The Genie G intelligent EDI pure water ultra pure water integrated system integrates optimized flow path design, EDI module, and RephiLe formula packed ultra purification column, providing a comprehensive solution for laboratory water use. The water quality of the produced water (ultrapure water and EDI second grade pure water) meets or exceeds the Chinese laboratory water standards and test methods (GB 6682-2008) as well as the quality standards for first grade water and second grade water of ASTM, CLSI, and ISO3696, respectively.
Product Details

Genie GIntelligent EDI Pure Water Ultra Pure Water Integrated SystemInnovative features:

The main control screen, water dispenser system, and water intake handle can be wirelessly connected and placed as needed to save space; Remote control, remote diagnosis, reliable data transmission

High sensitivity touch screen, integrated buttons, durable and long-lasting, can carry water, and can be operated with latex gloves

Purification columns, RO columns, UV lamps, terminal filters, pumps and other consumable accessories are equipped with intelligent identification codes, which are scanned and recognized by the host for intelligent information management: real-time monitoring of working status, installation and maintenance signature confirmation, and full traceability. Convenient authentication

RephiBio terminal filter is used to prepare ultrapure water without pyrogens (endotoxins), nucleases, and bacteria for biochemical analysis and molecular biology

• Inlet conductivity detection


Pure water ultrapure water machineAdvantages and Characteristics:

• Total oxidation method online TOC detection system, online monitoring of TOC content in water

Adopting lonPure's EDI module, the performance is stable and the water quality is reliable. No need for chemical cleaning, reducing environmental pollution

RO and EDI produce water at a constant flow rate, unaffected by environmental temperature

Suitable for various terminal filters, and can choose ultra purification columns with different formula fillers - low magnesium type, low organic matter type, low boron type, ICP type, DI type, etc., to accurately meet the specific needs of users

The water tank comes with a stepless continuous liquid level detection, which allows you to check the water level and storage water quality on the main control screen; The water tank disinfection module effectively inhibits the growth of microorganisms

Optional water tank circulation upgrade component to maintain stable water quality in the water tank at 1 M Ω· cm or above

The system comes with a leak protection function, which automatically shuts down when there is a leak

Reserve 10 water intake handle interfaces, which can be added as needed

The water intake handle can view water quality information, adjust flow rate, and quantitatively intake water

The water handle is comfortable to hold, easy to operate with one hand, and convenient to use

The water intake handle bracket can be raised and lowered freely, with a 360 ° rotation and an anti slip base

The main control screen is an 8 'touch screen, which can complete all system settings, operations, and monitoring, and check the system status at any time, such as water leakage protection, disinfection module, etc

The main control screen can be read at the optimal angle and height, which is comfortable and convenient

The main control screen is moisture-proof, dustproof, wear-resistant, resistant to electromagnetic waves, and interference free

Purification column with high column capacity, optimized waterway design, high water flow rate, stable water quality

Purification column body pressure resistancestrongDouble sealed interface, low risk of water leakage

Tag, color, chip triple foolproof, installation of intelligent positioning


Main applications:

ultrapure water

EDI pure water

The supporting selection of instrument analysis includes HPLC, IC, AAS, ICP, UV Vis, LC-MS, ICP-MS, etc;
Preparation of buffer and culture medium for cell culture;
Preparation of molecular biology reagents;
Preparation of standard solution and blank solution;
Nanomaterial science uses water, etc.

Various experimental equipment (clinical biochemistry analyzer, cleaning machine, aging machine, high-pressure and high-temperature sterilizer, etc.) are filled with water;
Preparation of microbial culture medium and buffer solution;
Preparation of chemical and biochemical reagents;
Purified water for medicinal purposes;
The ultrapure water system is filled with water.


Genie GIntelligent EDI Pure Water Ultra Pure Water Integrated SystemPerformance indicators:

Water inlet requirements

Inlet conductivity/TDS

< 2000 μS/cm / < 1000 ppm

inlet water temperature

5 - 35℃

inlet water pressure

0.1 - 0.6 MPa (1 - 6 bar)

EDITechnical indicators for pure water

EDI aquaculture water flow rate

5,10,15 L/hr

EDI water intake flow rate

0 - 2 L/min

EDI water resistance rate (@ 25 ℃)

>5 M Ω. cm (typical value 10-16 M Ω. cm)

EDI water total organic carbon TOC

< 30 ppb

Technical indicators of ultrapure water

UP water intake flow rate

02 L/min

UP waterElectrical resistivity (@ 25 ℃)

18.2 MΩ.cm

UP waterTotal Organic Carbon (TOC)*

≤ 2 ppb

UP waterParticles (>0.2 μ m)**

No particles with a diameter exceeding 0.22 μ m

UP waterMicroorganisms**

< 0.01 cfu/ml

UP waterPyrogen content***

< 0.001 Eu/ml

UP waterDNase***

< 10 pg/ml

UP waterRNase***

< 0.5 pg/ml

Host dimensions: width x depth x height (cm)

32 X 44 X 54*Under appropriate operating conditions; Otherwise, the usual value is less than 5 ppb


*Under appropriate operating conditions; Otherwise, the usual value is less than 5 ppb

**Configure 0.2 μ m terminal filter or RephiBio filter