Welcome Customer !

Membership

Help

Zhongyuan Standard Material Center
Custom manufacturer

Main Products:

instrumentb2b>Products

Zhongyuan Standard Material Center

  • E-mail

  • Phone

  • Address

    No. 98-21 Nanping Road, Erqi District, Zhengzhou City

Contact Now

Liquid chromatography UV detection linear range standard solution

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The liquid chromatography UV detection linear range standard solution kit is provided by Zhongyuan Standard Material Center (Henan Detong Environmental Protection Technology Co., Ltd.), with specifications of 5ml * 10/10ml * 10/20ml * 10. Welcome to contact us for consultation!

Product Details

Model:JJG 705-2014- Customization

NameLiquid chromatography UV detection linear range standard solution

Packaging: 5ml * 10 pieces

Purpose:Linear range of UV detection in liquid chromatography

Liquid chromatography UV detection linear range standard solutionSpecific steps (instructions for use):

Connect the detector to the data processing system, set the wavelength of the detector to 254nm, and after stabilizing the power supply, use a syringe to directly inject 2% YBC aqueous solution into the detection cell and rinse it until the reading stabilizes. Record this value. Then, according to the above method, inject BT-2% YBC series aqueous solutions (BT content of 0.1%, 0.2%,...) into the detection cell in sequence ..., 1.0%), and record the stable response signal values corresponding to each solution. Repeat the measurement three times for each solution and take the arithmetic mean. Using 5 BT solution concentrations (0.1%, 0.2%, 0.3%, 0.4%, 0.5%) and corresponding response signal values as standard curves, find the readings of acetone solution concentrations greater than 0.5% at each point on the curve, compare them with the corresponding measured values at each concentration point, and determine the concentration with a difference of 5% as the detection upper limit CH. The minimum detection concentration obtained according to c) in 6.2.2.4 is the detection lower limit CL value, and the CnH/CL ratio is the linear range.

JJG 705-2014 liquid chromatography UV detection linear range requires the following standard solutions:

液相色谱仪紫外检测线性范围标准溶液

Liquid chromatography UV detection linear range standard solutionPlease contact customer service.


More standard solutions are availableZhongyuan Standard Material Center (Henan Detong Environmental Protection Technology Co., Ltd.)Welcome to inquire!