Multi effect tubular distilled water machineDetails:
(1) The tubular multi effect distilled water machine is purchased as an equipment package. The supplier shall provide documents, equipment, configuration, installation, testing, and conduct trial runs of all electric components to achieve the specified functions of the machine.
(2) All electrical and instrumentation equipment should meet the standards and meet the requirements of normal working conditions.
(3)Multi effect tubular distilled water machineThe assembly/components should be carefully selected to meet the requirements of EMC (electromagnetic compatibility) specifications.
(4) Provide dedicated uninterruptible power supply from the factory area for the data visualization system to maintain its stable operation.
(5) Relatively independent power terminals need to be installed in the system power cabinet to provide two types of power: 220VAC uninterruptible power supply (L/N/PE) and conventional power supply 380VAC (3L/N/PE).
(6)Multi effect tubular distilled water machineThe supplier shall provide records of all control, regulation, process, interlocking, alarm, and equipment related functions performed by the supplier. Suppliers should provide backup programs.
(7) The system adopts automatic control and is initiated by HMI (Human Machine Interface). The HMI (Human Machine Interface) is in Chinese mode and displays graphics. The HMI (Human Machine Interface) operation mode should be easy for the operator to use and understand.
(8) Standard data communication interface is used to connect with other computer systems
(9) After a sudden power interruption, the control system and print recorder should ensure that data is not lost and print from the breakpoint.
(10) The control system meets the requirements of GAMP5, and the software conducts comprehensive document recording and change control. Different versions of software should provide version records.
(11) The HMI (Human Machine Interface) display should provide operation monitoring, operator interface, alarm monitoring, alarm summary, and system diagnosis. After all parameters are confirmed, the screen displays "Ready", and then the device runs. The operator can operate the device on the operator interface screen by programming function keys and selecting numbers through input. The diagnostic display provides all input, output, count, and time statuses.