Intelligent Ultra Pure Water System

NegotiableUpdate on 01/28
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Genie PURIST uses pure water (EDI pure water, RO water, distilled water, etc.) as the inlet to prepare laboratory ultrapure water. The quality of the produced water meets or exceeds the Chinese laboratory water standards and test methods (GB6682-2008) and the quality standards of first grade water according to ASTM, CLSI, and ISO3696. The PURIST intelligent ultrapure water system has obtained CE and RoHS certifications.
Product Details

PURISTIntelligent Ultra Pure Water SystemInnovative features:

The main control screen, water dispenser system, and water intake handle can be wirelessly connected and placed as needed to save space; Remote control, remote diagnosis, reliable data transmission

High sensitivity touch screen, integrated buttons, durable and long-lasting, can carry water, and can be operated with latex gloves

Purification columns, ultraviolet lamps, terminal filters, pumps, and other consumable accessories are equipped with intelligent identification codes, which are scanned and recognized by the host for intelligent information management: real-time monitoring of work status, installation and maintenance signature confirmation, and full traceability. Convenient authentication

RephiBio terminal filter is used to prepare ultrapure water without pyrogens (endotoxins), nucleases, and bacteria for biochemical analysis and molecular biology

• Inlet conductivity detection


Advantages and Characteristics:

• Optional full oxidation method online TOC detection system, online monitoring of TOC content in water

Ultra pure water terminal is compatible with various terminal filters for removing specific target pollutants, "one machine, multiple waters"

LeFil and OrganeFil formula packed ultra purification columns

Suitable for various terminal filters, and can choose ultra purification columns with different formula fillers - low magnesium type, low organic matter type, low boron type, ICP type, DI type, etc., to accurately meet the specific needs of users

Can be equipped with a dedicated stepless liquid level detector, suitable for various types of water storage devices, to prevent air from entering the system

The system comes with a leak protection function, which automatically shuts down when there is a leak

Reserve 10 water intake handle interfaces, which can be added as needed

The water intake handle can view water quality information, adjust flow rate, and quantitatively intake water

The water handle is comfortable to hold, easy to operate with one hand, and convenient to use

The water intake handle bracket can be raised and lowered freely, with a 360 ° rotation and an anti slip base

The main control screen is an 8 'touch screen, which can complete all system settings, operations, and monitoring, and check the system status at any time

The main control screen can be read at a suitable angle and height, which is comfortable and convenient

The main control screen is moisture-proof, dustproof, wear-resistant, resistant to electromagnetic waves, and interference free

Purification column with high column capacity, optimized waterway design, high water flow rate, stable water quality

Purification column body pressure resistancestrongDouble sealed interface, low risk of water leakage

Tag, color, chip triple foolproof, installation of intelligent positioning


Main applications:

ultrapure water

The supporting selection of instrument analysis includes HPLC, IC, AAS, ICP, UV Vis, LC-MS, ICP-MS, etc;
Preparation of buffer and culture medium for cell culture;
Preparation of molecular biology reagents.
Preparation of standard solution and blank solution.
Nanomaterial science uses water, etc.


PURISTIntelligent Ultra Pure Water SystemPerformance indicators:

Water inlet requirements

Water inlet requirements

Purified water such as EDI water, RO water, distilled water, etc

inlet water temperature

5 - 35℃

inlet water pressure

0 - 0.1 MPa(0 - 1 bar)

UP water intake flow rate

0 - 2 L/min

UP waterElectrical resistivity (@ 25 ℃)

18.2 MΩ.cm

UP waterTotal Organic Carbon (TOC)*

≤ 2 ppb

UP waterParticles (>0.2 μ m)**

No particles with a diameter exceeding 0.22 μ m

UP waterMicroorganisms**

< 0.01 cfu/ml

UP waterPyrogen content***

< 0.001 Eu/ml

UP waterRNase***

< 0.5 pg/ml

UP waterDNase***

< 10 pg/ml

Overall dimensions of the host
Width x Depth x Height (cm)

32 X 44 X 54

External dimensions of the handle
Width x Depth x Height (cm)

21 X 29 X 61


*Under appropriate operating conditions; Otherwise, the usual value is less than 5 ppb

**Configure 0.2 μ m terminal filter or RephiBio filter