Medical grounding resistance tester

NegotiableUpdate on 12/15
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The RK9930Y medical grounding resistance tester is a high-performance safety tester designed with high-speed MCU and large-scale digital circuits. The output current is controlled by hardware feedback and high-speed MCU technology, ensuring stable and reliable output current. The output current is driven by DDS+power amplifier, and the output waveform is pure with little distortion. It can display current and resistance values in real time, and has software calibration function. It is equipped with PLC interface, RS232C, RS485, USB device, USB Host interface, which can easily form a comprehensive testing system with computer or PLC. Can quickly and accurately handle household use

Product Details

Product Introduction

RK9930YMedical grounding resistance testerHigh performance safety testers are designed using high-speed MCUs and large-scale digital circuits. The output current is controlled by hardware feedback and high-speed MCU technology, ensuring stable and reliable output current. The output current is driven by DDS+power amplifier, and the output waveform is pure with little distortion. It can display current and resistance values in real time, and has software calibration function. It is equipped with PLC interface, RS232C, RS485, USB device, USB Host interface, which can easily form a comprehensive testing system with computer or PLC. Capable of quickly and accurately conducting comprehensive safety measurements on household appliances, instruments, lighting appliances, electric heating appliances, computers, and information systems. This instrument complies with IEC60335-1, GB4706.1, UL60335-1 Safety Requirements for Household and Similar Electrical Appliances Part 1: General Requirements UL60950, GB4943, IEC60950 Information Technology Equipment UL60065, GB8898 IEC60065 Safety Requirements for Audio, Video and Similar Electronic Machinery IEC61010-1, GB4793.1 Safety Requirements for Measuring, Control and Laboratory Electrical Equipment Part 1: General Requirements.

This productComplies with the medical standard GB9706.1-2020 (IEC60601-1:2012).


Application field

Medical equipment: various new medical instruments and medical supporting instruments, cardiac monitoring, medical imaging, biochemical analysis instruments, thermometers and other home medical equipment

Auxiliary equipment: medical nursing data and image processing equipment, rehabilitation equipment for disabled persons, etc
Oral medical equipment: dental diagnostic medical equipment, dental surgical instruments, dental technician equipment
Medical magnetic resonance equipment



Performance Characteristics

1. Using a 5-inch LCD display, the displayed parameters are eye-catching and intuitive. Using DDS digital signal synthesis technology to generate waveforms with stable accuracy, purity, and low distortion
2. Constant current output: The output current stability range is within 1%, avoiding changes in output current caused by unstable input current and voltage, as well as load variations.
3. It has an open circuit alarm function. The maximum testing time is 999.9 seconds.
4. Measure using the four terminal method to eliminate the influence of contact resistance.
5. Output frequency 50Hz/60Hz is optional. It has the function of alarm for upper and lower limits of resistance.
6. Bilingual operation interface in Chinese and English, suitable for different user needs, supports large capacity storage, and adapts to different testing application requirements


RK9930Y/RK9930AY/RK9930BYMedical grounding resistance testerRK9930Y
Current range: AC (3-30) A
Voltage range: AC 6V Max open circuit voltage
Rk 9930 is
Current range: AC (3-40) A
Voltage range: AC 8V Max open circuit voltage
RK9930BY
Current range: AC (3-60) Voltage range: AC 12V Max Open circuit voltage


model

RK9930Y

Rk 9930 is

RK9930BY

Basic specifications

screen size

5-inch TFT LCD screen

Number keys

Parameter setting numerical input

coding switch

Parameter selection and confirmation function

Up, down, left, right function keys

Parameter setting up and down selection function

LOCK locking function

Prevent accidental modification of test conditions or prohibit modification of test conditions

alarm function

Voice alarm

communication interface

RS232C、RS485、USB

USB port

Copy, duplicate, and storage functions

control interface

HANDLER(PLC)

current

current range

AC (3-30)A

AC (3-40)A

AC (3-60)A

resolution

When 10A or above: 0.01A/step; When below 10A: 0.001A/step;

accuracy

± (2% set value+0.02A)

voltage

voltage range

AC 6V Max open circuit voltage

AC 8V Max open circuit voltage

AC 12V Max open circuit voltage

frequency

50/60Hz selectable

waveform

sine wave

ammeter

Measurement range of ammeter

AC (3-30)A

AC (3-40)A

AC (3-60)A

resolution

When 10A or above: 0.01A/step; When below 10A: 0.001A/step;

accuracy

± (2% set value+0.1A)

ohmmeter

ohmmeter

0-510m Ω, output current

0-600m Ω, output current

0-600m Ω, output current

measurement range

3-10A; 0-120m Ω, output current 10A-30A

3-10A; 0-200m Ω, output current 10A-30A;
0-150m Ω, output current 30A-40A

3-15A; 0-300m Ω, output current 15A-30A; 0-100m Ω, output current 30A50A, 0-60m Ω, output current 50A-60A

resolution

When 10A or above: 0.01A/step; When below 10A: 0.001A/step;

accuracy

≤± (2% reading value+1m Ω)

Timer Range

0-999.9S, Resolution: 0.1S/step, Accuracy: ≤± 50ms

compensation method

Manual or automatic, maximum Offset: 100m Ω Max, accuracy: ≤± (2% reading+1m Ω)

Determination value setting resistance

0-510m Ω or 0-600m Ω, resolution: 1m Ω, accuracy: ≤± (2% reading+1m Ω)

Upper limit range

Test time

0-999.9S, 0 represents continuous

Scope setting

Working temperature and humidity

0℃-40℃,≦75%RH

power supply

100V-121V,198V-242V,47.5-63Hz

weight

12.15KG

13.05KG

12.75KG

Standard accessories

Upper computer software (download), grounding test clip, power cordRS232 serial port connection cable

Optional accessories (complete set)

RS232 to USB connection cable, USB to square port connection cable, RK00031, RK301 grounding point inspection box, RK00070 serial port option LAN port