MINI-X1-Y1-Z1 series six axis fiber coupling platform

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The MINI-X1-Y1-Z1 series six axis fiber optic coupling platform is designed specifically for fiber optic coupling. It innovatively integrates a three-axis micro precision adjustment mechanism on the basis of the ART130 series large stroke motion table (XYZ axis stroke can be customized according to customer needs), achieving an integrated operation of "wide range coarse adjustment+nanometer level fine adjustment". The repeated positioning accuracy of each axis can reach; #177; Within 100nm. The product is suitable for the vast majority of optical communication module applications and has industrial integration advantages of high precision, high stability, and high cost-effectiveness.

Product Details

MINI-X1-Y1-Z1 series six axis fiber coupling platformSpecializing in the design of fiber optic coupling links, we innovatively integrated a three-axis micro precision adjustment mechanism on the basis of the ART130 series large stroke motion table (XYZ axis stroke can be customized according to customer needs), achievingThe integrated operation of "large-scale coarse adjustment+nanoscale fine adjustment" ensures that the repeated positioning accuracy of each axis can reach within ± 100nmThe product is suitable for the vast majority of optical communication module applications and has industrial integration advantages of high precision, high stability, and high cost-effectiveness.


Unlike previous piezoelectric micro stage adjustment schemes, we still use self-developed linear motors and cross roller guides. The micro motion stroke of MINI axis can achieve ± 1mm, and the motion setting time can reach 200 μ m @ ± 50nm @ 30ms.MINI-X1-Y1-Z1 series six axis fiber coupling platformThe ultra-high precision and compact size, lighter weight and wider range of travel make it more suitable for coupling scenarios that require frequent, fast, and large-scale back and forth movement.


MINI XYZ in-situ stability

MINI-X1-Y1-Z1系列六轴光纤耦合平台


MINI X-axis setting speed

MINI-X1-Y1-Z1系列六轴光纤耦合平台


MINI Y-axis setting speed

MINI-X1-Y1-Z1系列六轴光纤耦合平台


MNI Z-axis setting speed

MINI-X1-Y1-Z1系列六轴光纤耦合平台



Axis name

X

Y

Z

MINI-X

MINI-Y

MINI-Z

itinerary

60mm

60mm

35mm

1mm

1mm

1mm

Electronic resolution

5nm

定位精度

±250nm

±250nm

±250nm

±200nm

±200nm

±200nm

Repetitive positioning accuracy

±100nm

±100nm

±100nm

±100nm

±100nm

±100nm

straightness

±1.5μm

±1.5μm

±2μm

N/A

N/A

N/A

flatness

±1.5μm

±1.5μm

±2μm

N/A

N/A

N/A

Pitch

10arcsec

10arcsec

10arcsec

N/A

N/A

N/A

Yaw

10arcsec

10arcsec

10arcsec

N/A

N/A

N/A

Minimum step

50nm

Positioning stability

±50nm

±50nm

±50nm

±50nm

±50nm

±50nm

Exercise setting time

/

200μm
@± 50nm@30ms

200μm
@± 50nm@30ms

200μm
@± 50nm@30ms

Mini axle load weight

500g

maximum speed

500mm/s

500mm/s

500mm/s

50mm/s

50mm/s

50mm/s

Platform weight

11kg

Platform material

aluminium

averageStable movementtime

27,000 Hours



Note:

(1) Adaptation - AS feedback, linear amplifier;

(2) No load, corresponding power amplifiers need to be configured;

(3) The default test point position is 25mm above the tabletop;

(4) The rest of the itinerary can be customized.



MINI axis parameters
Axis name MINI-X MINI-Y MINI-Z
itinerary 1mm 1mm 1mm
Electronic resolution 5nm
定位精度 ±200nm ±200nm ±200nm
Repetitive positioning accuracy ±100nm ±100nm ±100nm
Minimum step 50nm
Positioning stability ±50nm ±50nm ±50nm
Exercise setting time 200μm@± 50nm@30ms 200μm@± 50nm@30ms 200μm@± 50nm@30ms
load weight 500g
maximum speed 20mm/s 20mm/s 20mm/s
Continuous thrust 8.4N
Peak thrust 66.5N
Platform weight 1.3kg
Platform material aluminium
Average stable exercise time 27,000 Hours


Note:

(1) Adaptation - AS feedback, linear amplifier;

(2) No load, corresponding power amplifiers need to be configured;

(3) The default test point position is 25mm above the tabletop.