- Phone
-
Address
30th Floor, Science and Technology Capital West Building, Beijing East Road, Shanghai
Shanghai Chengli Electronic Technology Co., Ltd
30th Floor, Science and Technology Capital West Building, Beijing East Road, Shanghai
Logic analyzer probe
TLP058goods in stock!
The verification and debugging of high-speed, low-voltage digital signals today require detection solutions that can accurately collect and protect signal fidelity from various electronic designs. TechLogic analyzer probeIt includes multiple connection options, and its design ensures that signal acquisition can truly reflect the performance of the design. Compare and learn more about TektronixLogic analyzer probesolution
TLP058 is an 8-channel logic probe designed by Tektronix for its FlexChannel series mixed signal oscilloscopes (MSOs), used to connect the oscilloscope to the digital bus of the device under test.
Here is its core information:
Product Overview and Key Features
*Basic function: Expand the FlexChannel input of an oscilloscope into 8 independent digital logic input channels for measuring multiple digital signals simultaneously.
*Core features:
*High bandwidth and sampling rate: With a bandwidth of 500 MHz and a sampling rate of 6.25 GS/s, it is suitable for high-speed digital signal debugging.
*High input impedance: The input resistance is 100 k Ω and the input capacitance is only 3.0 pF, which can effectively reduce the load impact on the tested circuit.
*Wide threshold range: The threshold voltage range reaches ± 40 V, which can adapt to a wider range of logic levels.
*High sensitivity: The minimum detectable pulse width is 1 ns, which can capture very narrow pulses.
Compatible oscilloscope models
TLP058 is designed specifically for Tektronix's MSO series with FlexChannel interface, and is mainly compatible with specific models in the following series:
*5 Series MSO: including MSO54, MSO56, MSO58, MSO58LP.
*6 series MSO: such as MSO64.
*4 Series MSO: Also supports using TLP058 to convert each FlexChannel into 8 digital channels.
Main technical specifications
*Input channel: 8 digital channels
*Input voltage range: 30V
*Minimum input signal swing: 400mV p-p
*Digital to analog trigger offset: 5ns
*Probe length: 1.0 meter
*Working temperature: 0 ° C to+50 ° C
How to use and connect
1. Connect the oscilloscope: Turn the probe locking lever to the "unlocked" position, insert the probe into the FlexChannel connector of the oscilloscope until a "click" sound is heard, and then turn the locking lever back to the "locked" position. At this time, the status indicator light should be * * constantly on green * *.
2. Automatic configuration: After the probe is connected, the oscilloscope usually automatically detects and configures channels.
3. Connect the tested circuit: Use the probe wires and adapter in the accessory kit to connect the probes and ground wires of the 8 channels to the corresponding test points of the tested device.
Usage tips and suggestions
*Automatic recognition: TLP058 is designed to be plug and play, and the oscilloscope can automatically recognize the probe type after connection.
*Signal verification: If the expected signal activity cannot be seen on the digital channel, it is recommended to use an analog probe (such as a standard passive voltage probe) connected to the same test point to verify whether the signal itself is normal.
*Safe operation: To avoid damaging the equipment, it is necessary to first power off the tested circuit before connecting or disconnecting the probe.
In summary, TLP058 is a high-performance logic probe that can expand a single input of Tektronix FlexChannel MSO into 8 digital channels, making it ideal for debugging tasks that require simultaneous observation of multiple digital buses or signals (such as power timing, parallel buses, multi-channel digital IO, etc.).