Light scattering microcomputer laser dust analyzer

NegotiableUpdate on 01/11
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The TC-PM21 microcomputer laser dust analyzer with light scattering has a built-in filter membrane online sampler. While continuously monitoring the dust concentration, it can collect particulate matter for analysis of its composition and calculate the mass concentration conversion coefficient K value. It can directly read the dust mass concentration (mg/m) and has PM10, PM5, PM2.5, PM1.0, and TSP cutters to choose from.
Product Details

TC-PM21 typeLight scattering microcomputer laser dust analyzer


Product Parameters

1. Equipped with a lifting protection system, it can detect concentration and collect dust samples at the same time.

2. Can detect PM10, PM5, PM2.5, PM1, TSP, and total dust

PM10 particulate matter capture characteristics Da50=10 μ m ± 0.5 μ m, б=1.5 ± 0.1

The capture characteristics of PM2.5 particulate matter are Da50=2.5 μ m ± 0.2 μ m and б=1.2 ± 0.1.

Da50 is the aerodynamic diameter of particulate matter corresponding to a capture efficiency of 50%; σ g is the geometric standard deviation of capture efficiency.

Note 1: The corrected particles are polystyrene particles with an average particle size of 0.6 μ m and a geometric standard deviation of б ≤ 1.25;

Note 2: CPM is a method of expressing relative concentration by counting pulses per minute

3. LCD display direct reading of dust mass concentration (mg/m3)

4. Measurement sensitivity: For calibration particles, the instrument counts 1CPM=0.001mg/m3;

5. Repetitive error: ± 2%;

6. Relative measurement error: For calibrated particles, the relative measurement error is less than ± 10%;

7. Measurement range: 0.001-100 mg/m3

8. Equipped with the function of eliminating humidity interference (humidity correction), it can be used under conditions of high relative humidity (>50%) in the environment.

9. Equipped with a powerful suction pump, it can reduce the impact of air velocity on measurement results.

10. Measurement time: Standard time is 1 minute, and the sampling time can be set according to customer requirements.

11. Measurement mode: general measurement, continuous monitoring, labor hygiene.


product standard

Sanitary Code for Central Air Conditioning and Ventilation Systems in Public Places WS394-2012

GB/T18204.2-2014 "Methods for hygiene inspection of public places - Part 2: Chemical pollutants"

GB/T18204.5-2015 "Methods for hygiene inspection of public places - Part 5: Central air conditioning and ventilation systems"

JJG846-2015 "Dust Concentration Measuring Instrument"

Satisfy: GB/T 34012-2017 standard for air purification devices for ventilation systems, including requirements for dust testers for purification effect testing


Product Application

TC-PM21 typeLight scattering microcomputer laser dust analyzerSuitable for detecting PM10 inhalable particulate matter concentration at central air conditioning exhaust outlets that require longer sampling tubes, and monitoring environmental conditions for inhalable dust PM2.5.