MY-Q50 portable pressure calibrator

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The MY-Q50 portable pressure calibrator is a high-precision pressure measurement calibration instrument. It can calibrate and calibrate negative pressure instruments such as pressure (differential pressure) transmitters, pressure sensors, pressure switches, and general (precision) pressure gauges. The vacuum pressure calibrator is a combination of a precision digital pressure gauge and a portable handheld air pressure pump. High precision, good stability, easy manual pump pressurization, stable pressure value freezing, strong air tightness.

Product Details

MY-Q50Portable pressure calibratorCalibrate instruments for high-precision pressure measurement. It can calibrate and calibrate negative pressure instruments such as pressure (differential pressure) transmitters, pressure sensors, pressure switches, and general (precision) pressure gauges. The vacuum pressure calibrator is a combination of a precision digital pressure gauge and a portable handheld air pressure pump. High precision, good stability, easy manual pump pressurization, stable pressure value freezing, strong air tightness.

MY-Q50便携式压力校验仪

Advantages of portable pressure calibrator:
1. Full range pressure calibration, equipped with high-precision imported pressure sensors and full range pressure pumps.
2. Verify various pressure instruments on site or in the measuring room.
3. Accurately measure the current within the range of 0-20mA.
4. Provide 24VDC output as the working power supply for the tested instrument.
5.MY-Q50Portable pressure calibratorYou can directly operate and calibrate the full range on the panel.
6. Constant current charging, with automatic shutdown and protection functions for overcharging and undervoltage of battery voltage.
7. Portable metal casing, strong anti-interference, sturdy and impact resistant.
Technical specifications of portable pressure calibrator:
1. Range: (-95~1.6) MPa (-95~1.6) MPa, (-95~2.5) MPa, (-95~4) MPa(-95~6)Mpa、(0~1.0)Mpa、(0~1.6)Mpa、(0~2.5)Mpa、(0~4)Mpa、(0~6)Mpa(can be selected within this range);
2. Current range: (0-20) mA;
3. Resolution: Pressure Min 1Pa; Current Min 1 μ A;
4. Accuracy level: 0.05% F • S;
5. DC output: 24VDC;
6. Display mode: dual row display of pressure and current;
7. Environmental temperature: 5-50 ℃;
8. Relative humidity: ≤ 80% RH;
9. Overload capacity: 1.2-1.5 times the upper range limit;
10. Power supply method: Built in high-performance lithium battery rechargeable, external 220VAV 50HZ 3VA;
11. Working hours: Continuous working hours ≥ 10 hours;
12. Weight: 1kg;
13. Installation interface: M20 × 1.5.


Usage operation:

1. Power on, key: Press the "on" button to turn on, and the LCD will display the measurement status; Press the 'off' button to shut down the instrument panel and cut off the power supply.

2. Zero calibration button: Before measurement, press the "Zero calibration" button once, and the instrument will automatically collect the zero value of the sensor and send it to the CPU for processing, ensuring that the data measured by the instrument is actualPressure value.

3. Pressure button: After turning on, the pressure unit of the instrument is displayed in the lower right corner of the LCD. If you press the "Unit" button during use to make the LCD display any unit of "MPa, KPa, Psi, Bar, mmHg, Kgf/cm2", press the "Pressure" button, and the instrument will automatically switch to the factory set pressure single level. When the measured current needs to be displayed, press the "Pressure" button when the instrument display unit is MPa (or KPa), and the corresponding current indicator light on the panel will light up, indicating the measured current state.

Precautions for use:

1. The instrument should be placed in a dust-free and non corrosive environment. If there are special requirements, please specify them in the contract.

When the instrument is not in use, the power should be turned off. If it is not in use for a long time, it should be charged once every three months.

3. The instrument has sufficient overload capacity, but do not overload it severely, otherwise it will cause damage to the sensor and render the instrument unusable.

4. Instrument sensors belong to high-precision products, and the surface of the silicon diaphragm should not collide with solids, otherwise it will damage the sensor.

5. Without professional testing skills and specialized testing equipment, do not open the hood for maintenance, and do not adjust internal components or replace materials, otherwise the reliability of the instrument cannot be guaranteed.

6. Do not let electric soldering irons or other heating elements near the display screen to prevent burning and damaging the plastic material.

7. Do not use chemical solvents such as gasoline and alcohol to clean the panel.

Although the instrument has seismic design, it should still be handled with great care and not dropped or collided when used on site.

deposit:

Instruments should be avoided from being stored in the following locations

1. High humidity

2. Near high-temperature heat sources

3. There is strong vibration present

4. Corrosive gases

enclosure:

1 password box

1 copy of instruction manual

1 certificate of conformity

1 data cable

1 charger

1 copy of factory inspection report

Introduction to Precision Digital Pressure Gauge:


The precision digital pressure gauge adopts imported MCU and high-resolution AD converter, which can meet the requirements of high precision and low power consumption. Large screen LCD display, clear and easy to read data. The shell is made of stainless steel, which is corrosion-resistant and resistant to mechanical pressure. The entire body adopts sealing technology and can be applied in various complex environments. It is an ideal choice to replace traditional mechanical watches. It can be used as a high-precision calibration standard (gauge) to calibrate and verify pressure/differential pressure transmitters, pressure sensors, pressure switches, ordinary/precision pressure gauges, etc. It can also be used for online pressure measurement. This product is widely used in metrology, school research, natural gas, power, metallurgy, petroleum, chemical and other metrology departments for inspection and measurement.

Precision digital pressure gauge processability:

1. The measurement range is optional: ± 100KPa; -100-250KPa; -100-600KPa; -95-100KPa; -95-600KPa; 0-100KPa; 0-600KPa...

-0.1-0MPa; -0.1-1MPa; -0.1-2MPa; -0.1-3.5MPa; 0-0.1MPa; 0-0.6MPa; 0-0.6MPa; 0-1MPa; 0-1.6MPa; 0-2.5MPa; 0-4MPa; 0-6MPa; 0-10MPa; 0-16MPa; 0-25MPa; 0-40MPa; 0-60MPa. ..

±500Pa; ±1000Pa; ±2000Pa; ±5000Pa; 0-1000Pa; 0-5000Pa. ..

0 - 100 mmHg ; 0 - 200 mmHg ; 0 - 300 mmHg ; 0 - 400 mmHg. ...

-0.145~+0.145PSi; 0-145PSi; 0-500PSi; 0-600PSi; 0-1450PSi; 0-8700PSi. ..


2. Resolution: Pressure: Min 1Pa

3. Wide screen, 5-digit large character, 6-digit large character clear and intuitive

4. Accuracy: 0.05% F.S, 0.1% F.S, 0.2% F.S, 0.4% F.S, 0.5% F.S, etc

5. DC output: 24V · DC

6. Environmental temperature: 5~50 ℃ Operating temperature: -20~80 ℃

7. DC working time: ≥ 40 hours

8. Display: 41/2LCD 51/2LCD

9. Relative humidity: ≤ 80% RH

10. Overload capacity: 1.2 to 1.5 times the upper range limit

11. Shell diameter: 110mm

12. Weight: 1kg

13. Power supply: External charger 220VAC 50Hz 3VA

14. Installation connector: National standard M20X1.5 (other thread specifications can be customized according to on-site requirements)