E-mail
3892196252@qq.com
-
Phone
13329186925
-
Address
Building 2, Shengfeng Software Park, Huashan District, Ma'anshan City, Anhui Province
Ma'anshan Maisite Intelligent Technology Co., Ltd
3892196252@qq.com
13329186925
Building 2, Shengfeng Software Park, Huashan District, Ma'anshan City, Anhui Province
MSTX200YQ Smoke Online Monitoring System:
The MSTX200YQ series continuous emission monitoring system (CEMS) for flue gas can continuously monitor fixed pollution sources online for a long time. Mainly used for desulfurization and denitrification control systems in power plants and waste incineration plants, monitoring of exhaust emissions from solid waste treatment, combustion control systems, flue gas emission systems, and urban environmental protection, achieving fully automatic unmanned operation and remote control diagnosis and data transmission through remote communication. This complete system adopts ultraviolet differential absorption spectroscopy technology and extraction hot wet detection principle technology to perform online analysis of SO2, NOx, O2, CO, flue gas humidity, smoke concentration, flue gas flow rate, flue gas temperature, flue gas pressure and other components in flue gas. The characteristics of this system are anti blocking sampling, anti-corrosion and anti background gas interference, which effectively solves the problem of sampling pretreatment under harsh working conditions such as high dust, high temperature, high humidity, high viscosity, etc. The entire system consists of monitoring of smoke particle concentration, monitoring of flue gas parameters (flue gas flow rate, flue gas temperature, flue gas pressure, flue gas oxygen content, etc.), data acquisition and processing, and communication.

MSTX200YQ Smoke Online Monitoring SystemFeatures:
Advantage 1: Based on the hot and humid extraction full process high-temperature tracing method, accurate measurement can be achieved without any condensation or water removal pretreatment of the extracted sample gas. The analytical instrument is placed indoors in a suitable environment, and monitoring and maintenance are convenient, avoiding the disadvantages of traditional extraction methods such as complex pretreatment, water dissolution loss of SO2 caused by condensation, and easy corrosion and crystallization blockage of pipelines;
Advantage 2: Adopting high-temperature jet extraction technology, the structure is very simple, with no moving parts, high temperature resistance, corrosion resistance, and greatly enhanced reliability;
Advantage 3: The sampling probe combines multi-stage dust filtration technology with timed blowback, effectively solving the problem of probe blockage and adapting to harsh environments such as high dust, high humidity, high temperature, and high corrosiveness;
Advantage 4: The gas chamber of the analyzer is made of stainless steel processing, which does not require mirror polishing or gold plating inside. The gas chamber is strong, low-cost, and less affected by moisture and dust. The detector and gas chamber are connected by optical fibers, which is easy to replace and has low maintenance costs;
Advantage 5: * UV differential absorption spectroscopy technology, spectral holographic grating splitting, diode array detection, obtaining complete continuous absorption spectra, high wavelength resolution ensures low detection limit, small temperature drift, and small response time;
Advantage 6: The temperature pressure flow detector adopts an integrated cabinet, high-precision micro differential pressure transmitter (with low detection limit), automatic zero adjustment, automatic blowback, blowback protection, data upload and display functions;
System technical parameters:
▌ Maximum sampling temperature: 600 ℃
Maximum working pressure: 6 BAR
Heating temperature: Sampling probe 140 ℃ (factory setting, adjustable temperature) Heat tracing tube 120 ℃
Environmental temperature: -20 ℃ to 80 ℃
Maximum dust concentration: 100mg/m ³
▌ Filtration accuracy: 0.1 μ m
Linearity: ≤ 1%
Accuracy: ≤ 1%
Zero drift: ± 1%/week, ± 2%/year
▌量程漂移: ±1% / 周, ±5%/年
Calibration method: manual/automatic
Communication interface: RS485, 4-20mA signal output
Common parameters for CEMS flue gas monitoring: