg H2O/mL
methanol
AQUAMICRON® Solvent OLX OLX 500mL [Used for oil]
Liquid oils such as naphtha, gasoline, diesel, and insulating oil
zuiHigh water content
0.5 mg H2O/mL
ethanol
AQUAMICRON ® Solvent OLII OL2 500mL [Used for oils and fats]
Solid and paste like oils and fats such as naphtha, gasoline, diesel, heavy oil, insulating oil, and grease
zuiHigh water content
0.2 mg H2O/mL
Methanol and chlorine
AQUAMICRON® Solvent KTX KTX 500mL [Aldehydes and ketones are used]
Ketones, silicone oils, low carboxylic acids, aldehydes (excluding acetaldehyde)
zuiHigh water content
0.5 mg H2O/mL
Acrylic carbonate
Ethoxydiethylene glycol ether
AQUAMICRON ® Solvent SU SSU 500mL [Sugar use]
Carbohydrates, proteins, gelatin, additives, animal feed
zuiHigh water content
0.5 mg H2O/mL
Formamide, formaldehyde

IIIAQUAMICRON® SS Series(Suitable for volumetric titration method, containing pyridine)



model number packaging purpose specification main ingredients
AQUAMICRON® Titrant SS 1mg GKS10M 500mL [General purpose]
Suitable for samples with low moisture content
Titration volume
0.7-1.2
mg H2O/mL
Chlorine formula, pyridine
AQUAMICRON® Titrant SS 3mg GKS30M 500mL [General purpose] Titration volume
2.5-3.5
mg H2O/mL
AQUAMICRON® Titrant SS 10mg GKS100M 500mL [General purpose]
Suitable for samples with high moisture content
Titration volume
8-12
mg H2O/mL
AQUAMICRON ® Solvent ML GML 500mL [General purpose]
Organic solvents, inorganic compounds, agricultural chemistry, pharmaceuticals, fertilizers, cleaning products, food
zuiHigh water content
0.2 mg H2O/mL
methanol
AQUAMICRON® Solvent MS GMS 500mL Methanol, pyridine
AQUAMICRON® Solvent CM GCM 500mL [Used for oils]
Naphtha, gasoline, diesel, heavy oil, insulation oil, grease (solid, paste, butter)
zuiHigh water content
0.3 mg H2O/mL
Chlorine and methanol
AQUAMICRON® Solvent CP GCP 500mL [Ketones used]
Ketones, silicone oils, acetic acid and other low carboxylic acids
Aldehydes (excluding acetaldehyde)
zuiHigh water content
0.5 mg H2O/mL
Chlorine formula, propylene carbonate
AQUAMICRON ® Solvent PE GPE 500mL water content
0.2 mg H2O/mL
Pyridine, ethylene glycol
AQUAMICRON ® Solvent PP GPP 500mL [Aldehydes used]
Acetaldehyde, acetaldehyde, butyraldehyde, etc
water content
0.2 mg H2O/mL
Pyridine, propylene carbonate
AQUAMICRON® Solvent FM GFM 500mL [Sugar use]
Carbohydrates, proteins, gelatin, food additives, animal feed, etc
zuiHigh water content
0.2 mg H2O/mL
Formamide, methanol
AQUAMICRON ® Solvent ME GME 500mL [Used for vaporizer]
Gas samples, nitrogen for use
zuiHigh water content
0.2 mg H2O/mL
Methanol, ethylene glycol



4、 Water standard solution
Used for Coulombic titration method

model code packaging specification main ingredients purpose
AQUAMICRON® Water Standard 0.1
Water standard solution
5mLx10/box Titration volume
0.1±0.01 mg H2O/g
octanol Testing the accuracy of Coulomb titration method
AQUAMICRON® Water Standard 0.2 5mLx10/box Titration volume
0.2±0.01 mg H2O/g
Octanol (modified) Used to check the accuracy of Coulomb moisture analyzer
AQUAMICRON® Water Standard 1 5mLx10/box Titration volume
1±0.05 mg H2O/g
propylene carbonate Used to check the accuracy of Coulomb moisture analyzer
AQUAMICRON® Check Solution P GCHP 100mL water content
3.8 - 4.2 mg H2O/g
propylene carbonate The endpoint adjustment solution can be compatible withAXandAKXUse together. It can also be used for daily management of Coulomb moisture analyzer.

Used for volumetric titration method


model
code packaging specification main ingredients purpose
AQUAMICRON® Water Standard 10 AWS100 8mLx10/box Titration volume
10±0.5 mg H2O/g
propylene carbonate Used to determine the titration volume of Karl Fischer reagent
AQUAMICRON® Standard Water/Methanol GMW20 250mLglass bottle 水分
2.0±0.04 mg H2O/g
methanol Used for calibrating the titration degree of Karl Fischer reagent(3-10 mg H2O/mL), can also be used for reverse titration

Used for vaporization method

model code packaging specification main ingredients purpose
AQUAMICRON® Solid Water Standard
Solid water standard solution
SWS 10gglass bottle 水分
3.83 ±0.1%
Potassium Tartrate/
Potassium tartrate hemihydrate