Legionella pneumophila is a ubiquitous bacterium that often appears in air conditioning systems and secondary water supply systems during summer. It has the ability to grow in natural habitats and adapt to other environments with similar characteristics, such as the human body. If not detected and treated in a timely manner, it has a high mortality rate. If inhaled, Legionella pneumophila can enter the lungs for replication, leading directly to a life-threatening infection: Legionnaires' disease.
In previous tests, Legionella was a difficult bacterium to cultivate and detect.
Using Mika,Now it can be detected and counted by culturing in a petri dish for 48 hours (standard method takes 10 days)---Legionella pneumophila.
Legionella Rapid Detection SystemProduct Features:
1. The equipment is developed based on the ISO 11731 standard method and complies with standards such as GBT18204-2013
2. Comply with the provisions of 21CRF Part 11
3. By using fluorescence detection technology and revolutionary optical equipment, all serotypes of Legionella pneumophila can be detected
4. Legionella pneumophila can be detected after 48 hours of cultivation (traditional methods require 10 days of cultivation)
5. Using cell non-toxic programs, the bacteria cultured and tested still have high activity, which can be used for later detection and other identification
6. The device can take 70 high-definition photos during each inspection
7. The device has an image reconstruction program that can re overlay the captured images.
8. The equipment is equipped with artificial intelligence to analyze membrane images.
9. The device can eliminate interference fluorescence signals from non target microorganisms and perform microcolonial calculations for Legionella pneumophila.
10. Integrated LIMS system, capable of data analysis and export
11. Each user sets up their own user account and logs in individually.
12. Optional printer and scanning function
Legionella Rapid Detection SystemTechnical Indicators:
Sample specification: 48mm diameter filter membrane
Detection type: fluorescence and bright field
Obtain the total number of bacterial colonies for each sample as a result
The diameter of the object being tested is ≥ 10 µ m
There are quantitative methods available
Detection area with a membrane diameter of 38mm
Scanning type: Automatic multi-color intelligent scanning
Each membrane captures 70 images
Focusing preset focus
Light source LED
Analysis Report Format PDF
Data export format CSV
Connect USB and Ethernet ports
240GB of memory
Screen Touch Screen