- Phone
-
Address
Building B, No. 3, 3rd Road, Yangyong Industrial Zone, Songgang Street, Bao'an District, Shenzhen
Shenzhen Ruitaier Technology Co., Ltd
Building B, No. 3, 3rd Road, Yangyong Industrial Zone, Songgang Street, Bao'an District, Shenzhen
Liquid high and low temperature cycling test chamberCan meet the following two testing requirements, as detailed in the attached technical document.
Temperature fluctuation test (water-cooled assembly)
experimental medium:70%ethylene glycol+30%Water solution or50%ethylene glycol+50%aqueous solutionThe medium temperature is consistent with the ambient temperature,heating and cooling2.5~10℃/min,
The process is as follows:
1temperature from+0℃ rises to+85℃, maintain85℃ maintain15min
2temperature from+85℃ drops to0℃, conversion time is20min, maintain0℃ maintain15min
3Test cycle: number of cycles900time
project |
explanation |
|
product name |
Liquid high and low temperature cycling test system |
|
model |
Customizable according to customer requirements |
|
test scope |
Media work temperature range |
Antifreeze:-40℃~+ 85℃ Water:2℃~+ 98℃ |
|
lift Warm speed rate |
Temperature change rate |
Maximum achievable+85℃~-40℃ about16minInside (about)10℃/min) |
Medium circulation flow rate |
The maximum flow meets25L/min(Real time collection of traffic timing0.6cube/hour) |
|
control system |
Touch LCD screen controller |
|
Note: The load capacity of the equipment is approximately equal to the cold and hot balance2~3KWThe cooling and heating capacity. | ||
Volume of spare medium box(The maximum loadable content area is approximately10L) | ||
|
material quality |
Main skeleton material |
40×40Standard aluminum profiles |
outer box material |
SUS 304#Brushed stainless steel plate |
|
heater |
Customized secondary liquid constant temperature heater |
|
refrigeration compressor |
Adopting imported refrigeration compressor |
|
evaporator |
Coil type multi-channel evaporator |
|
Cooling method |
Mechanical compressor refrigeration |
|
cooling method |
wind cold |
|
Usage environment:Working environment temperature15℃-30Used within ℃ | ||
2、Liquid high and low temperature cycling test chamberHeating, cooling, humidification system and its working principle
project |
Principle Description |
|
|
cold freeze be unify |
Refrigeration compressor |
Using imported refrigeration compressors and environmentally friendly refrigerants |
refrigerant copper pipe |
Internal spiral typeKTYPErefrigerant copper pipe |
|
condenser |
Wave shaped fin type air-cooled condenser |
|
evaporator |
Coil type multi-channel evaporator |
|
Freezing components |
Imported solenoid valve, driedfilterEquipment, etc. |
|
characteristic |
All system pipelines are ventilated and pressurized22kgLeak testing. |
|
thermostatic system independent | ||
Equipped with our company's professional technical features, the refrigeration system is designed to prevent damage from high-temperature and high-pressure airflow backflow | ||
All freezing system action programs, Controlled by a microcomputer controller | ||
3、Liquid high and low temperature cycling test chamberregulating system
project |
explanation |
adjustment method |
Forced circulation flow, balanced temperature regulation method. The control system passes through the temperature point set by the systemPIDThe result of automatic calculation output is used to control the output of the heater, ultimately achieving a dynamic balance. |
Medium circulation device |
Adopting a closed-loop circulation system with a circulating water pump to force liquid flow. |
Pressure cycle system |
By controlling the secondary air pressure through an electrical proportional valve, the pressure of the medium in the circulation pipeline is pushed to change, so that the pressure change of the liquid meets the requirements of the pressure program change during the testing process The job requirements. |
4Safety protection measures
project |
explanation |
1 |
Leakage protection for power supply; |
2 |
Extreme high and low temperature protection; Temperature deviation alarm; |
3 |
Compressor overheat, overload, overcurrent, overpressure protection |
4 |
Phase sequence missing phase protection; |
5 |
Medium limit working pressure protection |
6 |
Integrated protection system for medium circulation pump |
Liquid high and low temperature cycling test chamberDesign schematic:


(The image is for reference only) Based on the actual product)