product name |
Battery thermal shock (thermal abuse) test chamber |
|||||||||||||||||||||||||||||||||||||
Product Model |
RTE-RC5105 |
|||||||||||||||||||||||||||||||||||||
Place of Originbrand |
Ruitai Er |
|||||||||||||||||||||||||||||||||||||
interface |
|
|||||||||||||||||||||||||||||||||||||
Curve interface |
|
|||||||||||||||||||||||||||||||||||||
|
Product Overview
|
The battery thermal shock testing machine simulates the battery being placed in a high-temperature box with natural convection or forced ventilation, and heats up at a certain heating rate to the set test temperature and maintains it for a certain period of time. It adopts a hot air circulation system to ensure uniform distribution of working temperature. |
|||||||||||||||||||||||||||||||||||||
|
Test standard
|
After fully charging the battery according to the prescribed test method, place the battery in the test chamber(Raise the temperature at a rate of 5 ℃/min, and maintain a constant temperature for 30 minutes when the temperature inside the box reaches 130 ℃± 2 ℃. Test result: The battery should not catch fire or explode. |
|||||||||||||||||||||||||||||||||||||
Box Structure |
1Internal dimensions:500(wide)×500tall)×500deep)mm; 2External dimensions:850(wide)×1350(tall)×820(deep)mm,Based on the actual object; 3The controller is located above the front of the machine,PLC+Touch screen control; 4The internal material is:201#steel plate,thick1.2mm; 5The outer material is cold-rolled steel plate1.5mmPaint treatment; 6The single door opens to the right, and the observation window of the door is about200*350mmThe specific dimensions are subject to the actual product; 7The pressure relief port is approximately200*200mmLocated at the back of the box, it will automatically pop open when the sample explodes; 8Power on test hole: diameter on the left side of the machine50mmOne; 9. Exhaust port, with a diameter of approximately 100 or 150mm, located at the back of the casing; 10The insulation material is high temperature resistant rock wool, which has good insulation effect; 11The sealing material is:High temperature resistant foam silicone strip; 12The machine is equipped with movable casters with brakes for easy fixation of the moving position; |
|||||||||||||||||||||||||||||||||||||
|
Temperature Control System
|
1ThePLC+Touch screen control; 2Time to stop heating; 3Temperature sensing line(K)Type; 4The output is3-32V; 5The current controller is solid-stateSSRrelay; 6The heating element is:High temperature resistant honeycomb resistance heater; 7Temperature range: normal temperature+10~150℃ temperature adjustable,common130Below the degree; 8Control accuracy ±2℃; 9Display accuracy0.5℃; 10Heating rate: average2~5℃/min (Linear no-load adjustable) 11Uniformity of temperature distribution inside the box ±2.0℃% (no-load test) |
|||||||||||||||||||||||||||||||||||||
air supply system |
1Forced air circulation, with air outlet on the left side of the inner box and air suction on the right side; 2The motor is a temperature resistant special type, with motor power750W/220V; 3The wind turbine is a multi wing turbine type7.5Inch; 4The air inlet is located on the right side of the machine, and the air outlet is located on the left side of the machine; |
|||||||||||||||||||||||||||||||||||||
|
Power supply device
|
1VoltageAC 220Vsingle-phase50HZ 2Current20A 3Power consumption3.5KW |
|||||||||||||||||||||||||||||||||||||
Security protection system |
1Overtemperature protection system: When the temperature is out of control and exceeds the set temperature for overtemperature protection, the heating power supply will automatically stop, thereby protecting the safety of your products and machines; 2Circuit protection system: grounding protection, quick safety; |
|||||||||||||||||||||||||||||||||||||
|
data collection
|
|
|||||||||||||||||||||||||||||||||||||
|
main components
|
|
|||||||||||||||||||||||||||||||||||||
Installation requirements: | ||||||||||||||||||||||||||||||||||||||
6.1Important statement |
The following conditions are necessary for normal installation and use, and unless otherwise specified, they are all owned by Party A Provide or guarantee; |
|||||||||||||||||||||||||||||||||||||
6.2Space requirements |
Requirements for the size and placement environment of the space occupied for positioning, transportation, and installation; |
|||||||||||||||||||||||||||||||||||||
6.3Positioning channel |
By boxbodyThe external dimensions can pass through, but special attention should be paid to corners, entrance dimensions, elevator dimensions, etc; |
|||||||||||||||||||||||||||||||||||||
6.4floor location |
For installation sites with vacant spaces upstairs or underground, the load-bearing requirements for the ground of the site≥500kg/m2 |
|||||||||||||||||||||||||||||||||||||
6.5Land occupation and surrounding dimensions |
a.Maintenance space around the equipment, according topressA:≥60cm B:≥60cm C: ≥120cm D: ≥60cm b. The ground is flat, well ventilated, and free of flammable, explosive, corrosive gases and dust; |
|||||||||||||||||||||||||||||||||||||
|
6.6 Other requirements for the usage environment |
Environmental temperature requirements:0~40℃; humidity requirements:≤70%RH; Pressure requirements:86KPa~106KPa; electromagnetic environment:There is no strong electromagnetic radiation source nearby; |
|||||||||||||||||||||||||||||||||||||
6.7Safe storage conditions |
When the test chamber is not in use, the storage environment of the test chamber should be maintained at all times0℃; |
|||||||||||||||||||||||||||||||||||||