Battery thermal shock (thermal abuse) test chamber

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The battery thermal shock testing machine simulates the battery being placed in a high-temperature box with natural convection or forced ventilation, and heats up at a certain heating rate to the set test temperature and maintains it for a certain period of time. It adopts a hot air circulation system to ensure uniform distribution of working temperature.

Product Details

product name

Battery thermal shock (thermal abuse) test chamber

Product Model

RTE-RC5105

Place of Originbrand

Ruitai Er

interface


电池热冲击(热滥用)试验箱

Curve interface


电池热冲击(热滥用)试验箱

Product Overview

The battery thermal shock testing machine simulates the battery being placed in a high-temperature box with natural convection or forced ventilation, and heats up at a certain heating rate to the set test temperature and maintains it for a certain period of time. It adopts a hot air circulation system to ensure uniform distribution of working temperature.

Test standard

After fully charging the battery according to the prescribed test method, place the battery in the test chamber(Raise the temperature at a rate of 5 ℃/min, and maintain a constant temperature for 30 minutes when the temperature inside the box reaches 130 ℃± 2 ℃. Test result: The battery should not catch fire or explode.

Box Structure

1Internal dimensions:500(wide)×500tall)×500deep)mm

2External dimensions:850(wide)×1350(tall)×820(deep)mm,Based on the actual object;

3The controller is located above the front of the machine,PLC+Touch screen control;

4The internal material is:201#steel plate,thick1.2mm

5The outer material is cold-rolled steel plate1.5mmPaint treatment;

6The single door opens to the right, and the observation window of the door is about200*350mmThe specific dimensions are subject to the actual product;

7The pressure relief port is approximately200*200mmLocated at the back of the box, it will automatically pop open when the sample explodes;

8Power on test hole: diameter on the left side of the machine50mmOne;

9. Exhaust port, with a diameter of approximately 100 or 150mm, located at the back of the casing;

10The insulation material is high temperature resistant rock wool, which has good insulation effect;

11The sealing material is:High temperature resistant foam silicone strip;

12The machine is equipped with movable casters with brakes for easy fixation of the moving position;

Temperature Control System

1ThePLC+Touch screen control;

2Time to stop heating;

3Temperature sensing line(K)Type;

4The output is3-32V

5The current controller is solid-stateSSRrelay;

6The heating element is:High temperature resistant honeycomb resistance heater;

7Temperature range: normal temperature+10150℃ temperature adjustable,common130Below the degree;

8Control accuracy ±2℃;

9Display accuracy0.5℃;

10Heating rate: average2~5/min (Linear no-load adjustable)

11Uniformity of temperature distribution inside the box ±2.0% (no-load test)

air supply system

1Forced air circulation, with air outlet on the left side of the inner box and air suction on the right side;

2The motor is a temperature resistant special type, with motor power750W/220V

3The wind turbine is a multi wing turbine type7.5Inch;

4The air inlet is located on the right side of the machine, and the air outlet is located on the left side of the machine;

Power supply device

1VoltageAC 220Vsingle-phase50HZ

2Current20A

3Power consumption3.5KW

Security protection system

1Overtemperature protection system: When the temperature is out of control and exceeds the set temperature for overtemperature protection, the heating power supply will automatically stop, thereby protecting the safety of your products and machines;

2Circuit protection system: grounding protection, quick safety;

data collection

collection channel

select

voltage acquisition

select

Temperature acquisition

select

Record speed

The fastest per second10time

Data export

USB

data type

Table numbers

curve type

picture

main components

name

brand

Place of Origin

custom craftsmanship

High temperature motor

定制

Dongguan


touch screen

Weilun

Shenzhen


controller

定制

Shenzhen

Mitsubishi, JapanCPU

AC contactor

Chint

Zhejiang


residual current circuit breaker

Chint

Zhejiang


explosion-proof box

定制

Dongguan

Precision welding

wire

the Pearl River

Guangzhou


transmitter

Thai-Chinese

Jiangsu


Installation requirements:

6.1Important statement

The following conditions are necessary for normal installation and use, and unless otherwise specified, they are all owned by Party A Provide or guarantee;

6.2Space requirements

Requirements for the size and placement environment of the space occupied for positioning, transportation, and installation;

6.3Positioning channel

By boxbodyThe external dimensions can pass through, but special attention should be paid to corners, entrance dimensions, elevator dimensions, etc;

6.4floor location

For installation sites with vacant spaces upstairs or underground, the load-bearing requirements for the ground of the site≥500kg/m2

6.5Land occupation and surrounding dimensions

电池热冲击(热滥用)试验箱


a.Maintenance space around the equipment, according topressA:≥60cm B:≥60cm C: ≥120cm D: ≥60cm

b. The ground is flat, well ventilated, and free of flammable, explosive, corrosive gases and dust;

6.6

Other requirements for the usage environment

Environmental temperature requirements040℃

humidity requirements70RH

Pressure requirements86KPa106KPa

electromagnetic environmentThere is no strong electromagnetic radiation source nearby;

6.7Safe storage conditions

When the test chamber is not in use, the storage environment of the test chamber should be maintained at all times0℃;